An Adaptive Hybrid Control of Reduced Switch Multilevel Grid Connected Inverter for Weak Grid Applications

被引:13
作者
Muhammad, Tila [1 ]
Khan, Adnan Umar [1 ]
Abid, Yousra [1 ]
Khan, Muhammad Hilal [2 ]
Ullah, Nasim [3 ]
Blazek, Vojtech [4 ]
Prokop, Lukas [4 ]
Misak, Stanislav [4 ]
机构
[1] Int Islamic Univ Islamabad, Dept Elect & Comp Engn, Islamabad 44000, Pakistan
[2] City Univ Sci & Informat Technol, Dept Elect Engn, Peshawar 25000, Pakistan
[3] Taif Univ, Coll Engn, Dept Elect Engn, Taif 11099, Saudi Arabia
[4] VSB Tech Univ Ostrava, ENET Ctr, Ostrava 70800, Czech Republic
关键词
Power harmonic filters; Harmonic analysis; Multilevel inverters; Impedance; Feedforward systems; Switches; Power system stability; Adaptive harmonic compensators; grid-connected inverters; harmonic compensators; multilevel inverters; phase disposition level shift carrier pulse width modulation; reduced switch multilevel inverters; total harmonic distortion; weak grid; FEEDFORWARD; VOLTAGE;
D O I
10.1109/ACCESS.2023.3259323
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Grid-connected inverters have a very significant role in the integration of renewable energy resources with utility grids. However, in recent studies, it is revealed that grid-connected inverters are vulnerable to instability when the nature of the grid changes from strong to weak, which produces uncertainty and performance degradation. An increase in grid impedance decreases stability margins, tremendously increases total harmonic distortion after a certain limit, and amplifies the voltage harmonics in the grid. A cascaded reduced switch symmetrical multilevel inverter along with an adaptive hybrid control technique is proposed for injecting power generated from distributed energy resources efficiently and stably to the utility grid. This research contributes twofold: a multilevel inverter topology and the other is its control method. The multilevel inverter reduces total harmonic distortion and size of the filter while increasing power handling capability. The control unit of the proposed system further consists of two parts: one is the synchronous frame current controller, and the other is stationary frame adaptive harmonic compensators. The grid current controller which is working in a synchronous reference frame ensures regulated current injection to the grid. It is not favorable to implement a harmonic compensator in a synchronous reference frame due to computation complexities. Therefore, the stationary reference frame controllers are used for harmonic compensations. But the resultant harmonic compensators have narrow bandwidth. Thus, these are not robust against variation in grid frequency. In this research, this problem is resolved by adding the adaptive features within the harmonic compensators, which shift its passing band according to the frequency of the grid while remaining with the same bandwidth. The proposed design of the hybrid frame controller is validated by considering a nine-level inverter connected with a weak grid.
引用
收藏
页码:28103 / 28118
页数:16
相关论文
共 37 条
[1]  
[Anonymous], 2017, Integrating Inverter-based Resources Into Low Short Circuit Strength Systems
[2]   Step-by-Step Controller Design for LCL-Type Grid-Connected Inverter with Capacitor-Current-Feedback Active-Damping [J].
Bao, Chenlei ;
Ruan, Xinbo ;
Wang, Xuehua ;
Li, Weiwei ;
Pan, Donghua ;
Weng, Kailei .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) :1239-1253
[3]  
Batool Q., 2022, CIRCUIT WORLD, P1
[4]   Multilevel Inverter: A Survey on Classical and Advanced Topologies, Control Schemes, Applications to Power System and Future Prospects [J].
Choudhury, Subhashree ;
Bajaj, Mohit ;
Dash, Taraprasanna ;
Kamel, Salah ;
Jurado, Francisco .
ENERGIES, 2021, 14 (18)
[5]   Robust Current Control of Grid-Tied Inverters Affected by LCL Filter Soft-Saturation [J].
Dantas Osorio, Caio Ruviaro ;
Koch, Gustavo Guilherme ;
Pinheiro, Humberto ;
Oliveira, Ricardo C. L. F. ;
Montagner, Vinicius Foletto .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (08) :6550-6561
[6]   Review of grid connection requirements for generation assets in weak power grids [J].
Etxegarai, Agurtzane ;
Eguia, Pablo ;
Torres, Esther ;
Iturregi, Araitz ;
Valverde, Victor .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 41 :1501-1514
[7]   An Adaptive Resonant Regulator for Single-Phase Grid-Tied VSCs [J].
Golestan, Saeed ;
Ebrahimzadeh, Esmaeil ;
Guerrero, Josep M. ;
Vasquez, Juan. C. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (03) :1867-1873
[8]   PLL With MAF-Based Prefiltering Stage: Small-Signal Modeling and Performance Enhancement [J].
Golestan, Saeed ;
Guerrero, Josep M. ;
Vidal, Ana ;
Yepes, Alejandro G. ;
Doval-Gandoy, Jesus .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (06) :4013-4019
[9]  
Hasan S. T., 2022, IEEE T INSTRUM MEAS, V71, P1
[10]   Energy storage sizing for grid compatibility of intermittent renewable resources: A California case study [J].
Headley, Alexander J. ;
Copp, David A. .
ENERGY, 2020, 198