Incorporating variable RBE in IMPT optimization for ependymoma

被引:3
|
作者
Goudarzi, Hadis Moazami [1 ]
Lim, Gino [1 ]
Grosshans, David [2 ]
Mohan, Radhe [3 ]
Cao, Wenhua [3 ]
机构
[1] Univ Houston, Dept Ind Engn, Houston, TX USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, 1515 Holcombe Blvd, Houston, TX 77578 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2024年 / 25卷 / 01期
基金
美国国家卫生研究院;
关键词
ependymoma; IMPT; LET; optimization; RBE; RELATIVE BIOLOGICAL EFFECTIVENESS; LINEAR-ENERGY-TRANSFER; MODULATED PROTON THERAPY; BRAIN NECROSIS; MODEL; RADIOTHERAPY; VALUES; ORGANS; POINT;
D O I
10.1002/acm2.14207
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo study the dosimetric impact of incorporating variable relative biological effectiveness (RBE) of protons in optimizing intensity-modulated proton therapy (IMPT) treatment plans and to compare it with conventional constant RBE optimization and linear energy transfer (LET)-based optimization.MethodsThis study included 10 pediatric ependymoma patients with challenging anatomical features for treatment planning. Four plans were generated for each patient according to different optimization strategies: (1) constant RBE optimization (ConstRBEopt) considering standard-of-care dose requirements; (2) LET optimization (LETopt) using a composite cost function simultaneously optimizing dose-averaged LET (LETd) and dose; (3) variable RBE optimization (VarRBEopt) using a recent phenomenological RBE model developed by McNamara et al.; and (4) hybrid RBE optimization (hRBEopt) assuming constant RBE for the target and variable RBE for organs at risk. By normalizing each plan to obtain the same target coverage in either constant or variable RBE, we compared dose, LETd, LET-weighted dose, and equivalent uniform dose between the different optimization approaches.ResultsWe found that the LETopt plans consistently achieved increased LET in tumor targets and similar or decreased LET in critical organs compared to other plans. On average, the VarRBEopt plans achieved lower mean and maximum doses with both constant and variable RBE in the brainstem and spinal cord for all 10 patients. To compensate for the underdosing of targets with 1.1 RBE for the VarRBEopt plans, the hRBEopt plans achieved higher physical dose in targets and reduced mean and especially maximum variable RBE doses compared to the ConstRBEopt and LETopt plans.ConclusionWe demonstrated the feasibility of directly incorporating variable RBE models in IMPT optimization. A hybrid RBE optimization strategy showed potential for clinical implementation by maintaining all current dose limits and reducing the incidence of high RBE in critical normal tissues in ependymoma patients.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Impact of variable RBE on proton fractionation
    Dasu, Alexandru
    Toma-Dasu, Iuliana
    MEDICAL PHYSICS, 2013, 40 (01)
  • [2] PTV-based IMPT optimization incorporating planning risk volumes vs robust optimization
    Liu, Wei
    Frank, Steven J.
    Li, Xiaoqiang
    Li, Yupeng
    Zhu, Ron. X.
    Mohan, Radhe
    MEDICAL PHYSICS, 2013, 40 (02)
  • [3] Quantification of the uncertainties of a biological model and their impact on variable RBE proton treatment plan optimization
    Resch, A. F.
    Landry, G.
    Kamp, F.
    Cabal, G.
    Belka, C.
    Wilkens, J. J.
    Parodi, K.
    Dedes, G.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 36 : 91 - 102
  • [4] Robust optimization incorporating weekly predicted anatomical CTs in IMPT of nasopharyngeal cancer
    Chan, Mark Ka Heng
    Zhang, Ying
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (21)
  • [5] Quantifying Systematic RBE-Weighted Dose Uncertainty Arising from Multiple Variable RBE Models in Organ at Risk
    Koh, Wei Yang Calvin
    Tan, Hong Qi
    Ng, Yan Yee
    Lin, Yen Hwa
    Ang, Khong Wei
    Lew, Wen Siang
    Lee, James Cheow Lei
    Park, Sung Yong
    ADVANCES IN RADIATION ONCOLOGY, 2022, 7 (02)
  • [6] Inclusion of a variable RBE into proton and photon plan comparison for various fractionation schedules in prostate radiation therapy
    Oden, Jakob
    Eriksson, Kjell
    Toma-Dasu, Iuliana
    MEDICAL PHYSICS, 2017, 44 (03) : 810 - 822
  • [7] Simultaneous optimization of RBE-weighted dose and nanometric ionization distributions in treatment planning with carbon ions
    Burigo, Lucas N.
    Ramos-Mendez, Jose
    Bangert, Mark
    Schulte, Reinhard W.
    Faddegon, Bruce
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (01)
  • [8] Impact of potentially variable RBE in liver proton therapy
    Chen, Yizheng
    Grassberger, Clemens
    Li, Junli
    Hong, Theodore S.
    Paganetti, Harald
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (19)
  • [9] Uncertainty incorporated beam angle optimization for IMPT treatment planning
    Cao, Wenhua
    Lim, Gino J.
    Lee, Andrew
    Li, Yupeng
    Liu, Wei
    Zhu, X. Ronald
    Zhang, Xiaodong
    MEDICAL PHYSICS, 2012, 39 (08) : 5248 - 5256
  • [10] Clinical advantages of incorporating predicted weekly anatomy in IMPT optimization with reduced setup error
    Zhang, Ying
    Chan, Mark Ka Heng
    MEDICAL PHYSICS, 2024, : 9207 - 9216