Value of adding ultrathin bronchoscopy to thin bronchoscopy for peripheral pulmonary lesions: A multicentre prospective study

被引:14
作者
Oki, Masahide [1 ]
Saka, Hideo [1 ]
Himeji, Daisuke [2 ]
Imabayashi, Tatsuya [3 ]
Nishii, Yoichi [4 ]
Ando, Masahiko [5 ]
机构
[1] Natl Hosp Org Nagoya Med Ctr, Dept Resp Med, Nagoya, Aichi, Japan
[2] Miyazaki Prefectural Miyazaki Hosp, Dept Internal Med, Miyazaki, Japan
[3] Kyoto Prefectural Univ Med, Grad Sch Med Sci, Dept Pulm Med, Kyoto, Japan
[4] Matsusaka Municipal Hosp, Resp Ctr, Matsusaka, Japan
[5] Nagoya Univ Hosp, Ctr Adv Med & Clin Res, Nagoya, Aichi, Japan
关键词
bronchoscopy; endobronchial ultrasound; peripheral pulmonary lesion; ultrathin bronchoscope; RADIAL ENDOBRONCHIAL ULTRASOUND; GUIDED TRANSBRONCHIAL BIOPSY; LUNG-CANCER DIAGNOSIS; ULTRASONOGRAPHY; SHEATH; YIELD; INCREASES;
D O I
10.1111/resp.14397
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background and Objective The diagnostic yield of thin bronchoscopy with radial probe endobronchial ultrasound (rEBUS) of peripheral pulmonary lesions into which the rEBUS probe cannot be inserted is unsatisfactory. In such cases, adding ultrathin bronchoscopy may be an option. We evaluated the efficacy of sequential ultrathin bronchoscopy for peripheral pulmonary lesions into which the rEBUS probe could not be inserted during thin bronchoscopy. Methods In this multicentre prospective study, patients with peripheral pulmonary lesions <= 30 mm in diameter underwent rEBUS-guided transbronchial biopsy using a 4.0 mm diameter thin bronchoscope. In patients with lesions into which a rEBUS probe could not be inserted using that bronchoscope, bronchoscopy using a 3.0 mm diameter ultrathin bronchoscope was performed. Results A total of 342 patients were enrolled and 340 were analysed. Among them, 87 patients with lesions of a median longest diameter of 17.5 mm underwent thin bronchoscopy followed by ultrathin bronchoscopy. Of the 87 patients, the rEBUS probe was successfully inserted into the lesions via the ultrathin bronchoscope in 50 patients (57.5%). Of the 87 patients, the diagnostic yields of thin bronchoscopy and ultrathin bronchoscopy were 12.6% (11 of 87) and 41.4% (36 of 87), respectively (p < 0.001). Conclusion Ultrathin bronchoscopy affords a higher diagnostic yield for lesions into which a rEBUS probe cannot be inserted via a thin bronchoscope.
引用
收藏
页码:152 / 158
页数:7
相关论文
共 29 条
[11]   Suitability of Bronchoscopic Biopsy Tissue Samples for Next-Generation Sequencing [J].
Murakami, Shuji ;
Yokose, Tomoyuki ;
Nemoto, Daiji ;
Suzuki, Masaki ;
Usui, Ryou ;
Nakahara, Yoshiro ;
Kondo, Tetsuro ;
Kato, Terufumi ;
Saito, Haruhiro .
DIAGNOSTICS, 2021, 11 (03)
[12]   Use of Ultrathin Bronchoscope on a Need Basis Improves Diagnostic Yield of Difficult-to-Approach Pulmonary Lesions [J].
Nishii, Yoichi ;
Nakamura, Yuki ;
Fujiwara, Kentaro ;
Ito, Kentaro ;
Sakaguchi, Tadashi ;
Suzuki, Yuta ;
Furuhashi, Kazuki ;
Kobayashi, Tetsu ;
Yasuma, Taro ;
D'Alessandro-Gabazza, Corina N. ;
Gabazza, Esteban C. ;
Asano, Fumihiro ;
Taguchi, Osamu ;
Hataji, Osamu .
