Validity of Wearable Monitors and Smartphone Applications for Measuring Steps in Semi-Structured and Free-Living Settings

被引:1
作者
Adamakis, Manolis [1 ]
机构
[1] Natl & Kapodistrian Univ Athens, Sch Phys Educ & Sport Sci, Dafne 17237, Greece
关键词
validity; accuracy; accelerometer; physical activity measurement; free-living monitoring; wearable monitor; activity tracker; consumer-level monitor; smartphone app; step count; INTRACLASS CORRELATION-COEFFICIENTS; PHYSICAL-ACTIVITY MONITORS; WORLDWIDE SURVEY; FITNESS TRENDS; RELIABILITY; ACTIGRAPH; DEVICES;
D O I
10.3390/technologies11010029
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Wearable technologies have become powerful tools for health and fitness and are indispensable everyday tools for many individuals; however, significant limitations exist related to the validity of the metrics these monitors purport to measure. Thus, the purpose of the present study was to validate the step count of three wearable monitors (i.e., Yamax 3D Power-Walker, Garmin Vivofit 3 and Medisana Vifit), as well as two Android apps (i.e., Accupedo Pedometer and Pedometer 2.0), in a sample of healthy adults. These monitors and apps were evaluated in a lab-based semi-structured study and a 3-day field study under habitual free-living conditions. A convenience sample of 24 healthy adults (14 males and 10 females; 32.6 +/- 2.5 years) participated in both studies. Direct step observation and Actigraph served as the criterion methods and validity was evaluated by comparing each monitor and app with the criterion measure using mean absolute percentage errors (MAPE), Bland-Altman plots, and Intraclass Correlation Coefficients. The results revealed high validity for the three wearable monitors during the semi-structured study, with MAPE values approximately 5% for Yamax and Vifit and well below 5% for Vivofit, while the two apps showed high MAPE values over 20%. In the free-living study all monitors and apps had high MAPE, over 10%. The lowest error was observed for Yamax, Vifit and Pedometer app, while Accupedo app had the highest error, overestimating steps by 32%. The present findings cannot support the value of wearable monitors and apps as acceptable measures of PA and step count in free-living contexts. Wearable monitors and apps that might be valid in one context, might not be valid in different contexts and vice versa, and researchers should be aware of this limitation.
引用
收藏
页数:11
相关论文
共 41 条
  • [31] Association of Daily Step Count and Step Intensity With Mortality Among US Adults
    Saint-Maurice, Pedro F.
    Troiano, Richard P.
    Bassett, David R., Jr.
    Graubard, Barry I.
    Carlson, Susan A.
    Shiroma, Eric J.
    Fulton, Janet E.
    Matthews, Charles E.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2020, 323 (12): : 1151 - 1160
  • [32] Validation and comparison of ActiGraph activity monitors
    Sasaki, Jeffer E.
    John, Dinesh
    Freedson, Patty S.
    [J]. JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2011, 14 (05) : 411 - 416
  • [33] Wearable activity trackers-advanced technology or advanced marketing?
    Shei, Ren-Jay
    Holder, Ian G.
    Oumsang, Alicia S.
    Paris, Brittni A.
    Paris, Hunter L.
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2022, 122 (09) : 1975 - 1990
  • [34] Mobile Apps to Quantify Aspects of Physical Activity: a Systematic Review on its Reliability and Validity
    Silva, Anabela G.
    Simoes, Patricia
    Queiros, Alexandra
    Rodrigues, Mario
    Rocha, Nelson P.
    [J]. JOURNAL OF MEDICAL SYSTEMS, 2020, 44 (02)
  • [35] Worldwide Survey of Fitness Trends for 2022
    Thompson, Walter R.
    [J]. ACSMS HEALTH & FITNESS JOURNAL, 2022, 26 (01) : 11 - 20
  • [36] Worldwide Survey of Fitness Trends for 2021
    Thompson, Walter R.
    [J]. ACSMS HEALTH & FITNESS JOURNAL, 2021, 25 (01) : 10 - 19
  • [37] WORLDWIDE SURVEY OF FITNESS TRENDS FOR 2020
    Thompson, Walter R.
    [J]. ACSMS HEALTH & FITNESS JOURNAL, 2019, 23 (06) : 10 - 18
  • [38] Validity of six consumer-level activity monitors for measuring steps in patients with chronic heart failure
    Vetrovsky, Tomas
    Siranec, Michal
    Marencakova, Jitka
    Tufano, James J.
    Capek, Vaclav
    Bunc, Vaclav
    Belohlavek, Jan
    [J]. PLOS ONE, 2019, 14 (09):
  • [39] Standardizing Analytic Methods and Reporting in Activity Monitor Validation Studies
    Welk, Gregory J.
    Bai, Yang
    Lee, Jung-Min
    Godino, Job
    Saint-Maurice, Pedro F.
    Carr, Lucas
    [J]. MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2019, 51 (08) : 1767 - 1780
  • [40] Statistical Methods Used to Test for Agreement of Medical Instruments Measuring Continuous Variables in Method Comparison Studies: A Systematic Review
    Zaki, Rafdzah
    Bulgiba, Awang
    Ismail, Roshidi
    Ismail, Noor Azina
    [J]. PLOS ONE, 2012, 7 (05):