Novel Apodized Fiber Bragg Grating Applied for Medical Sensors: Performance Investigation

被引:2
作者
Arumugam, Ramya [1 ]
Kumar, Ramamoorthy [1 ]
Dhanalakshmi, Samiappan [1 ]
Lai, Khin Wee [2 ]
Jiao, Lei [3 ]
Wu, Xiang [4 ]
机构
[1] SRM Inst Sci & Technol, Coll Engn & Technol, Dept Elect & Commun Engn, Chengalpattu 603203, India
[2] Univ Malaya, Fac Engn, Dept Biomed Engn, Kuala Lumpur 50603, Malaysia
[3] Xuzhou Min Grp, Gen Hosp, Xuzhou 221000, Peoples R China
[4] Xuzhou Med Univ, Sch Med Informat & Engn, Xuzhou 221000, Peoples R China
来源
CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES | 2023年 / 135卷 / 01期
关键词
Fiber bragg grating; apodization; optical sensing; temperature; strain; sensitivity; TEMPERATURE SENSOR; PHOTONIC CRYSTAL; FBG; SINGLE;
D O I
10.32604/cmes.2022.022144
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Sensors play an important role in shaping and monitoring human health. Exploration of methods to use Fiber Bragg Grating (FBG) with enhanced sensitivity has attracted great interest in the field of medical research. In this paper, a novel apodization function is proposed and performance evaluation and optimization of the same have been made. A comparison was conducted between various existing apodization functions and the proposed one based on optical characteristics and sensor parameters. The results evince the implementation of the proposed apodization function for vital sign measurement. The optical characteristics considered for evaluation are Peak Resonance Reflectivity level, Side Lobes Reflectivity level and Full Width Half Maximum (FWHM). The proposed novel apodization novel function has better FWHM, which is narrower than the FWHM of uniform FBG. Sensor characteristics like a quality parameter, detection accuracy and sensitivity also show improvement. The proposed novel apodization function is demonstrated to have a better shift in wavelength in terms of temperature and pulse measurement than the existing functions. The sensitivity of the proposed apodized function is enhanced with a Poly-dimethylsiloxane coating of varying thickness, which is 6 times and 5.14 times greater than uniform Fiber Bragg grating and FBG with the proposed novel apodization function, respectively, enhancing its utilization in the field of medicine.
引用
收藏
页码:301 / 323
页数:23
相关论文
共 49 条
  • [1] [Anonymous], 2012, 2012 S PHOT OPT SHAN, DOI [DOI 10.1109/VCIP.2012.6410775, DOI 10.1109/SOPO.2012.6271111]
  • [2] Arumugam Ramya, 2021, Proceedings of the International Conference on Optics and Electro-Optics ICOL-2019. Springer Proceedings in Physics (SPPHY 258), P271, DOI 10.1007/978-981-15-9259-1_62
  • [3] Arumugam R., 2022, KUALA LUMPUR INT C B, P341
  • [4] Ashik T, 2017, LET THERE BE LIGHT R, V1849
  • [5] Ashraf I., 2010, Proc. of ICC, P1
  • [6] Ashry Islam, 2010, 2010 17th International Conference on Telecommunications (ICT 2010), P534, DOI 10.1109/ICTEL.2010.5478865
  • [7] Ashry I., 2014, P 2014 ZONE 1 C AM S
  • [8] Fibre Bragg Grating Based Strain Sensors: Review of Technology and Applications
    Campanella, Carlo Edoardo
    Cuccovillo, Antonello
    Campanella, Clarissa
    Yurt, Abdulkadir
    Passaro, Vittorio M. N.
    [J]. SENSORS, 2018, 18 (09)
  • [9] Linear Temperature Distribution Sensor Using FBG in Liquids-Local Heat Transfer Examination Application
    Chakravartula, Venkatesh
    Rakshit, Sampita
    Dhanalakshmi, Samiappan
    Kumar, R.
    Narayanamoorthi, R.
    [J]. IEEE SENSORS JOURNAL, 2021, 21 (15) : 16651 - 16658
  • [10] Sensitivity enhancement analysis due to different coating materials of Fibre Bragg Grating-based depth sensor for underwater applications
    Chakravartula, Venkatesh
    Samiappan, Dhanalakshmi
    Kumar, R.