Fire resistance of steel reinforced reactive powder concrete columns

被引:4
作者
Wang, Yuzhuo [1 ,2 ]
Guo, Liwei [1 ]
Wang, Rui [3 ,4 ]
Xu, Tiangui [5 ]
机构
[1] Shandong Jianzhu Univ, Sch Civil Engn, Jinan 250101, Shandong, Peoples R China
[2] Shandong Jianzhu Univ, Key Lab Bldg Struct Retrofitting & Underground Spa, Minist Educ, Jinan 250101, Shandong, Peoples R China
[3] Shandong Acad Bldg Sci Co Ltd, Jinan 250031, Shandong, Peoples R China
[4] Shandong Luneng Intelligence Technol Co Ltd, Jinan, Shandong, Peoples R China
[5] Southeast Univ, Sch Civil Engn, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, Jiulonghu Campus, Nanjing 211189, Peoples R China
基金
中国国家自然科学基金;
关键词
Steel Reinforced Reactive Powder Concrete; (SRRPC); Failure mechanism; Fire resistance; Finite element mode; Simplified calculation formula; HIGH-TEMPERATURE; PERFORMANCE; FIBERS;
D O I
10.1016/j.istruc.2023.105238
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel reinforced reactive powder concrete (SRRPC) columns have been widely used in structures due to their excellent mechanical properties. However, owing to inadequate experimental data and a lack of design basis for SRRPC columns at high temperatures, which limits the application and development of this structure in practical engineering. Five SRRPC columns with different loads were experimentally investigated at high temperatures. Additionally, 15 sets of specimens were analyzed by using numerical simulation method of thermo-mechanical coupling, and the rules of steel ratio, rebar ratio, and number of heating surfaces on the fire resistance of SRRPC columns were obtained. The test results revealed that the fire resistance decreased by 52.7% when the axial compression ratio increased from 0.2 to 0.6; The fire resistance increased by 17.79% when the steel ratio increased from 4.08% to 10.21%; The fire resistance increased by 3.24% when the rebar ratio increased from 0.83% to 2.76%; The fire resistance decreased by 28.95% when the number of heating surfaces increased from single-face heating to four-face heating. According to the variation rule of each parameter, the correlation degree of each parameter on the fire resistance was obtained, it concluded that the axial compression ratio had the highest correlation degree, followed by the number of heating surfaces, while the correlation degrees of steel ratio and rebar ratio were relatively small. A formula was proposed to predict the fire resistance of SRRPC columns, which can provide a reference for fire resistance evaluation, repair and reinforcement of SRRPC structures in fire.
引用
收藏
页数:16
相关论文
共 45 条
  • [1] Mechanical properties of steel fiber-reinforced reactive powder concrete at high temperature and after cooling
    Abid, Muhammad
    Hou, Xiaomeng
    Zheng, Wenzhong
    Waqar, Gliulam Qadir
    [J]. PERFORMANCE OF MATERIALS AND STRUCTURES UNDER EXTREME CONDITIONS, 2017, 210 : 597 - 604
  • [2] Influence of Steel Fibres on the Behaviour of RPC Circular Columns Under Different Loading Conditions
    Al-Tikrite, Ahmed
    Hadi, Muhammad N. S.
    [J]. STRUCTURES, 2018, 14 : 111 - 123
  • [3] [Anonymous], 2016, 1382016 JGJ
  • [4] [Anonymous], 2010, GB/T 25282-2010
  • [5] [Anonymous], 2008, 997812008 GBT
  • [6] [Anonymous], 2010, Code for design of concrete structures
  • [7] [Anonymous], 2015, 313872015 GBT
  • [8] Bu LT, 2017, J Nat Sci Xiangtan Univ, V39, P18, DOI [10.13715/j.cnki.nsjxu.2017.03.005, DOI 10.13715/J.CNKI.NSJXU.2017.03.005]
  • [9] Impact of elevated temperatures on the behavior and microstructure of reactive powder concrete
    Chadli, Mounira
    Tebbal, Nadia
    Mellas, Mekki
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2021, 300
  • [10] Chen W., 2017, Sci. Technol. Eng., V17, P306