Ultra-low-dose CBCT scan: rational map for ear surgery

被引:4
作者
Tamminen, Pekka [1 ,2 ,3 ,6 ]
Jarnstedt, Jorma [4 ]
Lehtinen, Antti [4 ]
Numminen, Jura [1 ]
Lehtimaki, Lauri [5 ,6 ]
Rautiainen, Markus [1 ,6 ]
Kivekas, Ilkka [1 ]
机构
[1] Tampere Univ Hosp, Dept Otorhinolaryngol Head & Neck Surg, Elamanaukio 2, Tampere 33520, Finland
[2] Satasairaala, Dept Otorhinolaryngol, Sairaalantie 3, Pori 28500, Finland
[3] Tampere Univ Hosp, Dept Internal Med, Elamanaukio 2, Tampere 33520, Finland
[4] Tampere Univ Hosp, Med Imaging Ctr, Dept Radiol, Teiskontie 35, Tampere 33520, Finland
[5] Tampere Univ Hosp, Allergy Ctr, Elamanaukio 2, Tampere 33520, Finland
[6] Tampere Univ, Fac Med & Hlth Technol, Arvo Ylpon Katu 34, Tampere 33520, Finland
关键词
Cone beam computed tomography; Ultra-low-dose protocol; Temporal bone; Image quality; Ear surgery; BEAM COMPUTED-TOMOGRAPHY; ADULT; MULTISLICE; UTILITY;
D O I
10.1007/s00405-022-07592-4
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Purpose This study will evaluate the clinical quality and usability of peripheral image data from the temporal bone area obtained using a sinonasal ultra-low-dose (ULD) cone-beam computed tomography (CBCT) scan and compare them to those obtained using a high-resolution (HR) CBCT. Methods The population consisted of 66 anatomical sites (ears of 33 subjects) imaged using two modalities: an HR CBCT (Scanora 3Dx scanner; Soredex, Tuusula, Finland) and a ULD CBCT (Promax 3D Mid scanner; Plandent, Helsinki, Finland). The image quality (IQ) for every anatomical site in each image was rated using a Likert scale from 0 to 5. Results The quality of ULD CBCT scans was clinically sufficient in over 95% of the assessed images of the sigmoid sinus, jugular bulb, epitympanum and mastoid antrum as well as external acoustic meatus (all p > 0.05 compared to HR CBCT). The IQ was clinically sufficient in 75-94% of the assessed images of the scutum, mastoid segment of the facial nerve, cochlea and semicircular canals (all p < 0.05 compared to HR CBCT). The overall IQ of the HR CBCT scans was good or excellent. Conclusion CBCT imaging and the data at image margins are underutilized. CBCT can produce excellent structural resolution with conventional imaging parameters, even with off-focus images. Using ultra-low doses of radiation, the produced IQ is clinically sufficient. We encourage ear surgeons to check the patients' imaging history and to consider the use of imaging modalities that involve lower radiation doses especially when conducting repetitive investigations and with children.
引用
收藏
页码:1161 / 1168
页数:8
相关论文
共 21 条
  • [1] Basic principles for use of dental cone beam computed tomography: consensus guidelines of the European Academy of Dental and Maxillofacial Radiology
    Horner, K.
    Islam, M.
    Flygare, L.
    Tsiklakis, K.
    Whaites, E.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (04) : 187 - 195
  • [2] Cone-beam computed tomography: Time to move from ALARA to ALADA
    Jaju, Prashant P.
    Jaju, Sushma P.
    [J]. IMAGING SCIENCE IN DENTISTRY, 2015, 45 (04) : 263 - 265
  • [3] Jiang ZY, 2014, OTOL NEUROTOL, V35, P1533, DOI 10.1097/MAO.0000000000000453
  • [4] Cone-Beam CT Compared to Multi-Slice CT for the Diagnostic Analysis of Conductive Hearing Loss: A Feasibility Study
    Kemp, Pieter
    Van Stralen, Jiska
    De Graaf, Pim
    Berkhout, Erwin
    Van Horssen, Pepijn
    Merkus, Paul
    [J]. JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2020, 16 (02) : 222 - +
  • [5] ALADA Dose Optimization in the Computed Tomography of the Temporal Bone: The Diagnostic Potential of Different Low-Dose CT Protocols
    Kofler, Barbara
    Jenetten, Laura
    Runge, Annette
    Degenhart, Gerald
    Fischer, Natalie
    Hoermann, Romed
    Steurer, Michael
    Widmann, Gerlig
    [J]. DIAGNOSTICS, 2021, 11 (10)
  • [6] Radiation Risk From Medical Imaging
    Lin, Eugene C.
    [J]. MAYO CLINIC PROCEEDINGS, 2010, 85 (12) : 1142 - 1146
  • [7] Radiation dose in non-dental cone beam CT applications: a systematic review
    Nardi, Cosimo
    Salerno, Sergio
    Molteni, Roberto
    Occhipinti, Mariaelena
    Grazzini, Giulia
    Norberti, Niccolo
    Cordopatri, Cesare
    Colagrande, Stefano
    [J]. RADIOLOGIA MEDICA, 2018, 123 (10): : 765 - 777
  • [8] Technical aspects of dental CBCT: state of the art
    Pauwels, R.
    Araki, K.
    Siewerdsen, J. H.
    Thongvigitmanee, S. S.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (01)
  • [9] Pein MK, 2014, RADIOLOGE, V54, P271, DOI 10.1007/s00117-013-2644-9
  • [10] Limited cone-beam computed tomography imaging of the middle ear: A comparison with multislice helical computed tomography
    Peltonen, L. I.
    Aarnisalo, A. A.
    Kortesniemi, M. K.
    Suomalainen, A.
    Jero, J.
    Robinson, S.
    [J]. ACTA RADIOLOGICA, 2007, 48 (02) : 207 - 212