Four-Dimensional Flow MRI for the Evaluation of Aortic Endovascular Graft: A Pilot Study

被引:0
作者
Righini, Paolo [1 ]
Secchi, Francesco [2 ,3 ]
Mazzaccaro, Daniela [1 ]
Giese, Daniel [4 ]
Galligani, Marina [1 ]
Avishay, Dor [1 ]
Capra, Davide [5 ]
Monti, Caterina Beatrice [5 ]
Nano, Giovanni [1 ,2 ]
机构
[1] IRCCS Policlin San Donato, Operat Unit Vasc & Endovascular Unit, Via Morandi 30, I-20097 San Donato Milanese, Italy
[2] Univ Milan, Dept Biomed Sci Hlth, Via Mangiagalli 31, I-20133 Milan, Italy
[3] IRCCS Policlin San Donato, Unit Radiol, Via Morandi 30, I-20097 San Donato Milanese, Italy
[4] Siemens Healthcare GmbH, Magnet Resonance, D-91050 Erlangen, Germany
[5] Univ Milan, Postgrad Sch Radiodiagnost, Via Festa Perdono 7, I-20122 Milan, Italy
关键词
thoracic aortic endovascular repair (TEVAR); four-dimensional (4D) flow magnetic resonance; thoracic aortic dissection; aortic coarctation; helical flow; vortical flow; endoleak; computational fluid dynamic (CFD); THORACIC AORTA; STENT-GRAFT; REPAIR; QUANTIFICATION; RISK;
D O I
10.3390/diagnostics13122113
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We aimed to explore the feasibility of 4D flow magnetic resonance imaging (MRI) for patients undergoing thoracic aorta endovascular repair (TEVAR). We retrospectively evaluated ten patients (two female), with a mean (& PLUSMN;standard deviation) age of 61 & PLUSMN; 20 years, undergoing MRI for a follow-up after TEVAR. All 4D flow examinations were performed using a 1.5-T system (MAGNETOM Aera, Siemens Healthcare, Erlangen, Germany). In addition to the standard examination protocol, a 4D flow-sensitive 3D spatial-encoding, time-resolved, phase-contrast prototype sequence was acquired. Among our cases, flow evaluation was feasible in all patients, although we observed some artifacts in 3 out of 10 patients. Three individuals displayed a reduced signal within the vessel lumen where the endograft was placed, while others presented with turbulent or increased flow. An aortic endograft did not necessarily hinder the visualization of blood flow through 4D flow sequences, although the graft could generate flow artifacts in some cases. A 4D Flow MRI may represent the ideal tool to follow up on both healthy subjects deemed to be at an increased risk based on their anatomical characteristics or patients submitted to TEVAR for whom a surveillance protocol with computed tomography angiography would be cumbersome and unjustified.
引用
收藏
页数:11
相关论文
共 36 条
[11]   In vitro evaluation of flow patterns and turbulent kinetic energy in trans-catheter aortic valve prostheses [J].
Giese, Daniel ;
Weiss, Kilian ;
Baessler, Bettina ;
Madershahian, Navid ;
Choi, Yeong-Hoon ;
Maintz, David ;
Bunck, Alexander C. .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2018, 31 (01) :165-172
[12]   Aortic 4D Flow: Quantification of Signal-to-Noise Ratio as a Function of Field Strength and Contrast Enhancement for 1.5T, 3T, and 7T [J].
Hess, Aaron T. ;
Bissell, Malenka M. ;
Ntusi, Ntobeko A. B. ;
Lewis, Andrew J. M. ;
Tunnicliffe, Elizabeth M. ;
Greiser, Andreas ;
Stalder, Aurelien F. ;
Francis, Jane M. ;
Myerson, Saul G. ;
Neubauer, Stefan ;
Robson, Matthew D. .
MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (05) :1864-1871
[13]   Initial experience characterizing a type I endoleak from velocity profiles using time-resolved three-dimensional phase-contrast MRI [J].
Hope, Thomas A. ;
Zarins, Christopher K. ;
Herfkens, Robert J. .
JOURNAL OF VASCULAR SURGERY, 2009, 49 (06) :1580-1584
[14]   Flow dynamics of type II endoleaks can determine sac expansion after endovascular aneurysm repair using four-dimensional flow-sensitive magnetic resonance imaging analysis [J].
Katahashi, Kazuto ;
Sano, Masaki ;
Takehara, Yasuo ;
Inuzuka, Kazunori ;
Sugiyama, Masataka ;
Alley, Marcus T. ;
Takeuchi, Hiroya ;
Unno, Naoki .
JOURNAL OF VASCULAR SURGERY, 2019, 70 (01) :107-+
[15]  
Liu Sophia Z, 2023, Radiol Case Rep, V18, P1037, DOI 10.1016/j.radcr.2022.12.033
[16]   Time-resolved three-dimensional phase-contrast MRI [J].
Markl, M ;
Chan, FP ;
Alley, MT ;
Wedding, KL ;
Draney, MT ;
Elkins, CJ ;
Parker, DW ;
Wicker, R ;
Taylor, CA ;
Herfkens, RJ ;
Pelc, NJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (04) :499-506
[17]   False lumen pressure estimation in type B aortic dissection using 4D flow cardiovascular magnetic resonance: comparisons with aortic growth [J].
Marlevi, David ;
Sotelo, Julio A. ;
Grogan-Kaylor, Ross ;
Ahmed, Yunus ;
Uribe, Sergio ;
Patel, Himanshu J. ;
Edelman, Elazer R. ;
Nordsletten, David A. ;
Burris, Nicholas S. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
[18]   Blood flow helical pattern in type III arch configuration as a potential risk factor for type B aortic dissection [J].
Marrocco-Trischitta, Massimiliano M. ;
Sturla, Francesco .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2022, 61 (01) :132-139
[19]   Computational Fluid Dynamics Modeling of Proximal Landing Zones for Thoracic Endovascular Aortic Repair in the Bovine Arch Variant [J].
Marrocco-Trischitta, Massimiliano M. ;
Romarowski, Rodrigo M. ;
Alaidroos, Moad ;
Sturla, Francesco ;
Glauber, Mattia ;
Nano, Giovanni .
ANNALS OF VASCULAR SURGERY, 2020, 69 :413-417
[20]   The Modified Arch Landing Areas Nomenclature predicts proximal endograft failure after thoracic endovascular aortic repair [J].
Marrocco-Trischitta, Massimiliano M. ;
de Beaufort, Hector W. ;
Piffaretti, Gabriele ;
Bonardelli, Stefano ;
Gargiulo, Mauro ;
Antonello, Michele ;
van Herwaarden, Joost A. ;
Boveri, Sara ;
Bellosta, Raffaello ;
Trimarchi, Santi .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2020, 58 (02) :309-318