Absorbed dose and image quality according to the scan mode and shield position in pediatric brain computed tomography scans

被引:1
|
作者
Bae, Eunmi [1 ]
Cho, Youngkwon [2 ]
Kim, Sungchul [3 ]
机构
[1] Korea Med Inst Suwon Ctr, Dept Diagnost Radiol, Suwon, Gyeonggi Do, South Korea
[2] Cheongju Univ, Coll Hlth Sci, Dept Radiol Sci, 298 Cheongwon Gu, Cheongju, Chungcheongbug, South Korea
[3] Gachon Univ Med Campus, Dept Radiol Sci, Hambakmoe Ro, Incheon, South Korea
关键词
CHILDREN; CHEST;
D O I
10.1093/rpd/ncad001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, computed tomography dose index (CTDIvol), dose-length product (DLP), organ dose and signal-to-noise ratio (SNR) were measured in pediatric brain helical and volumetric CT scans using a pediatric phantom (equivalent to a 10-year-old) and optically stimulated luminescence dosemeters (OSLD) as the scan protocol used in Hospital A. Volumetric scans showed lower CTDIvol, DLP and organ dose than helical scans, and the SNR showed similar results. The organ doses were lower in the phantoms protected with front, rear or front and rear shielding than in those without shielding. However, no statistically significant differences were found among the different shield locations. In pediatric brain CT scans, to reduce exposure dose and patient discomfort while maintaining image quality, a volumetric scan rather than a helical scan was preferred, and a good shielding effect was observed with front or rear shielding.
引用
收藏
页码:385 / 390
页数:6
相关论文
共 50 条
  • [41] Evaluation of image quality, organ doses, effective dose, and cancer risk from pediatric brain CT scans
    Kiani, M.
    Chaparian, A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 158
  • [42] Influence of phantom diameter, kVp and scan mode upon computed tomography dose index
    Nickoloff, EL
    Dutta, AK
    Lu, ZF
    MEDICAL PHYSICS, 2003, 30 (03) : 395 - 402
  • [43] Pragmatic approaches to reducing radiation dose in brain computed tomography scan using scan parameter modification
    Choopani, Mohammad Reza
    Abedi, Iraj
    Dalvand, Fatemeh
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2022, 12 (03): : 219 - 226
  • [44] Validation of Deep-Learning Image Reconstruction for Low-Dose Chest Computed Tomography Scan: Emphasis on Image Quality and Noise
    Kim, Joo Hee
    Yoon, Hyun Jung
    Lee, Eunju
    Kim, Injoong
    Cha, Yoon Ki
    Bak, So Hyeon
    KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (01) : 131 - 138
  • [45] Tradeoffs between radiation exposure to the lens of the eyes and diagnostic image quality in pediatric brain computed tomography
    Karami, Vahid
    Albosof, Mohsen
    Gholami, Mehrdad
    Adeli, Mohammad
    Hekmatnia, Ali
    Sheidaei, Mehdi Fallah Bagher
    Behbahani, Ali Taghizadeh
    Sharif, Hoda Sadat
    Jafrasteh, Somayeh
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2023, 13 (03): : 208 - 216
  • [46] Estimation of Absorbed Dose of the Thyroid Gland in Patients Undergoing 64-Slice Head Computed Tomography and Comparison the Results with ImPACT Software and Computed Tomography Scan Dose Index
    Maziar, Asghar
    Paydar, Reza
    Azadbakht, Ghazal
    Shahbazi-Gahrouei, Daryoush
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2019, 9 (03): : 190 - 195
  • [47] Estimated radiation dose and image quality comparison of the scan protocols in dual-source computed tomography coronary angiography
    Karaarslan, Ercan
    Ulus, Sila
    Bavbek, Cengiz
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2013, 57 (04) : 407 - 414
  • [48] Impact of Iterative Reconstruction Algorithms on Image Quality and Radiation Dose in Computed Tomography Scan of Patients with Malignant Pancreatic Lesions
    Asemanrafat, Mohamadhosein
    Chaparian, Ali
    Lotfi, Mehrzad
    Rasekhi, Alireza
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2022, 12 (01): : 69 - 75
  • [49] Image quality of spectral brain computed tomography angiography using halved dose of iodine contrast medium
    Veronica Fransson
    Helena Mellander
    Birgitta Ramgren
    Henrik Andersson
    Francesco Arena
    Kristina Ydström
    Teresa Ullberg
    Johan Wassélius
    Neuroradiology, 2023, 65 : 1333 - 1342
  • [50] Image quality of spectral brain computed tomography angiography using halved dose of iodine contrast medium
    Fransson, Veronica
    Mellander, Helena
    Ramgren, Birgitta
    Andersson, Henrik
    Arena, Francesco
    Ydstroem, Kristina
    Ullberg, Teresa
    Wasselius, Johan
    NEURORADIOLOGY, 2023, 65 (09) : 1333 - 1342