Absorbed dose and image quality according to the scan mode and shield position in pediatric brain computed tomography scans

被引:1
|
作者
Bae, Eunmi [1 ]
Cho, Youngkwon [2 ]
Kim, Sungchul [3 ]
机构
[1] Korea Med Inst Suwon Ctr, Dept Diagnost Radiol, Suwon, Gyeonggi Do, South Korea
[2] Cheongju Univ, Coll Hlth Sci, Dept Radiol Sci, 298 Cheongwon Gu, Cheongju, Chungcheongbug, South Korea
[3] Gachon Univ Med Campus, Dept Radiol Sci, Hambakmoe Ro, Incheon, South Korea
关键词
CHILDREN; CHEST;
D O I
10.1093/rpd/ncad001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, computed tomography dose index (CTDIvol), dose-length product (DLP), organ dose and signal-to-noise ratio (SNR) were measured in pediatric brain helical and volumetric CT scans using a pediatric phantom (equivalent to a 10-year-old) and optically stimulated luminescence dosemeters (OSLD) as the scan protocol used in Hospital A. Volumetric scans showed lower CTDIvol, DLP and organ dose than helical scans, and the SNR showed similar results. The organ doses were lower in the phantoms protected with front, rear or front and rear shielding than in those without shielding. However, no statistically significant differences were found among the different shield locations. In pediatric brain CT scans, to reduce exposure dose and patient discomfort while maintaining image quality, a volumetric scan rather than a helical scan was preferred, and a good shielding effect was observed with front or rear shielding.
引用
收藏
页码:385 / 390
页数:6
相关论文
共 50 条
  • [21] The impact of pediatric-specific dose modulation curves on radiation dose and image quality in head computed tomography
    Joana Santos
    Shane Foley
    Graciano Paulo
    Mark F. McEntee
    Louise Rainford
    Pediatric Radiology, 2015, 45 : 1814 - 1822
  • [22] The impact of pediatric-specific dose modulation curves on radiation dose and image quality in head computed tomography
    Santos, Joana
    Foley, Shane
    Paulo, Graciano
    McEntee, Mark F.
    Rainford, Louise
    PEDIATRIC RADIOLOGY, 2015, 45 (12) : 1814 - 1822
  • [23] Bismuth breast-shield use in chest computed tomography for efficient dose reduction and sufficient image quality
    Ko, Chih-Hsiang
    Lee, Shiou-Ping
    Hsieh, Yi-Chien
    Lee, Yuan-Hao
    Yao, Melissa Min-Szu
    Chan, Wing P.
    MEDICINE, 2021, 100 (25) : E26277
  • [24] Deep learning image reconstruction in pediatric abdominal and chest computed tomography: a comparison of image quality and radiation dose
    Zhang, Kun
    Shi, Xiang
    Xie, Shuang-Shuang
    Sun, Ji-Hang
    Liu, Zhuo-Heng
    Zhang, Shuai
    Song, Jia-Yang
    Shen, Wen
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (06) : 3238 - +
  • [25] Experiences with image quality and radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in pediatric extremity trauma
    Tschauner, Sebastian
    Marterer, Robert
    Nagy, Eszter
    Singer, Georg
    Riccabona, Michael
    Sorantin, Erich
    SKELETAL RADIOLOGY, 2020, 49 (12) : 1939 - 1949
  • [26] Experiences with image quality and radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in pediatric extremity trauma
    Sebastian Tschauner
    Robert Marterer
    Eszter Nagy
    Georg Singer
    Michael Riccabona
    Erich Sorantin
    Skeletal Radiology, 2020, 49 : 1939 - 1949
  • [27] Image quality and absorbed dose comparison of single- and dual-source cone-beam computed tomography
    Miura, Hideharu
    Ozawa, Shuichi
    Okazue, Toshiya
    Kawakubo, Atsushi
    Yamada, Kiyoshi
    Nagata, Yasushi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (03): : 360 - 366
  • [28] Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality
    Geleijns, J.
    Salvado Artells, M.
    Veldkamp, W. J. H.
    Lopez Tortosa, M.
    Calzado Cantera, A.
    EUROPEAN RADIOLOGY, 2006, 16 (10) : 2334 - 2340
  • [29] Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality
    J. Geleijns
    M. Salvadó Artells
    W. J. H. Veldkamp
    M. López Tortosa
    A. Calzado Cantera
    European Radiology, 2006, 16 : 2334 - 2340
  • [30] Changing the Patient's Position: Pitfalls and Benefits for Radiation Dose and Image Quality of Computed Tomography in Polytrauma
    Graef, Jessica
    Bressem, Keno K.
    Asbach, Patrick
    Hamm, Bernd
    Niehues, Stefan M.
    DIAGNOSTICS, 2022, 12 (11)