FRONTIERS IN MEDICINE, 2020, 7
[13]   Factors leading to failure to diagnose pulmonary malignant tumors using endobronchial ultrasound with guide sheath within the target lesion [J].
Nishii, Yoichi ;
Yasuma, Taro ;
Ito, Kentaro ;
Suzuki, Yuta ;
Watanabe, Fumiaki ;
Kobayashi, Tetsu ;
Nishihama, Kota ;
D'Alessandro-Gabazza, Corina N. ;
Fujimoto, Hajime ;
Gabazza, Esteban C. ;
Asano, Fumihiro ;
Taguchi, Osamu ;
Hataji, Osamu .
RESPIRATORY RESEARCH, 2019, 20 (01)
[14]   Factors Affecting the Diagnostic Yield of Transbronchial Biopsy Using Endobronchial Ultrasonography with a Guide Sheath in Peripheral Lung Cancer [J].
Okachi, Shotaro ;
Imai, Naoyuki ;
Imaizumi, Kazuyoshi ;
Iwano, Shingo ;
Ando, Masahiko ;
Hase, Tetsunari ;
Aso, Hiromichi ;
Morise, Masahiro ;
Wakahara, Keiko ;
Ito, Satoru ;
Hashimoto, Naozumi ;
Sato, Mitsuo ;
Kondo, Masashi ;
Hasegawa, Yoshinori .
INTERNAL MEDICINE, 2016, 55 (13) :1705-1712
[15]   Guide sheath versus non-guide sheath method for endobronchial ultrasound-guided biopsy of peripheral pulmonary lesions: a multicentre randomised trial [J].
Oki, Masahide ;
Saka, Hideo ;
Imabayashi, Tatsuya ;
Himeji, Daisuke ;
Nishii, Yoichi ;
Nakashima, Harunori ;
Minami, Daisuke ;
Okachi, Shotaro ;
Mizumori, Yasuyuki ;
Ando, Masahiko .
EUROPEAN RESPIRATORY JOURNAL, 2022, 59 (05)
[16]   Diagnostic value of ultrathin bronchoscopy in peripheral pulmonary lesions: a narrative review [J].
Oki, Masahide ;
Saka, Hideo .
JOURNAL OF THORACIC DISEASE, 2020, 12 (12) :7675-7682
[17]   Use of an Ultrathin vs Thin Bronchoscope for Peripheral Pulmonary Lesions A Randomized Trial [J].
Oki, Masahide ;
Saka, Hideo ;
Asano, Fumihiro ;
Kitagawa, Chiyoe ;
Kogure, Yoshihito ;
Tsuzuku, Akifumi ;
Ando, Masahiko .
CHEST, 2019, 156 (05) :954-964
[18]   Ultrathin Bronchoscopy with Multimodal Devices for Peripheral Pulmonary Lesions A Randomized Trial [J].
Oki, Masahide ;
Sakai, Hideo ;
Ando, Masahiko ;
Asano, Fumihiro ;
Kurimoto, Noriaki ;
Morita, Katsuhiko ;
Kitagawa, Chiyoe ;
Kogure, Yoshihito ;
Miyazawa, Teruomi .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 192 (04) :468-476
[19]   Randomized Study of Endobronchial Ultrasound-Guided Transbronchial Biopsy Thin Bronchoscopic Method versus Guide Sheath Method [J].
Oki, Masahide ;
Saka, Hideo ;
Kitagawa, Chiyoe ;
Kogure, Yoshihito ;
Murata, Naohiko ;
Adachi, Takashi ;
Ando, Masahiko .
JOURNAL OF THORACIC ONCOLOGY, 2012, 7 (03) :535-541
[20]   Diagnostic yield of additional conventional transbronchial lung biopsy following radial endobronchial ultrasound lung biopsy for peripheral pulmonary lesions [J].
Park, Sojung ;
Yoon, Hee-Young ;
Han, Yeji ;
Wang, Kyung Sook ;
Park, So Young ;
Ryu, Yon Ju ;
Lee, Jin Hwa ;
Chang, Jung Hyun .
THORACIC CANCER, 2020, 11 (06) :1639-1646