Evolution of the theoretical description of the isoelectric focusing experiment: II. An open system isoelectric focusing experiment is a transient, bidirectional isotachophoretic experiment

被引:3
|
作者
Vigh, Gyula [1 ,3 ]
Gas, Bohuslav [2 ]
机构
[1] Texas A&M Univ, Chem Dept, College Stn, TX USA
[2] Charles Univ Prague, Fac Sci, Prague, Czech Republic
[3] POB 1235, Gold Beach, OR 97444 USA
关键词
isoelectric focusing; simulation; transient bidirectional isotachophoresis; CAPILLARY-ZONE-ELECTROPHORESIS; BACKGROUND ELECTROLYTES; LINEAR-THEORY; HYDROGEN-ION; EIGENMOBILITIES; SEPARATION;
D O I
10.1002/elps.202200238
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The carrier ampholytes-based (CA-based) isoelectric focusing (IEF) experiment evolved from Svensson's closed system IEF (constant spatial current density, absence of convective mixing, counter-balancing electrophoretic and diffusive fluxes yielding a steady state pH gradient) to the contemporary open system IEF (absence of convective mixing, large cross-sectional area electrode vessels, lack of counter-balancing electrophoretic- and diffusive fluxes leading to transient pH gradients). Open system IEF currently is described by a two-stage model: In the first stage, a rapid IEF process forms the pH gradient which, in the second stage, is slowly degraded by isotachophoretic processes that move the most acidic and most basic CAs into the electrode vessels. An analysis of the effective mobilities and the effective mobility to conductivity ratios of the anolyte, catholyte, and the CAs indicates that in open system IEF experiments a single process, transient bidirectional isotachophoresis (tbdITP) operates from the moment current is turned on until it is turned off. In tbdITP, the anolyte and catholyte provide the leading ions and the pI 7 CA or the reactive boundary of the counter-migrating H3O+ and OH- ions serves as the shared terminator. The outcome of the tbdITP process is determined by the ionic mobilities, pK(a) values, and loaded amounts of all ionic and ionizable components: It is constrained by both the transmitted amount of charge and the migration space available for the leading ions. tbdITP and the resulting pH gradient can never reach steady state with respect to the spatial coordinate of the separation channel.
引用
收藏
页码:675 / 688
页数:14
相关论文
共 31 条
  • [1] Evolution of the theoretical description of the isoelectric focusing experiment: III. Carrier ampholyte behavior in transient, bidirectional isotachophoresis
    Vigh, Gyula
    Gas, Bohuslav
    ELECTROPHORESIS, 2023, 44 (7-8) : 689 - 700
  • [2] Evolution of the theoretical description of the isoelectric focusing experiment: I. The path from Svensson's steady-state model to the current two-stage model of isoelectric focusing
    Vigh, Gyula
    Gas, Bohuslav
    ELECTROPHORESIS, 2023, 44 (7-8) : 667 - 674
  • [3] Using a Simple, Inexpensive Undergraduate Isoelectric Focusing Experiment for Proteins and Nanomolecules To Help Students Understand Isoelectric Point and Its Real-World Applications
    Sharma, A.
    Kopkau, H.
    Swanson, D.
    JOURNAL OF CHEMICAL EDUCATION, 2018, 95 (09) : 1654 - 1657
  • [4] Moving chemical reaction boundary and isoelectric focusing - II. Existence of quasi/equal fluxes (or transference numbers) of hydrogen and hydroxyl ions in stationary electrolysis and Svensson's isoelectric focusing
    Cao, CX
    JOURNAL OF CHROMATOGRAPHY A, 1998, 813 (01) : 173 - 177
  • [5] Application of focusing schlieren visualization system in shock tunnel experiment
    Xu, Xiang
    Xie, Ai-Min
    Lü, Zhi-Guo
    Song, Qiang
    Huang, Jie
    Shiyan Liuti Lixue/Journal of Experiments in Fluid Mechanics, 2009, 23 (03): : 75 - 79
  • [6] Studies of a Proximity Focusing RICH with Aerogel Radiator for Belle II Experiment
    Hara, K.
    Adachi, I.
    Dolenec, R.
    Iijima, T.
    Imamura, M.
    Iwata, S.
    Kawai, H.
    Korpar, S.
    Krizan, P.
    Kumita, T.
    Kuroda, E.
    Nishida, S.
    Ogawa, S.
    Pestotnik, R.
    Shiizuka, S.
    Sumiyoshi, T.
    Tabata, M.
    Tagai, S.
    Verheyden, R.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 415 - 419
  • [7] Evaluation of sample fractionation using micro-scale liquid-phase isoelectric focusing on mass spectrometric identification and quantitation of proteins in a SILAC experiment
    Thorsell, Annika
    Portelius, Erik
    Blennow, Kaj
    Westman-Brinkmalm, Ann
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (05) : 771 - 778
  • [8] Focusing horn system for the BNL very long baseline neutrino oscillation experiment
    Kahn, SA
    Carroll, A
    Diwan, MV
    Gallardo, JC
    Kirk, H
    Scarlett, C
    Simos, N
    Viren, B
    Zhang, W
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 3255 - 3257
  • [9] MINI ISOELECTRIC-FOCUSING DEVICE TO BE USED WITH THE BIO-RAD MINI-PROTEAN-II SYSTEM
    WONG, VWT
    NARUSE, K
    PHANG, SM
    ANALYTICAL BIOCHEMISTRY, 1993, 212 (01) : 299 - 301
  • [10] ELECTRON MODEL EXPERIMENT TO STUDY INSTABILITIES IN LONG PERIODIC FOCUSING SYSTEM FOR INTENSE BEAMS
    REISER, M
    NAMKUNG, W
    BRENNAN, MA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (02): : 143 - 144