Comparing nanobody and aptamer-based capacitive sensing for detection of interleukin-6 (IL-6) at physiologically relevant levels

被引:22
|
作者
Sanchez-Salcedo, Raquel [1 ,2 ,3 ]
Miranda-Castro, Rebeca [1 ,2 ]
de-los-Santos-Alvarez, Noemi [1 ,2 ]
Lobo-Castanon, Maria Jesus [1 ,2 ]
Corrigan, Damion K. [3 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Av Julian Claveria 8, Oviedo 33006, Spain
[2] Inst Invest Sanitaria Principado Asturias, Av Roma, Oviedo 33011, Spain
[3] Univ Strathclyde, Dept Pure & Appl Chem, Thomas Graham Bldg,295 Cathedral St, Glasgow G1 1XL, Scotland
关键词
Capacitive impedance spectroscopy; Electrochemical biosensing; Interleukin-6; Immunosensors; Aptasensors; DNA; IMMOBILIZATION;
D O I
10.1007/s00216-023-04973-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A major societal challenge is the development of the necessary tools for early diagnosis of diseases such as cancer and sepsis. Consequently, there is a concerted push to develop low-cost and non-invasive methods of analysis with high sensitivity and selectivity. A notable trend is the development of highly sensitive methods that are not only amenable for point-of-care (POC) testing, but also for wearable devices allowing continuous monitoring of biomarkers. In this context, a non-invasive test for the detection of a promising biomarker, the protein Interleukin-6 (IL-6), could represent a significant advance in the clinical management of cancer, in monitoring the chemotherapy response, or for prompt diagnosis of sepsis. This work reports a capacitive electrochemical impedance spectroscopy sensing platform tailored towards POC detection and treatment monitoring in human serum. The specific recognition of IL-6 was achieved employing gold surfaces modified with an anti-IL6 nanobody (anti-IL-6 VHH) or a specific IL-6 aptamer. In the first system, the anti-IL-6 VHH was covalently attached to the gold surface using a binary self-assembled-monolayer (SAM) of 6-mercapto-1-hexanol (MCH) and 11-mercaptoundecanoic acid. In the second system, the aptamer was chemisorbed onto the surface in a mixed SAM layer with MCH. The analytical performance for each label-free sensor was evaluated in buffer and 10% human serum samples and then compared. The results of this work were generated using a low-cost, thin film eight-channel gold sensor array produced on a flexible substrate providing useful information on the future design of POC and wearable impedance biomarker detection platforms.
引用
收藏
页码:7035 / 7045
页数:11
相关论文
共 50 条