Biomechanically Compliant Gynecologic Training Simulator

被引:2
作者
Nadhif, Muhammad Hanif [1 ,2 ,5 ]
Irsyad, Muhammad
Ocviyanti, Dwiana [3 ,4 ,5 ]
机构
[1] Univ Indonesia, Ciptomangunkusumo Cent Hosp, Med Phys Dept, Jakarta, Indonesia
[2] Univ Indonesia, Ciptomangunkusumo Cent Hosp, Med Technol Cluster, Jakarta, Indonesia
[3] Univ Indonesia, Ciptomangunkusumo Cent Hosp, Indonesian Med Educ & Res Inst IMERI, Fac Med, Jakarta, Indonesia
[4] Univ Indonesia, Ciptomangunkusumo Cent Hosp, Fac Med, Dept Obstet & Gynecol, Jakarta, Indonesia
[5] Univ Indonesia, Fac Med, Jl Salemba Raya 6, Central Jakarta 10430, Indonesia
来源
SIMULATION IN HEALTHCARE-JOURNAL OF THE SOCIETY FOR SIMULATION IN HEALTHCARE | 2023年 / 18卷 / 02期
关键词
Biomechanically compliant; finite element analysis; healthcare simulation; gynecologic; silicone rubber; simulator; PROLAPSED VAGINAL TISSUE; FINITE-ELEMENT; MECHANICAL SIMULATOR; MODEL; PHANTOM; CERVIX;
D O I
10.1097/SIH.0000000000000654
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
IntroductionPap smear training is commonly conducted using simulators before practicing with humans. Unfortunately, existing simulators do not well simulate the biomechanical properties of pelvic tissues, and this may negatively impact the training outcome. In this study, we used finite element analysis (FEA) to identify a material that most accurately simulates pelvic tissues in terms of biomechanical properties for fabricating gynecologic training simulators. The selected material was then used to fabricate a vagina and cervix model using a hybrid technique of fused deposition modeling and molding to qualitatively confirm the structural integrity of the simulator.MethodsThe vagina and cervix were reconstructed in a 3-dimensional feature according to geometrical parameters reported in the literature. The biomechanical compliance of the simulators was investigated by comparing 5 materials-RTV615, Dragon Skin 10, Dragon Skin 30, Dragon Skin FX-Pro, and Ecoflex 00-30-and a pelvic tissue model (control) using 2 FEA modules. The structural mechanics module simulated the insertion and opening of a vaginal speculum, and the (1) horizontal opening of the vagina and peak von Mises stress at the anterior and (2) posterior walls of the vagina were obtained. The explicit dynamics module estimated (1) the fracture stress during punch biopsies and (2) maximum perpendicular deformation of the cervix before break. The most biomechanically compliant material was subsequently used to fabricate the simulator using the hybrid technique.ResultsFrom the FEA, the horizontal opening of the vagina, peak von Mises stress at the anterior wall of the vagina, peak von Mises stress at the posterior wall of the vagina fracture stress, and maximum perpendicular deformation of the cervix before break were obtained; the results of Dragon Skin 10 and the control were most similar. Therefore, the simulator was fabricated using the material. A qualitative evaluation of the simulator by the naked eye verified its structural integrity.ConclusionsOf the materials studied, the FEA results showed that Dragon Skin 10 was the most accurate material for simulating pelvic tissues in terms of the biomechanical properties in a gynecologic training simulator. The simulator was also successfully fabricated using the hybrid technique. Further studies may also involve experimental testing to support the simulation results.
引用
收藏
页码:135 / 143
页数:9
相关论文
共 50 条
[31]   Neuroendoscopic Training: Presentation of a New Real Simulator [J].
Zymberg, S. ;
Vaz-Guimaraes Filho, F. ;
Lyra, M. .
MINIMALLY INVASIVE NEUROSURGERY, 2010, 53 (01) :44-46
[32]   The role of cognitive abilities in laparoscopic simulator training [J].
M. Groenier ;
J. M. C. Schraagen ;
H. A. T. Miedema ;
I. A. J. M. Broeders .
Advances in Health Sciences Education, 2014, 19 :203-217
[33]   Virtual training simulator for atomic force microscopy [J].
Heying, Matthew J. ;
Oliver, James H. ;
Sundararajan, Sriram ;
Shrotriya, Pranav ;
Zou, Qingze .
Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference 2005, Vol 3, Pts A and B, 2005, :567-574
[34]   Implementation of instrument simulation on flight training simulator [J].
Zhang, LM ;
Teng, JF ;
Liu, FT .
PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 2, 2004, :626-631
[35]   A simulator for reinforcement learning training in the recommendation field [J].
Pang, Guangyao ;
Zhu, Xiaoying ;
Lu, Keda ;
Peng, Zizhen ;
Deng, Weitao .
2020 IEEE INTL SYMP ON PARALLEL & DISTRIBUTED PROCESSING WITH APPLICATIONS, INTL CONF ON BIG DATA & CLOUD COMPUTING, INTL SYMP SOCIAL COMPUTING & NETWORKING, INTL CONF ON SUSTAINABLE COMPUTING & COMMUNICATIONS (ISPA/BDCLOUD/SOCIALCOM/SUSTAINCOM 2020), 2020, :1037-1042
[36]   The Efficacy of a Newly Designed, Easy-to-Manufacture Training Simulator for Endoscopic Biopsy of the Stomach [J].
Ahn, Ji Yong ;
Lee, Jin Seo ;
Lee, Gin Hyug ;
Lee, Ji Wan ;
Na, Hee Kyong ;
Jung, Kee Wook ;
Lee, Jeong Hoon ;
Kim, Do Hoon ;
Choi, Kee Don ;
Song, Ho June ;
Jung, Hwoon-Yong ;
Kim, Jin-Ho .
GUT AND LIVER, 2016, 10 (05) :764-772
[37]   Development of a high fidelity pressurized porcine beating heart simulator for cardiac surgery training [J].
Ribeiro, Igo B. ;
Ngu, Janet M. C. ;
Gill, Gurinder ;
Rubens, Fraser D. .
PERFUSION-UK, 2017, 32 (07) :568-573
[38]   3D-printed pediatric endoscopic ear surgery simulator for surgical training [J].
Barber, Samuel R. ;
Kozin, Elliott D. ;
Dedmon, Matthew ;
Lin, Brian M. ;
Lee, Kyuwon ;
Sinha, Sumi ;
Black, Nicole ;
Remenschneider, Aaron K. ;
Lee, Daniel J. .
INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2016, 90 :113-118
[39]   Effectiveness of simulator training compared to machine training for equipment operators in the logging industry [J].
Burk, Erin ;
Han, Han-Sup ;
Smidt, Mathew ;
Fox, Bruce .
INTERNATIONAL JOURNAL OF FOREST ENGINEERING, 2023, 34 (03) :373-384
[40]   Surgical education and training in gynecologic oncology I: European perspective [J].
Cibula, David ;
Kesic, Vesna .
GYNECOLOGIC ONCOLOGY, 2009, 114 (02) :S52-S55