The Accuracy of Velocity-Time Integral Variation and Peak Velocity Variation of the Left Ventricular Outflow Tract in Predicting Fluid Responsiveness in Postoperative Patients Mechanically Ventilated at Low Tidal Volumes

被引:6
作者
Xie, Jin [1 ]
Wan, Jingjie [2 ]
Xu, Li [1 ]
Zhang, Yukun [1 ]
Chen, Jun [1 ,3 ]
机构
[1] Soochow Univ, Dept Anesthesiol, Affiliated Hosp 1, Intens Care Unit, Suzhou, Peoples R China
[2] Soochow Univ, Dept Anesthesiol, Affiliated Hosp 1, Suzhou, Peoples R China
[3] Soochow Univ, Dept Anesthesiol, Affiliated Hosp 1, Intens Care Unit, 899,Pinghai Rd,Gusu Dist, Suzhou 215000, Jiangsu, Peoples R China
关键词
fluid responsiveness; echocardiography; passive leg raising; gray zone; mechanical ventilation; PULSE PRESSURE VARIATION; METAANALYSIS;
D O I
10.1053/j.jvca.2023.02.009
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To assess whether velocity-time integral (VTI) variation and peak velocity (Vpeak) variation of the left ventricular outflow tract (LVOT) accurately could predict fluid responsiveness in postoperative critically ill patients mechanically ventilated at low tidal volumes.Design: A prospective, single-center, observational study.Setting: A surgical intensive care unit at a tertiary hospital.Participants: Sixty postoperative critically ill patients with deep sedation and mechanical ventilation (tidal volume <8 mL/kg) were included in this study.Interventions: Passive leg raising (PLR).Measurement and Main Results: Pulse pressure variation (PPV), VTI variation, and Vpeak variation were measured at baseline and after PLR by transthoracic echocardiography. The fluid responsiveness was defined as an increase (>10%) in stroke volume after PLR. Thirty-two (53.3%) patients were fluid responders. The areas under the receiver operating characteristic (AUROC) curves for PPV were 0.797, and the gray zone was large and included 58.3% of patients. Both VTI variation and Vpeak variation predicted fluid responsiveness with the AUROC of 0.919 and 0.905; meanwhile, the best cutoff values were 12.51% (sensitivity of 71.9%; specificity of 75.0%) and 11.76% (sensitivity of 81.3%; specificity of 89.3%). The gray zones of VTI variation and Vpeak variation were from 7.41% to 11.88% (contained 23.3% patients) and from 9.96% to 13.10% (contained 28.3% patients).Conclusions: In postoperative critically ill patients mechanically ventilated with tidal volume <8 mL/kg, the VTI variation and Vpeak variation of LVOT accurately could predict fluid responsiveness, and VTI variation showed more accuracy than Vpeak variation in predicting fluid responsiveness.(c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:911 / 918
页数:8
相关论文
共 32 条
  • [1] Predictors of fluid responsiveness in critically ill patients mechanically ventilated at low tidal volumes: systematic review and meta-analysis
    Alvarado Sanchez, Jorge Ivan
    Caicedo Ruiz, Juan Daniel
    Diaztagle Fernandez, Juan Jose
    Amaya Zuniga, William Fernando
    Ospina-Tascon, Gustavo Adolfo
    Cruz Martinez, Luis Eduardo
    [J]. ANNALS OF INTENSIVE CARE, 2021, 11 (01)
  • [2] Towards individualized perioperative, goal-directed haemodynamic algorithms for patients of advanced age: observations during a randomized controlled trial (NCT01141894)
    Bartha, E.
    Arfwedson, C.
    Imnell, A.
    Kalman, S.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2016, 116 (04) : 486 - 492
  • [3] Will This Hemodynamically Unstable Patient Respond to a Bolus of Intravenous Fluids?
    Bentzer, Peter
    Griesdale, Donald E.
    Boyd, John
    MacLean, Kelly
    Sirounis, Demetrios
    Ayas, Najib T.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (12): : 1298 - 1309
  • [4] Beurton A, 2019, CRIT CARE MED, V47, P639
  • [5] Clinical relevance of pulse pressure variations for predicting fluid responsiveness in mechanically ventilated intensive care unit patients: the grey zone approach
    Biais, Matthieu
    Ehrmann, Stephan
    Mari, Arnaud
    Conte, Benjamin
    Mahjoub, Yazine
    Desebbe, Olivier
    Pottecher, Julien
    Lakhal, Karim
    Benzekri-Lefevre, Dalila
    Molinari, Nicolas
    Boulain, Thierry
    Lefrant, Jean-Yves
    Muller, Laurent
    [J]. CRITICAL CARE, 2014, 18 (06):
  • [6] Fluid resuscitation in septic shock: A positive fluid balance and elevated central venous pressure are associated with increased mortality
    Boyd, John H.
    Forbes, Jason
    Nakada, Taka-aki
    Walley, Keith R.
    Russell, James A.
    [J]. CRITICAL CARE MEDICINE, 2011, 39 (02) : 259 - 265
  • [7] Fluid Management in Acute Respiratory Distress Syndrome
    Casey, Jonathan D.
    Semler, Matthew W.
    Rice, Todd W.
    [J]. SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 40 (01) : 57 - 65
  • [8] Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies
    Cavallaro, Fabio
    Sandroni, Claudio
    Marano, Cristina
    La Torre, Giuseppe
    Mannocci, Alice
    De Waure, Chiara
    Bello, Giuseppe
    Maviglia, Riccardo
    Antonelli, Massimo
    [J]. INTENSIVE CARE MEDICINE, 2010, 36 (09) : 1475 - 1483
  • [9] Predicting Fluid Responsiveness by Passive Leg Raising: A Systematic Review and Meta-Analysis of 23 Clinical Trials
    Cherpanath, Thomas G. V.
    Hirsch, Alexander
    Geerts, Bart F.
    Lagrand, Wim K.
    Leeflang, Mariska M.
    Schultz, Marcus J.
    Groeneveld, A. B. Johan
    [J]. CRITICAL CARE MEDICINE, 2016, 44 (05) : 981 - 991
  • [10] COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH
    DELONG, ER
    DELONG, DM
    CLARKEPEARSON, DI
    [J]. BIOMETRICS, 1988, 44 (03) : 837 - 845