Accuracy of Intraocular Lens Power Calculation Formulas in Patients With Multifocal Intraocular Lens Implantation With Optic Capture in Berger Space for Pediatric Cataract

被引:4
|
作者
Wang, Menghan [1 ,2 ]
Li, Dongfang [2 ,3 ]
Fan, Zheng [1 ,2 ]
Zhang, Jing [2 ,3 ]
Zhou, Jinyan [2 ,3 ]
Huang, Yusen [2 ,3 ]
机构
[1] Qingdao Univ, Coll Med, Qingdao, Peoples R China
[2] Shandong First Med Univ, State Key Lab Cultivat Base, Shandong Prov Key Lab Ophthalmol, Eye Inst, Qingdao, Peoples R China
[3] Shandong First Med Univ, Qingdao Eye Hosp, Qingdao, Peoples R China
基金
中国国家自然科学基金;
关键词
PREDICTION FORMULAS; MYOPIC SHIFT; AXIAL LENGTH; VISUAL AXIS; SURGERY; ERROR; CAPSULORHEXIS; OPACIFICATION; PSEUDOPHAKIA; BIOMETRY;
D O I
10.3928/01913913-20220428-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the accuracy of intraocular lens (IOL) calculation formulas in pediatric patients with multifocal IOL implantation with optic capture in Berger space. Methods:This prospective observational study enrolled 68 children (101 eyes), aged 3 to 14 years, who received multifocal IOL (Tecnis ZMB00; Abbott Medical Optics) implantation with optic capture in Berger space from June 2019 to June 2020 in Qingdao Eye Hospital. Ocular biometry was performed using the IOLMaster 700 (Carl Zeiss Meditec). The IOL power and intended postoperative refraction were calculated using the Hoffer Q, Barrett Universal II, Holladay, Holladay2, SRK/T, Haigis, and SRKII formulas. The refractive state of patients, prediction error, and absolute prediction error were evaluated. Results: The mean absolute error of the formulas was significantly different (0.49 diopters [D], Hoffer Q; 0.52 D, Barrett Universal II; 0.47 D, Holladay; 0.54 D, Holladay2; 0.52 D, SRK/T; 0.67 D, Haigis; 0.99 D, SRKII; P < .001). However, the Hoffer Q, Barrett Universal II, Holladay, Holladay2, and SRK/T formulas had a similar accuracy in predicting refractive error within +/- 0.50 D (62.4%, 59.4%, 62.4%, 62.4%, and 58.4%). There was a trend toward a greater prediction error in eyes with a shorter axial length (<= 22 mm) or a steeper cornea (> 43.50 D), for which the Hoffer Q and Holladay2 formulas were more accurate. When the axial length was greater than 22 mm or the corneal curvature was 43.50 D or less, the Holladay, Hoffer Q, and Barrett Universal II formulas were more accurate. Conclusions: For patients with pediatric cataract treated with multifocal IOL implantation with optic capture in Berger space, the Hoffer Q, Barrett Universal II, Holladay, Holladay2, and SRK/T formulas performed better than the other formulas.
引用
收藏
页码:139 / +
页数:9
相关论文
共 50 条
  • [31] Comparison of the accuracy of three intraocular lens power calculation formulas in cataract patients with prior radial keratotomy
    Meng Li
    Jin-Da Wang
    Jing-Shang Zhang
    Ying-Yan Mao
    Kai Cao
    Xiu-Hua Wan
    European Journal of Medical Research, 28
  • [32] Accuracy of a universal theoretical formula for power calculation in pediatric intraocular lens implantation
    Eppley, Sarah E.
    Arnold, Benjamin F.
    Tadros, Dina
    Pasricha, Neel
    Campomanes, Alejandra G. de Alba
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (05): : 599 - 605
  • [33] Accuracy of intraocular lens power calculation in paediatric cataract surgery
    Tromans, C
    Haigh, PM
    Biswas, S
    Lloyd, IC
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (08) : 939 - 941
  • [34] Posterior optic capture of intraocular lens in difficult cases of pediatric cataract
    Sukhija, Jaspreet
    Kaur, Savleen
    Korla, Shagun
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (01) : 293 - 295
  • [35] Posterior capsulorhexis with optic capture in pediatric cataract and intraocular lens surgery
    Gimbel, HV
    OPHTHALMOLOGY, 1996, 103 (11) : 1871 - 1875
  • [36] Late intraocular lens exchange in dissatisfied patients with multifocal intraocular lens implantation
    Kuo, Yu-Wei
    Hou, Yu-Chih
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2022, 12 (01) : 109 - 112
  • [37] Microincision cataract surgery with implantation of a bitoric intraocular lens using an enhanced program for intraocular lens power calculation
    Lesieur, Gilles
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (06) : 1308 - 1313
  • [38] Accuracy of biometry in pediatric cataract extraction with primary intraocular lens implantation
    Moore, Daniel B.
    Ben Zion, Itay
    Neely, Daniel E.
    Plager, David A.
    Offier, Susan
    Sprunger, Derek T.
    Roberts, Gavin J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11): : 1940 - 1947
  • [39] Our Results of Accommodative and Multifocal Intraocular Lens Implantation in Patients with Cataract
    Suzan, Guven Yilmaz
    Rose, Suheyla
    Palamar, Metis
    Egrilmez, Sait
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2009, 39 (01): : 4 - 16
  • [40] Screening for multifocal intraocular lens implantation in cataract patients in a public hospital
    Halkiadakis, Ioannis
    Ntravalias, Thomas
    Kollia, Elpida
    Chatzistefanou, Klio
    Kandarakis, Stylianos A.
    Patsea, Eleni
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)