Biomechanically Compliant Gynecologic Training Simulator

被引:2
作者
Nadhif, Muhammad Hanif [1 ,2 ,5 ]
Irsyad, Muhammad
Ocviyanti, Dwiana [3 ,4 ,5 ]
机构
[1] Univ Indonesia, Ciptomangunkusumo Cent Hosp, Med Phys Dept, Jakarta, Indonesia
[2] Univ Indonesia, Ciptomangunkusumo Cent Hosp, Med Technol Cluster, Jakarta, Indonesia
[3] Univ Indonesia, Ciptomangunkusumo Cent Hosp, Indonesian Med Educ & Res Inst IMERI, Fac Med, Jakarta, Indonesia
[4] Univ Indonesia, Ciptomangunkusumo Cent Hosp, Fac Med, Dept Obstet & Gynecol, Jakarta, Indonesia
[5] Univ Indonesia, Fac Med, Jl Salemba Raya 6, Central Jakarta 10430, Indonesia
来源
SIMULATION IN HEALTHCARE-JOURNAL OF THE SOCIETY FOR SIMULATION IN HEALTHCARE | 2023年 / 18卷 / 02期
关键词
Biomechanically compliant; finite element analysis; healthcare simulation; gynecologic; silicone rubber; simulator; PROLAPSED VAGINAL TISSUE; FINITE-ELEMENT; MECHANICAL SIMULATOR; MODEL; PHANTOM; CERVIX;
D O I
10.1097/SIH.0000000000000654
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
IntroductionPap smear training is commonly conducted using simulators before practicing with humans. Unfortunately, existing simulators do not well simulate the biomechanical properties of pelvic tissues, and this may negatively impact the training outcome. In this study, we used finite element analysis (FEA) to identify a material that most accurately simulates pelvic tissues in terms of biomechanical properties for fabricating gynecologic training simulators. The selected material was then used to fabricate a vagina and cervix model using a hybrid technique of fused deposition modeling and molding to qualitatively confirm the structural integrity of the simulator.MethodsThe vagina and cervix were reconstructed in a 3-dimensional feature according to geometrical parameters reported in the literature. The biomechanical compliance of the simulators was investigated by comparing 5 materials-RTV615, Dragon Skin 10, Dragon Skin 30, Dragon Skin FX-Pro, and Ecoflex 00-30-and a pelvic tissue model (control) using 2 FEA modules. The structural mechanics module simulated the insertion and opening of a vaginal speculum, and the (1) horizontal opening of the vagina and peak von Mises stress at the anterior and (2) posterior walls of the vagina were obtained. The explicit dynamics module estimated (1) the fracture stress during punch biopsies and (2) maximum perpendicular deformation of the cervix before break. The most biomechanically compliant material was subsequently used to fabricate the simulator using the hybrid technique.ResultsFrom the FEA, the horizontal opening of the vagina, peak von Mises stress at the anterior wall of the vagina, peak von Mises stress at the posterior wall of the vagina fracture stress, and maximum perpendicular deformation of the cervix before break were obtained; the results of Dragon Skin 10 and the control were most similar. Therefore, the simulator was fabricated using the material. A qualitative evaluation of the simulator by the naked eye verified its structural integrity.ConclusionsOf the materials studied, the FEA results showed that Dragon Skin 10 was the most accurate material for simulating pelvic tissues in terms of the biomechanical properties in a gynecologic training simulator. The simulator was also successfully fabricated using the hybrid technique. Further studies may also involve experimental testing to support the simulation results.
引用
收藏
页码:135 / 143
页数:9
相关论文
共 50 条
  • [21] Design of Ship Light Communication Training Simulator
    Zhang Xu
    Liu Hongbo
    Qu Shanhu
    2019 CROSS STRAIT QUAD-REGIONAL RADIO SCIENCE AND WIRELESS TECHNOLOGY CONFERENCE (CSQRWC), 2019,
  • [22] Simulator for training operators in hydroelectric minipower stations
    Macarulla-Arenaza, AM
    García-Quintanilla, JI
    López-Guntiñas, JL
    Pinacho-Alonso, E
    Proceedings of the IASTED International Conference on Applied Simulation and Modelling, 2004, : 41 - 46
  • [23] Simulator Training Optimization of UAV External Pilots
    Shmelev, Juriy
    2014 IEEE 3RD INTERNATIONAL CONFERENCE ON METHODS AND SYSTEMS OF NAVIGATION AND MOTION CONTROL (MSNMC), 2014, : 75 - 78
  • [24] A cardiovascular simulator tailored for training and clinical uses
    Fresiello, L.
    Ferrari, G.
    Di Molfetta, A.
    Zielinski, K.
    Tzallas, A.
    Jacobs, S.
    Darowski, M.
    Kozarski, M.
    Meyns, B.
    Katertsidis, N. S.
    Karvounis, E. C.
    Tsipouras, M. G.
    Trivella, M. G.
    JOURNAL OF BIOMEDICAL INFORMATICS, 2015, 57 : 100 - 112
  • [25] The role of cognitive abilities in laparoscopic simulator training
    Groenier, M.
    Schraagen, J. M. C.
    Miedema, H. A. T.
    Broeders, I. A. J. M.
    ADVANCES IN HEALTH SCIENCES EDUCATION, 2014, 19 (02) : 203 - 217
  • [26] Low Cost Simulator for Heart Surgery Training
    Rocha e Silva, Roberto
    Lourencao, Artur, Jr.
    Goncharov, Maxim
    Jatene, Fabio B.
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2016, 31 (06) : 449 - 453
  • [27] Computer simulator for training operators of infrared camera
    Sugisaka, M.
    Faizal Abdullah, Erma Rahayu Binti Mohd.
    2006 SICE-ICASE INTERNATIONAL JOINT CONFERENCE, VOLS 1-13, 2006, : 3425 - +
  • [28] Simulator-Based Training of Workflow in Echocardiography
    Mahboobi, Sohail
    Mahmood, Faraz
    Bortman, Jeffrey
    Chaudhry, Daawar
    Shui, Helen
    Baribeau, Yanick
    Feng, Ruby
    Mahmood, Feroze
    Matyal, Robina
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (06) : 1533 - 1539
  • [29] Operator Training Simulator for an Industrial Bioethanol Plant
    Gerlach, Inga
    Tholin, Soren
    Hass, Volker C.
    Mandenius, Carl-Fredrik
    PROCESSES, 2016, 4 (04):
  • [30] Evidence of the benefit of simulator training for the education of surgeons
    Phillips, Melissa S.
    Ponsky, Jeffrey L.
    TECHNIQUES IN GASTROINTESTINAL ENDOSCOPY, 2011, 13 (02) : 119 - 125