Graphene oxide-based colorimetric/fluorescence dual-mode immunochromatography assay for simultaneous ultrasensitive detection of respiratory virus and bacteria in complex samples

被引:35
作者
Cheng, Xiaodan [1 ,2 ]
Yang, Xingsheng [1 ,2 ]
Tu, Zhijie [1 ,2 ]
Rong, Zhen [1 ,2 ]
Wang, Chongwen [2 ,3 ]
Wang, Shengqi [1 ,2 ]
机构
[1] Bioinformat Ctr AMMS, Beijing 100850, Peoples R China
[2] Beijing Key Lab New Mol Diag Technol Infect Dis, Beijing 100850, Peoples R China
[3] Southern Med Univ, Guangdong Prov Peoples Hosp, Guangdong Acad Med Sci, Dept Clin Lab Med, Guangzhou 510000, Guangdong, Peoples R China
关键词
Influenza A; Streptococcus pneumoniae; Film-like dual-signal nanotag; Colorimetric; fluorescence dual mode; Immunochromatography assay; LATERAL FLOW IMMUNOASSAY; RAPID DETECTION; SARS-COV-2; PLATFORM; ACID;
D O I
10.1016/j.jhazmat.2023.132192
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A point-of-care testing biosensor that supports direct, sensitive, and simultaneous identification of bacteria and virus is still lacking. In this study, an ultrasensitive immunochromatography assay (ICA) with colorimetric/ fluorescence dual-signal output was proposed for flexible and accurate detection of respiratory virus and bacteria in complex samples. Colorimetric AuNPs of 16 nm and two layers of quantum dots (QDs) were coated onto the surface of monolayer graphene oxide (GO) layer by layer to form a multilayered dual-signal nanofilm. This material not only can generate strong colorimetric and fluorescence signals for ICA analysis but also can provide larger surface area, better stability, and superior dispersibility than conventional spherical nanomaterials. Two test lines were built onto the ICA strip to simultaneously detect common respiratory virus influenza A and respiratory bacteria Streptococcus pneumoniae. The dual-signal mode of assay greatly broadened the applied range of ICA method, in which the colorimetric mode allows for quick determination of virus/bacteria and the fluo-rescence mode ensures the highly sensitive and quantitative detection of target pathogens with detection limits down to 891 copies/mL and 17 cells/mL, respectively. The proposed dual-mode ICA can also be applied directly for real biological and environment samples, which suggests its great potential for field application.
引用
收藏
页数:11