Research status of glued-in rods connections in wood structures

被引:12
作者
Zhang, Han [1 ,2 ]
Li, Haitao [1 ,2 ]
Dauletbek, Assima [1 ,2 ]
Lorenzo, Rodolfo [3 ]
Corbi, Ileana [4 ]
Corbi, Ottavia [4 ]
机构
[1] Nanjing Forestry Univ, Coll Civil Engn, Nanjing 210037, Peoples R China
[2] Nanjing Forestry Univ, Joint Int Res Lab Biocomposite Bldg Mat & Struct, Nanjing 210037, Peoples R China
[3] UCL, London WC1E 6BT, England
[4] Univ Naples Federico II, Via Claudio 21, I-80133 Naples, Italy
来源
JOURNAL OF BUILDING ENGINEERING | 2023年 / 65卷
基金
中国国家自然科学基金;
关键词
Wood structure; Glued-in rod; Influence factor; Design suggestion; PULL-OUT STRENGTH; THREADED STEEL RODS; BASALT FRP RODS; TIMBER JOINTS; GLULAM PARALLEL; GFRP RODS; BEHAVIOR; MOMENT; SINGLE; GRAIN;
D O I
10.1016/j.jobe.2022.105782
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Glued-in rods connections are widely used as a post-anchoring reinforcement technique in timber structures. The rods are inserted into boreholes with adhesive and then cured to form a whole with high strength, stiffness, and aesthetic properties. Although the glued-in-bar connections have been applied successfully, there are still some problems in the research of these connections in wood structures. There is still no unified standard for glued-in connections in wood structures. In this paper, the state of the art in glued-in-rod connections in wood structures is presented, the main influencing factors, failure modes glued-in rod, and the design methods of glued-in rod con-nections are summarized. The study provides a reference to bonded bar connections and the de-velopment of recommended design methods glued-in rod.
引用
收藏
页数:20
相关论文
共 130 条
  • [61] Law P. W., 1989, Proceedings of the second Pacific Timber Engineering Conference, University of Auckland, New Zealand, 28-31 August 1989. Volume 3., P85
  • [62] Review on research progress of metal-plate-connected wood joints
    Ling, Tingting
    Mohrmann, Sarah
    Li, Haitao
    Bao, Ningzhong
    Gaff, Milan
    Lorenzo, Rodolfo
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 59
  • [63] Ling Z.B., 2015, BOND ANCHORAGE SEISM
  • [64] Pull-out strength and bond behaviour of axially loaded rebar glued-in glulam
    Ling, Zhibin
    Yang, Huifeng
    Liu, Weiqing
    Lu, Weidong
    Zhou, Ding
    Wang, Lu
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2014, 65 : 440 - 449
  • [65] [凌志彬 Ling Zhibin], 2013, [建筑结构学报, Journal of Building Structures], V34, P132
  • [66] Liu Y.Y., 2022, SUSTAIN STRUCT, V2, DOI [10.54113/j.sust.2022.000017, DOI 10.54113/J.SUST.2022.000017]
  • [67] 少林寺初祖庵大殿铺作模型拟静力试验
    刘义凡
    侯同宇
    滕启城
    吕红医
    李哲瑞
    阙泽利
    [J]. 林业工程学报, 2021, (05) : 46 - 53
  • [68] Factors affecting the bond between polymer composites and wood
    Lyons, JS
    Ahmed, MR
    [J]. JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2005, 24 (04) : 405 - 412
  • [69] Behaviour of timber connections using glued-in GFRP rods under fatigue loading. Part II: Moment-resisting connections
    Madhoushi, Mehrab
    Ansell, Martin P.
    [J]. COMPOSITES PART B-ENGINEERING, 2008, 39 (02) : 249 - 257
  • [70] Behaviour of timber connections using glued-in GFRP rods under fatigue loading. Part 1: In-line beam to beam connections
    Madhoushi, Mehrab
    Ansell, Martin P.
    [J]. COMPOSITES PART B-ENGINEERING, 2008, 39 (02) : 243 - 248