Absorbed dose and image quality according to the scan mode and shield position in pediatric brain computed tomography scans

被引:1
|
作者
Bae, Eunmi [1 ]
Cho, Youngkwon [2 ]
Kim, Sungchul [3 ]
机构
[1] Korea Med Inst Suwon Ctr, Dept Diagnost Radiol, Suwon, Gyeonggi Do, South Korea
[2] Cheongju Univ, Coll Hlth Sci, Dept Radiol Sci, 298 Cheongwon Gu, Cheongju, Chungcheongbug, South Korea
[3] Gachon Univ Med Campus, Dept Radiol Sci, Hambakmoe Ro, Incheon, South Korea
关键词
CHILDREN; CHEST;
D O I
10.1093/rpd/ncad001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, computed tomography dose index (CTDIvol), dose-length product (DLP), organ dose and signal-to-noise ratio (SNR) were measured in pediatric brain helical and volumetric CT scans using a pediatric phantom (equivalent to a 10-year-old) and optically stimulated luminescence dosemeters (OSLD) as the scan protocol used in Hospital A. Volumetric scans showed lower CTDIvol, DLP and organ dose than helical scans, and the SNR showed similar results. The organ doses were lower in the phantoms protected with front, rear or front and rear shielding than in those without shielding. However, no statistically significant differences were found among the different shield locations. In pediatric brain CT scans, to reduce exposure dose and patient discomfort while maintaining image quality, a volumetric scan rather than a helical scan was preferred, and a good shielding effect was observed with front or rear shielding.
引用
收藏
页码:385 / 390
页数:6
相关论文
共 50 条
  • [31] COMPARISON OF EFFECTIVE RADIATION DOSE IN PEDIATRIC HEAD COMPUTED TOMOGRAPHY SCANS BETWEEN COMMUNITY AND PEDIATRIC HOSPITALS
    Manley-Markowski, R. N.
    Stanford, K.
    Glasier, C.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2013, 61 (02) : 454 - 454
  • [32] Assessment of Radiation Dose and Image Quality of Multidetector Computed Tomography
    Al Ewaidat, Haytham
    Zheng, Xiaoming
    Khader, Yousef
    Abdelrahman, Mostafa
    Alhasan, Mostafa Khaled Mustafa
    Rawashdeh, Mohammad Ahmmad
    Al Mousa, Dana Samir
    Alawneh, Khaled Zayed Ali
    IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (03)
  • [33] IMAGE QUALITY AND PATIENT DOSE IN COMPUTED TOMOGRAPHY EXAMINATIONS IN GREECE
    Simantirakis, G.
    Hourdakis, C. J.
    Economides, S.
    Dimitriou, P.
    RADIATION PROTECTION DOSIMETRY, 2011, 147 (1-2) : 129 - 132
  • [34] Evaluation of surface dose and image quality using the half-scan mode in chest computed tomography-guided interventional radiology: a phantom study
    Hasegawa H.
    Sato J.
    Kobayashi I.
    Radiological Physics and Technology, 2018, 11 (2) : 138 - 148
  • [35] Abdominal Pediatric Cancer Surveillance Using Serial Computed Tomography: Evaluation of Organ Absorbed Dose and Effective Dose
    Lam, Diana
    Wootton-Gorges, Sandra L.
    McGahan, John P.
    Stern, Robin
    Boone, John M.
    SEMINARS IN ONCOLOGY, 2011, 38 (01) : 128 - 135
  • [36] Evaluation of the impact of organ-specific dose reduction on image quality in pediatric chest computed tomography
    Johannes Boos
    Patric Kröpil
    Dirk Klee
    Philipp Heusch
    Lars Schimmöller
    Jörg Schaper
    Gerald Antoch
    Rotem S. Lanzman
    Pediatric Radiology, 2014, 44 : 1065 - 1069
  • [37] Evaluation of the impact of organ-specific dose reduction on image quality in pediatric chest computed tomography
    Boos, Johannes
    Kroepil, Patric
    Klee, Dirk
    Heusch, Philipp
    Schimmoeller, Lars
    Schaper, Joerg
    Antoch, Gerald
    Lanzman, Rotem S.
    PEDIATRIC RADIOLOGY, 2014, 44 (09) : 1065 - 1069
  • [38] Evaluation of radiation dose and image quality for dental cone-beam computed tomography in pediatric patients
    Ito, Misaki
    Chida, Koichi
    Onodera, Shu
    Kojima, Ikuho
    Iikubo, Masahiro
    Kato, Toshiki
    Fujisawa, Masaki
    Zuguchi, Masayuki
    JOURNAL OF RADIOLOGICAL PROTECTION, 2023, 43 (03)
  • [39] Radiation dose optimization in pediatric temporal bone computed tomography: influence of tube tension on image contrast and image quality
    Nauer, Claude Bertrand
    Zubler, Christoph
    Weisstanner, Christian
    Stieger, Christof
    Senn, Pascal
    Arnold, Andreas
    NEURORADIOLOGY, 2012, 54 (03) : 247 - 254
  • [40] Radiation dose optimization in pediatric temporal bone computed tomography: influence of tube tension on image contrast and image quality
    Claude Bertrand Nauer
    Christoph Zubler
    Christian Weisstanner
    Christof Stieger
    Pascal Senn
    Andreas Arnold
    Neuroradiology, 2012, 54 : 247 - 254