Biomechanically Compliant Gynecologic Training Simulator

被引:2
作者
Nadhif, Muhammad Hanif [1 ,2 ,5 ]
Irsyad, Muhammad
Ocviyanti, Dwiana [3 ,4 ,5 ]
机构
[1] Univ Indonesia, Ciptomangunkusumo Cent Hosp, Med Phys Dept, Jakarta, Indonesia
[2] Univ Indonesia, Ciptomangunkusumo Cent Hosp, Med Technol Cluster, Jakarta, Indonesia
[3] Univ Indonesia, Ciptomangunkusumo Cent Hosp, Indonesian Med Educ & Res Inst IMERI, Fac Med, Jakarta, Indonesia
[4] Univ Indonesia, Ciptomangunkusumo Cent Hosp, Fac Med, Dept Obstet & Gynecol, Jakarta, Indonesia
[5] Univ Indonesia, Fac Med, Jl Salemba Raya 6, Central Jakarta 10430, Indonesia
来源
SIMULATION IN HEALTHCARE-JOURNAL OF THE SOCIETY FOR SIMULATION IN HEALTHCARE | 2023年 / 18卷 / 02期
关键词
Biomechanically compliant; finite element analysis; healthcare simulation; gynecologic; silicone rubber; simulator; PROLAPSED VAGINAL TISSUE; FINITE-ELEMENT; MECHANICAL SIMULATOR; MODEL; PHANTOM; CERVIX;
D O I
10.1097/SIH.0000000000000654
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
IntroductionPap smear training is commonly conducted using simulators before practicing with humans. Unfortunately, existing simulators do not well simulate the biomechanical properties of pelvic tissues, and this may negatively impact the training outcome. In this study, we used finite element analysis (FEA) to identify a material that most accurately simulates pelvic tissues in terms of biomechanical properties for fabricating gynecologic training simulators. The selected material was then used to fabricate a vagina and cervix model using a hybrid technique of fused deposition modeling and molding to qualitatively confirm the structural integrity of the simulator.MethodsThe vagina and cervix were reconstructed in a 3-dimensional feature according to geometrical parameters reported in the literature. The biomechanical compliance of the simulators was investigated by comparing 5 materials-RTV615, Dragon Skin 10, Dragon Skin 30, Dragon Skin FX-Pro, and Ecoflex 00-30-and a pelvic tissue model (control) using 2 FEA modules. The structural mechanics module simulated the insertion and opening of a vaginal speculum, and the (1) horizontal opening of the vagina and peak von Mises stress at the anterior and (2) posterior walls of the vagina were obtained. The explicit dynamics module estimated (1) the fracture stress during punch biopsies and (2) maximum perpendicular deformation of the cervix before break. The most biomechanically compliant material was subsequently used to fabricate the simulator using the hybrid technique.ResultsFrom the FEA, the horizontal opening of the vagina, peak von Mises stress at the anterior wall of the vagina, peak von Mises stress at the posterior wall of the vagina fracture stress, and maximum perpendicular deformation of the cervix before break were obtained; the results of Dragon Skin 10 and the control were most similar. Therefore, the simulator was fabricated using the material. A qualitative evaluation of the simulator by the naked eye verified its structural integrity.ConclusionsOf the materials studied, the FEA results showed that Dragon Skin 10 was the most accurate material for simulating pelvic tissues in terms of the biomechanical properties in a gynecologic training simulator. The simulator was also successfully fabricated using the hybrid technique. Further studies may also involve experimental testing to support the simulation results.
引用
收藏
页码:135 / 143
页数:9
相关论文
共 51 条
[1]   The Role of 3D-Printed Phantoms and Devices for Organ-specified Appliances in Urology [J].
Agung, Natanael Parningotan ;
Nadhif, Muhammad Hanif ;
Irdam, Gampo Alam ;
Mochtar, Chaidir Arif .
INTERNATIONAL JOURNAL OF BIOPRINTING, 2021, 7 (02) :1-14
[2]   National screening programs for cervical cancer in Asian countries [J].
Aoki, Eiko Saitoh ;
Yin, Rutie ;
Li, Kemin ;
Bhatla, Neerja ;
Singhal, Seema ;
Ocviyanti, Dwiana ;
Saika, Kumiko ;
Suh, Mina ;
Kim, Miseon ;
Termrungruanglert, Wichai .
JOURNAL OF GYNECOLOGIC ONCOLOGY, 2020, 31 (03)
[3]   Use of a mechanical simulator for training in applying cricoid pressure [J].
Ashurst, N ;
Rout, CC ;
Rocke, BA ;
Gouws, E .
BRITISH JOURNAL OF ANAESTHESIA, 1996, 77 (04) :468-472
[4]   Design and preliminary analysis of a vaginal inserter for speculum-free cervical cancer screening [J].
Asiedu, Mercy Nyamewaa ;
Agudogo, Julia ;
Krieger, Marlee S. ;
Miros, Robert ;
Proeschold-Bell, Rae Jean ;
Schmitt, John W. ;
Ramanujam, Nimmi .
PLOS ONE, 2017, 12 (05)
[5]  
BARBIERI RL, 1992, FERTIL STERIL, V57, P727
[6]   Baseline dimensions of the human vagina [J].
Barnhart, Kurt T. ;
Izquierdo, Adriana ;
Pretorius, E. Scott ;
Shera, David M. ;
Shabbout, Mayadah ;
Shaunik, Alka .
HUMAN REPRODUCTION, 2006, 21 (06) :1618-1622
[7]  
Bootsma K., 2016, MAT USED TISSUE PHAN, DOI [10.1007/8415_2016_1, DOI 10.1007/8415_2016_1]
[8]   The Next Generation of Endoscopic Simulation [J].
Cohen, Jonathan ;
Thompson, Christopher C. .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2013, 108 (07) :1036-1039
[9]   Translation of biomechanics research to urogynecology [J].
da Silva-Filho, Agnaldo Lopes ;
Martins, Pedro A. L. S. ;
Parente, Marco P. ;
Saleme, Cristina S. ;
Roza, Thuane ;
Pinotti, Marcos ;
Mascarenhas, Teresa ;
Natal Jorge, Renato M. .
ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2010, 282 (02) :149-155
[10]   Simulation in obstetrics and gynecology [J].
Gardner, Roxane ;
Raemer, Daniel B. .
OBSTETRICS AND GYNECOLOGY CLINICS OF NORTH AMERICA, 2008, 35 (01) :97-+