Virtual surgery to predict optimized conduit size for adult Fontan patients with 16-mm conduits

被引:7
作者
Hut, Tjerry [1 ,2 ]
Roest, Arno [3 ]
Gaillard, Duco [1 ,2 ]
Hazekamp, Mark [4 ]
van den Boogaard, Pieter [5 ]
Lamb, Hildo [5 ]
Kroft, Lucia [5 ]
Jongbloed, Monique [6 ]
Westenberg, Jos [5 ]
Wentzel, Jolanda [7 ]
Rijnberg, Friso [4 ,8 ]
Kenjeres, Sasa [1 ,2 ]
机构
[1] Delft Univ Technol, Fac Appl Sci, Dept Chem Engn, Delft, Netherlands
[2] JM Burgers Ctr Res Sch Fluid Mech, Delft, Netherlands
[3] Leiden Univ, Dept Pediat Cardiol, Med Ctr, Leiden, Netherlands
[4] Leiden Univ, Med Ctr, Dept Cardiothorac Surg, Leiden, Netherlands
[5] Leiden Univ, Med Ctr, Dept Radiol, Leiden, Netherlands
[6] Leiden Univ, Dept Cardiol & Anat & Embryol, Med Ctr, Leiden, Netherlands
[7] Erasmus MC, Dept Cardiol, Biomech Engn, Rotterdam, Netherlands
[8] Leiden Univ, Dept Cardiothorac Surg, Med Ctr, Albinusdreef 2, NL-2333 ZA Leiden, Netherlands
来源
INTERDISCIPLINARY CARDIOVASCULAR AND THORACIC SURGERY | 2023年 / 37卷 / 05期
关键词
Univentricular heart disease; Fontan circulation; Computational fluid dynamics; Extracardiac conduit; Total cavopulmonary connection; Energy loss; CARDIAC MAGNETIC-RESONANCE; CAVOPULMONARY CONNECTIONS; ENERGY-LOSS; EXERCISE; FLOW;
D O I
10.1093/icvts/ivad126
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: Recent evidence suggests that conduits implanted in Fontan patients at the age of 2-4 years become undersized for adulthood. The objective of this study is to use computational fluid dynamic models to evaluate the effect of virtual expansion of the Fontan conduit on haemodynamics and energetics of the total cavopulmonary connection (TCPC) under resting conditions and increased flow conditions.METHODS: Patient-specific, magnetic resonance imaging-based simulation models of the TCPC were performed during resting and increased flow conditions. The original 16-mm conduits were virtually enlarged to 3 new sizes. The proposed conduit sizes were defined based on magnetic resonance imaging-derived conduit flow in each patient. Flow efficiency was evaluated based on power loss, pressure drop and resistance and thrombosis risk was based on flow stagnation volume and relative residence time (RRT).RESULTS: Models of 5 adult patients with a 16-mm extracardiac Fontan connection were simulated and subsequently virtually expanded to 24-32 mm depending on patient-specific conduit flow. Virtual expansion led to a 40-65% decrease in pressure gradient across the TCPC depending on virtual conduit size. Despite improved energetics of the entire TCPC, the pulmonary arteries remained a significant contributor to energy loss (60-73% of total loss) even after virtual surgery. Flow stagnation volume inside the virtual conduit and surface area in case of elevated RRT (>20/Pa) increased after conduit enlargement but remained negligible (flow stagnation <2% of conduit volume in rest, <0.5% with exercise and elevated RRT <3% in rest, <1% with exercise).CONCLUSIONS: Virtual expansion of 16-mm conduits to 24-32 mm, depending on patient-specific conduit flow, in Fontan patients significantly improves TCPC efficiency while thrombosis risk presumably remains low.
引用
收藏
页数:10
相关论文
共 27 条
[1]   Optimal conduit size for extracardiac Fontan operation [J].
Alexi-Meskishvili, V ;
Ovroutski, S ;
Ewert, P ;
Dähnert, I ;
Berger, F ;
Lange, PE ;
Hetzer, R .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 18 (06) :690-695
[2]   An image-based modeling framework for patient-specific computational hemodynamics [J].
Antiga, Luca ;
Piccinelli, Marina ;
Botti, Lorenzo ;
Ene-Iordache, Bogdan ;
Remuzzi, Andrea ;
Steinman, David A. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (11) :1097-1112
[3]   Geometric Characterization of Patient-Specific Total Cavopulmonary Connections and its Relationship to Hemodynamics [J].
Beng, Elaine Tang ;
Restrepo, Maria ;
Haggerty, Christopher M. ;
Mirabella, Lucia ;
Bethel, James ;
Whitehead, Kevin K. ;
Fogel, Mark A. ;
Yoganathan, Ajit P. .
JACC-CARDIOVASCULAR IMAGING, 2014, 7 (03) :215-224
[4]   A comprehensive comparison of various patient-specific CFD models of the left atrium for atrial fibrillation patients [J].
Duenas-Pamplona, Jorge ;
Garcia Garcia, Javier ;
Sierra-Pallares, Jose ;
Ferrera, Conrado ;
Agujetas, Rafael ;
Lopez-Minguez, Jose Ramon .
COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 133
[5]   ANGIOCARDIOGRAPHIC MEASUREMENT OF CARDIAC SEGMENT OF INFERIOR VENA CAVA IN HEALTH AND IN CARDIOVASCULAR DISEASE [J].
ETTINGER, E ;
STEINBERG, I .
CIRCULATION, 1962, 26 (04) :508-&
[6]   Thrombosis and Thromboembolic Complications in Fontan Patients: A Literature Review [J].
Firdouse, Mohammed ;
Agarwal, Arnav ;
Chan, Anthony K. ;
Mondal, Tapas .
CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2014, 20 (05) :484-492
[7]   Hemodynamic variables in aneurysms are associated with thrombotic risk in children with Kawasaki disease [J].
Gutierrez, Noelia Grande ;
Mathew, Mathew ;
McCrindle, BrianW. ;
Tran, Justin S. ;
Kahn, Andrew M. ;
Burns, Jane C. ;
Marsden, Alison L. .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 281 :15-21
[8]   Fontan hemodynamics from 100 patient-specific cardiac magnetic resonance studies: A computational fluid dynamics analysis [J].
Haggerty, Christopher M. ;
Restrepo, Maria ;
Tang, Elaine ;
de Zelicourt, Diane A. ;
Sundareswaran, Kartik S. ;
Mirabella, Lucia ;
Bethel, James ;
Whitehead, Kevin K. ;
Fogel, Mark A. ;
Yoganathan, Ajit P. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (04) :1481-1489
[9]   Effects of exercise and respiration on blood flow in total cavopulmonary connection -: A real-time magnetic resonance flow study [J].
Hjortdal, VE ;
Emmertsen, K ;
Stenbog, E ;
Fründ, T ;
Schmidt, MR ;
Kromann, O ;
Sorensen, K ;
Pedersen, EM .
CIRCULATION, 2003, 108 (10) :1227-1231
[10]   Optimal Conduit Size of the Extracardiac Fontan Operation Based on Energy Loss and Flow Stagnation [J].
Itatani, Keiichi ;
Miyaji, Kagami ;
Tomoyasu, Takahiro ;
Nakahata, Yayoi ;
Ohara, Kuniyoshi ;
Takamoto, Shinichi ;
Ishii, Masahiro .
ANNALS OF THORACIC SURGERY, 2009, 88 (02) :565-573