Energy spectrum measurement of scattered X-rays during IVR procedure

被引:0
|
作者
Oikawa, Joma [1 ,2 ]
Sakai, Jun [2 ]
Fujiwara, Yusuke [3 ]
Tsurusawa, Kota [4 ]
Shimao, Daisuke [5 ]
Date, Hiroyuki [6 ]
Sugimori, Hiroyuki [6 ]
机构
[1] Hokkaido Univ, Grad Sch Hlth Sci, N12 W5,Kita Ku, Sapporo 0600812, Japan
[2] Sapporo Shuyukai Hosp, Dept Radiol, 6-2-1,Shinhassamu 5 Jo,Teine Ku, Sapporo 0060805, Japan
[3] Sapporo Shuyukai Hosp, Dept Neurosurg, 6-2-1, Shinhassamu 5 Jo,Teine Ku, Sapporo 0060805, Japan
[4] Sapporo Higashi Tokushukai Hosp, Dept Radiol, N33 E14,Higashi Ku, Sapporo 0650033, Japan
[5] Hokkaido Univ Sci, Fac Hlth Sci, Dept Radiol Technol, 15-4-1,Maeda 7 Jo,Teine Ku, Sapporo 0068585, Japan
[6] Hokkaido Univ, Fac Hlth Sci, N12 W5,Kita Ku, Sapporo 0600812, Japan
关键词
DEPENDENCE;
D O I
10.1093/rpd/ncad290
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
With the increase of the number of interventional radiology (IVR) procedures, the occupational exposure of operators and medical staff has attracted keen attention. The energy of scattered radiation in medical clinical sites is important for estimating the biological effects of occupational exposure. Recent years have seen many reports on the dose of scattered radiation by IVR, but few on the energy spectrum. In this study, the energy spectrum of scattered X-rays was measured by using a cadmium telluride (CdTe) semiconductor detector during IVR on several neurosurgical and cardiovascular cases. The cumulated spectra in each case were compared. The spectra showed little changes among neurosurgical cases and relatively large changes among cardiovascular cases. This was assumed to be due to the change of X-ray tube voltage and tube angle was larger in cardiovascular cases. The resulting energy spectra will be essential for the assessment of detailed biological effects of occupational exposure.
引用
收藏
页码:181 / 186
页数:6
相关论文
共 50 条
  • [22] Energy Spectrum Inference of X-Rays From a Linac
    Kotoku, J.
    Kobayashi, T.
    Arai, N.
    Hatakeyama, T.
    Kumagai, S.
    Haga, A.
    MEDICAL PHYSICS, 2012, 39 (06) : 3715 - 3715
  • [23] THE SPECTRUM AND ANGULAR-DISTRIBUTION OF X-RAYS SCATTERED FROM A WATER PHANTOM
    CHENG, CW
    TAYLOR, KW
    HOLLOWAY, AF
    MEDICAL PHYSICS, 1995, 22 (08) : 1235 - 1245
  • [24] Scattered x-rays in x-ray photography
    Wilsey, RB
    JOURNAL OF THE FRANKLIN INSTITUTE, 1922, 194 : 583 - 596
  • [25] MEASUREMENT OF THE SPECTRAL DISTRIBUTION OF SCATTERED 400 KVP X-RAYS IN A WATER PHANTOM
    CORMACK, DV
    GRIFFITH, TJ
    JOHNS, HE
    BRITISH JOURNAL OF RADIOLOGY, 1957, 30 (351): : 129 - 135
  • [26] POLARIZATION OF X-RAYS SCATTERED INTO 90 degree .
    Hanson, A.L.
    Nuclear instruments and methods in physics research, 1986, A249 (2-3): : 515 - 521
  • [27] METHOD OF CALIBRATING DOSIMETERS IN SCATTERED X-RAYS
    GLEZIN, FI
    KLEIMENOVA, LV
    SKOMOROKHOVA, TI
    FROLOVA, AV
    SHIRMER, EV
    MEASUREMENT TECHNIQUES USSR, 1982, 25 (10): : 842 - 843
  • [28] Energy spectra measurement of fluorescence X-rays radiation
    Guo Siming
    Wu Jinjie
    Zhang Jian
    Li Mengshi
    Hou Dongjie
    Wang Ji
    Thai Yudan
    PROCEEDINGS OF 2019 14TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), 2019, : 1375 - 1381
  • [29] Recoil of electrons from scattered X-rays
    Wilson, CTR
    NATURE, 1923, 112 : 435 - 435
  • [30] A double crystal study of scattered x-rays
    Bearden, JA
    PHYSICAL REVIEW, 1930, 36 (05): : 0791 - 0798