Accuracy of Intraocular Lens Power Calculation Formulas in Patients With Multifocal Intraocular Lens Implantation With Optic Capture in Berger Space for Pediatric Cataract

被引:3
|
作者
Wang, Menghan [1 ,2 ]
Li, Dongfang [2 ,3 ]
Fan, Zheng [1 ,2 ]
Zhang, Jing [2 ,3 ]
Zhou, Jinyan [2 ,3 ]
Huang, Yusen [2 ,3 ]
机构
[1] Qingdao Univ, Coll Med, Qingdao, Peoples R China
[2] Shandong First Med Univ, State Key Lab Cultivat Base, Shandong Prov Key Lab Ophthalmol, Eye Inst, Qingdao, Peoples R China
[3] Shandong First Med Univ, Qingdao Eye Hosp, Qingdao, Peoples R China
基金
中国国家自然科学基金;
关键词
PREDICTION FORMULAS; MYOPIC SHIFT; AXIAL LENGTH; VISUAL AXIS; SURGERY; ERROR; CAPSULORHEXIS; OPACIFICATION; PSEUDOPHAKIA; BIOMETRY;
D O I
10.3928/01913913-20220428-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the accuracy of intraocular lens (IOL) calculation formulas in pediatric patients with multifocal IOL implantation with optic capture in Berger space. Methods:This prospective observational study enrolled 68 children (101 eyes), aged 3 to 14 years, who received multifocal IOL (Tecnis ZMB00; Abbott Medical Optics) implantation with optic capture in Berger space from June 2019 to June 2020 in Qingdao Eye Hospital. Ocular biometry was performed using the IOLMaster 700 (Carl Zeiss Meditec). The IOL power and intended postoperative refraction were calculated using the Hoffer Q, Barrett Universal II, Holladay, Holladay2, SRK/T, Haigis, and SRKII formulas. The refractive state of patients, prediction error, and absolute prediction error were evaluated. Results: The mean absolute error of the formulas was significantly different (0.49 diopters [D], Hoffer Q; 0.52 D, Barrett Universal II; 0.47 D, Holladay; 0.54 D, Holladay2; 0.52 D, SRK/T; 0.67 D, Haigis; 0.99 D, SRKII; P < .001). However, the Hoffer Q, Barrett Universal II, Holladay, Holladay2, and SRK/T formulas had a similar accuracy in predicting refractive error within +/- 0.50 D (62.4%, 59.4%, 62.4%, 62.4%, and 58.4%). There was a trend toward a greater prediction error in eyes with a shorter axial length (<= 22 mm) or a steeper cornea (> 43.50 D), for which the Hoffer Q and Holladay2 formulas were more accurate. When the axial length was greater than 22 mm or the corneal curvature was 43.50 D or less, the Holladay, Hoffer Q, and Barrett Universal II formulas were more accurate. Conclusions: For patients with pediatric cataract treated with multifocal IOL implantation with optic capture in Berger space, the Hoffer Q, Barrett Universal II, Holladay, Holladay2, and SRK/T formulas performed better than the other formulas.
引用
收藏
页码:139 / +
页数:9
相关论文
共 50 条
  • [1] Observation on the tilt and decentration of multifocal intraocular lens with optic capture in Berger space for pediatric cataract
    Fan, Zheng
    Wang, Menghan
    Peng, Yusu
    Wang, Xiaoyun
    Li, Dongfang
    Ding, Yichao
    Zhang, Jing
    Huang, Yusen
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [2] Accuracy of 8 intraocular lens power calculation formulas in pediatric cataract patients
    Chang, Pingjun
    Lin, Lei
    Li, Zhangliang
    Wang, Li
    Huang, Jinhai
    Zhao, Yun-e
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (05) : 1123 - 1131
  • [3] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Zhao, Jing
    Liu, Liang-Ping
    Cheng, Huan-Huan
    Li, Jian-Bing
    Han, Xiao-Tong
    Liu, Yu
    Wu, Ming-Xing
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (09) : 1378 - 1384
  • [4] Accuracy of Intraocular lens power calculation in pediatric traumatic cataract
    Goyal, Priya
    Tibrewal, Shailja
    Ganesh, Suma
    Rath, Soveeta
    Majumdar, Atanu
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (11) : 1605 - 1610
  • [5] Accuracy of newer generation intraocular lens power calculation formulas in pediatric cataract patients
    Lin, Lei
    Fang, Jiayan
    Sun, Weijie
    Gu, Siyi
    Xu, Liming
    Chen, Siping
    Chang, Pingjun
    Zhao, Yun-e
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (04) : 1019 - 1027
  • [6] Accuracy of intraocular lens calculation formulas in cataract patients with steep corneal curvature
    Zhang, Chenguang
    Dai, Guangzheng
    Pazo, Emmanuel Eric
    Xu, Ling
    Wu, Xianwei
    Zhang, Hongda
    Lin, Tiezhu
    He, Wei
    PLOS ONE, 2020, 15 (11):
  • [7] Refractive accuracy after intraocular lens implantation in pediatric cataract
    Long, Tan
    Huang, Yu-Sen
    Xie, Li-Xin
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2012, 5 (04) : 473 - 477
  • [8] Accuracy of Intraocular Lens Power Calculation Formulas in Pediatric Cataract Patients: A Systematic Review and Meta-Analysis
    Zhong, Yueyang
    Yu, Yibo
    Li, Jinyu
    Lu, Bing
    Li, Su
    Zhu, Yanan
    FRONTIERS IN MEDICINE, 2021, 8
  • [9] Intraocular lens optic capture in pediatric cataract surgery
    Xie, Ying-Bin
    Ren, Mei-Yu
    Wang, Qi
    Wang, Li-Hua
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2018, 11 (08) : 1403 - 1410
  • [10] Intraocular lens optic capture in pediatric cataract surgery
    Ying-Bin Xie
    Mei-Yu Ren
    Qi Wang
    Li-Hua Wang
    International Journal of Ophthalmology, 2018, (08) : 1403 - 1410