Big-data and artificial-intelligence-assisted vault prediction and EVO-ICL size selection for myopia correction

被引:50
作者
Shen, Yang [1 ,2 ,3 ]
Wang, Lin [4 ,5 ]
Jian, Weijun [1 ,2 ,3 ]
Shang, Jianmin [1 ,2 ,3 ]
Wang, Xin [4 ]
Ju, Lie [4 ,5 ]
Li, Meiyan [1 ,2 ,3 ]
Zhao, Jing [1 ,2 ,3 ]
Chen, Xun [1 ,2 ,3 ]
Ge, Zongyuan [4 ,5 ]
Wang, Xiaoying [1 ,2 ,3 ]
Zhou, Xingtao [1 ,2 ,3 ]
机构
[1] Fudan Univ, Dept Ophthalmol & Optometry, Eye Ear Nose & Throat Hosp, Shanghai, Peoples R China
[2] NHC Key Lab Myopia, Shanghai, Peoples R China
[3] Shanghai Res Ctr Ophthalmol & Optometry, Shanghai, Peoples R China
[4] Beijing Airdoc Technol Co Ltd, Beijing, Peoples R China
[5] Monash Univ, Clayton, Vic, Australia
基金
中国国家自然科学基金;
关键词
treatment surgery; WHITE-TO-WHITE; COLLAMER; IMPLANTATION;
D O I
10.1136/bjophthalmol-2021-319618
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims To predict the vault and the EVO-implantable collamer lens (ICL) size by artificial intelligence (AI) and big data analytics. Methods Six thousand two hundred and ninety-seven eyes implanted with an ICL from 3536 patients were included. The vault values were measured by the anterior segment analyzer (Pentacam HR). Permutation importance and Impurity-based feature importance are used to investigate the importance between the vault and input parameters. Regression models and classification models are applied to predict the vault. The ICL size is set as the target of the prediction, and the vault and the other input features are set as the new inputs for the ICL size prediction. Data were collected from 2015 to 2020. Random Forest, Gradient Boosting and XGBoost were demonstrated satisfying accuracy and mean area under the curve (AUC) scores in vault predicting and ICL sizing. Results In the prediction of the vault, the Random Forest has the best results in the regression model (R-2=0.315), then follows the Gradient Boosting (R-2=0.291) and XGBoost (R-2=0.285). The maximum classification accuracy is 0.828 in Random Forest, and the mean AUC is 0.765. The Random Forest predicts the ICL size with an accuracy of 82.2% and the Gradient Boosting and XGBoost, which are also compatible with 81.5% and 81.8% accuracy, respectively. Conclusions Random Forest, Gradient Boosting and XGBoost models are applicable for vault predicting and ICL sizing. AI may assist ophthalmologists in improving ICL surgery safety, designing surgical strategies, and predicting clinical outcomes.
引用
收藏
页码:201 / 206
页数:6
相关论文
共 28 条
[1]   Improved Automated Detection of Diabetic Retinopathy on a Publicly Available Dataset Through Integration of Deep Learning [J].
Abramoff, Michael David ;
Lou, Yiyue ;
Erginay, Ali ;
Clarida, Warren ;
Amelon, Ryan ;
Folk, James C. ;
Niemeijer, Meindert .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (13) :5200-5206
[2]   Central vault after phakic intraocular lens implantation: Correlation with anterior chamber depth, white-to-white distance, spherical equivalent, and patient age [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Lisa, Carlos ;
Fernandes, Paulo ;
Jorge, Jorge ;
Montes Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (01) :46-53
[3]   Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation [J].
Alfonso, Jose F. ;
Lisa, Carlos ;
Palacios, Ana ;
Fernandes, Paulo ;
Gonzalez-Meijome, Jose M. ;
Montes-Mico, Robert .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (06) :978-983
[4]   Random forests [J].
Breiman, L .
MACHINE LEARNING, 2001, 45 (01) :5-32
[5]   XGBoost: A Scalable Tree Boosting System [J].
Chen, Tianqi ;
Guestrin, Carlos .
KDD'16: PROCEEDINGS OF THE 22ND ACM SIGKDD INTERNATIONAL CONFERENCE ON KNOWLEDGE DISCOVERY AND DATA MINING, 2016, :785-794
[6]   Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c) [J].
Chen, Xun ;
Miao, Huamao ;
Naidu, Rajeev Krishnan ;
Wang, Xiaoying ;
Zhou, Xingtao .
BMC OPHTHALMOLOGY, 2016, 16
[7]   Ten-year clinical outcomes after implantation of a posterior chamber phakic intraocular lens for myopia [J].
Choi, Jae Hwan ;
Lim, Dong Hui ;
Nam, Seung Wan ;
Yang, Chan Min ;
Chung, Eui Sang ;
Chung, Tae-Young .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (11) :1555-1561
[8]   Investigation of the causes of non-tolerance to optometric prescriptions for spectacles [J].
Freeman, Catherine E. ;
Evans, Bruce J. W. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2010, 30 (01) :1-11
[9]   Random forest as a generic framework for predictive modeling of spatial and spatio-temporal variables [J].
Hengl, Tomislav ;
Nussbaum, Madlene ;
Wright, Marvin N. ;
Heuvelink, Gerard B. M. ;
Graeler, Benedikt .
PEERJ, 2018, 6
[10]   Quality of Life in High Myopia before and after Implantable Collamer Lens Implantation [J].
Ieong, Alvin ;
Hau, Scott C. H. ;
Rubin, Gary S. ;
Allan, Bruce D. S. .
OPHTHALMOLOGY, 2010, 117 (12) :2295-2300