Stationary and mobile storages-based renewable off-grid system planning considering storage degradation cost based on information-gap decision theory optimization

被引:87
作者
Jokar, Mohammad Reza [1 ]
Shahmoradi, Saeid [2 ]
Mohammed, Adil Hussein [3 ]
Foong, Loke Kok [4 ,5 ]
Le, Binh Nguyen [4 ,5 ]
Pirouzi, Sasan [6 ]
机构
[1] Univ shahed, Fac Elect & Comp Engn, Tehran, Iran
[2] Khuzestan Water & Power Author, Ahvaz, Iran
[3] Cihan Univ Erbil, Fac Engn, Dept Commun & Comp Engn, Erbil, Kurdistan Regio, Iraq
[4] Duy Tan Univ, Inst Res & Dev, Da Nang, Vietnam
[5] Duy Tan Univ, Sch Engn & Technol, Da Nang, Vietnam
[6] Islamic Azad Univ, Dept Engn, Semirom Branch, Semirom, Iran
关键词
Bio-waste energy unit; Hybrid solution algorithm; Information -gap decision theory; Off -grid system; Stationary and mobile storage; Storage degradation cost; PERFORMANCE ANALYSIS; OPTIMAL-DESIGN; ALGORITHM; STRATEGIES; COVERAGE;
D O I
10.1016/j.est.2022.106389
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents the planning of a hybrid renewable system with wind turbines and bio-waste energy units along with stationary (i.e., batteries) and mobile (i.e., electric vehicles) energy storage. This model minimizes the cost of construction, maintenance and storage degradation. In this model, the energy supply priority is given to renewable sources. Then the mentioned storage devices are used to cover the gap between the load profile and the renewable generation power. The proposed scheme addresses the uncertainties of loads, renewable power and energy consumption of mobile storage devices. Therefore, robust optimization based on information-gap decision theory (IGDT) is utilized to obtain a robust solution against the prediction error of the aforemen-tioned uncertainties. Also, the hybrid optimization algorithm of honey bee mating and artificial bee colony is derived, showing the optimal solution with low dispersion in the final response. The proposed design is applied to the data of the city of Espoo, Finland. The obtained numerical results show the capability of the proposed design in deriving robust economic planning for the proposed hybrid system. So, the used hybrid solution al-gorithm is able to obtain the best solution in a lower computation time compared to non-hybrid solvers, and it has a low standard deviation around 0.94 % in the final response. The presence of the aforementioned renewable sources leads to attaining an environment-friendly hybrid system. The optimal performance of the storage de-vices leads to the robustness of the optimal solution against the maximum error of 18.19 % in the prediction of uncertainties. This occurs considering the smart charging management of mobile storage, but the maximum uncertainty level of 11.12 % holds to non-smart management of these storage devices in the proposed scheme. The energy management of mobile storage devices based on smart (non-smart) charging strategy also reduces (increases) the planning cost of the off-grid system by 7.62 % (39.68 %) compared to their absence.
引用
收藏
页数:15
相关论文
共 55 条
[1]   IGDT-Based Robust Optimization for Multicarrier Energy System Management [J].
Afrashi, K. ;
Bahmani-Firouzi, B. ;
Nafar, M. .
IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF ELECTRICAL ENGINEERING, 2021, 45 (01) :155-169
[2]   Honey-bee mating optimization (HBMO) algorithm for optimal reservoir operation [J].
Afshar, A. ;
Bozorg-Haddad, Omid ;
Marino, M. A. ;
Adams, B. J. .
JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2007, 344 (05) :452-462
[3]   Hydrogen production via using excess electric energy of an off-grid hybrid solar/wind system based on a novel performance indicator [J].
Al-Buraiki, Abdulrahman S. ;
Al-Sharafi, Abdullah .
ENERGY CONVERSION AND MANAGEMENT, 2022, 254
[4]  
[Anonymous], 2013, Vehicle-to-grid Reactive Power Operation Analysis of the EV/ PHEV Bidirectional Battery Charger
[5]   Renewable Generation and Transmission Expansion Planning Coordination with Energy Storage System: A Flexibility Point of View [J].
Ansari, Mohammad Reza ;
Pirouzi, Sasan ;
Kazemi, Mostafa ;
Naderipour, Amirreza ;
Benbouzid, Mohamed .
APPLIED SCIENCES-BASEL, 2021, 11 (08)
[6]   Designing an optimized configuration for a hybrid PV/Diesel/Battery Energy System based on metaheuristics: A case study on Gobi Desert [J].
Ashraf, Muhammad Aqeel ;
Liu, Zhenling ;
Alizadeh, As'ad ;
Nojavan, Sayyad ;
Jermsittiparsert, Kittisak ;
Zhang, Dangquan .
JOURNAL OF CLEANER PRODUCTION, 2020, 270
[7]   Optimizing an off-grid electrical system in Brochet, Manitoba, Canada [J].
Bhattarai, Prasid Ram ;
Thompson, Shirley .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 53 :709-719
[8]   Two-stage hybrid stochastic/robust optimal coordination of distributed battery storage planning and flexible energy management in smart distribution network [J].
Bozorgavari, Seyed Aboozar ;
Aghaei, Jamshid ;
Pirouzi, Sasan ;
Vahidinasab, Vahid ;
Farahmand, Hossein ;
Korpas, Magnus .
JOURNAL OF ENERGY STORAGE, 2019, 26
[9]   Design, dynamic simulation, and optimal size selection of a hybrid solar/wind and battery-based system for off-grid energy supply [J].
Cao, Yan ;
Taslimi, Melika S. ;
Dastjerdi, Sajad Maleki ;
Ahmadi, Pouria ;
Ashjaee, Mehdi .
RENEWABLE ENERGY, 2022, 187 :1082-1099
[10]   Addressing Technology Uncertainties in Battery Energy Storage Sizing Procedures [J].
Carpinelli G. ;
Mottola F. ;
Proto D. .
International Journal of Emerging Electric Power Systems, 2017, 18 (02)