Novel lateral flow assay for point-of-care detection of Neisseria gonorrhoeae infection in syndromic management settings: a cross-sectional performance evaluation

被引:9
|
作者
Peters, Remco P. H. [1 ,2 ,3 ]
Klausner, Jeffrey D. [4 ]
Mazzola, Laura [5 ]
Mdingi, Mandisa M. [1 ]
Jung, Hyunsul [2 ]
Gigi, Ranjana M. S. [1 ,6 ]
Piton, Jeremie [5 ]
Daniels, Joseph [7 ]
de Vos, Lindsey [1 ]
Adamson, Paul C. [8 ]
Gleeson, Birgitta [5 ]
Ferreyra, Cecilia [5 ]
机构
[1] Fdn Profess Dev, Res Unit, 16 Surrey Rd, East London, South Africa
[2] Univ Pretoria, Dept Med Microbiol, Pretoria, South Africa
[3] Univ Cape Town, Div Med Microbiol, Cape Town, South Africa
[4] Univ Southern Calif, Keck Sch Med, Dept Populat & Publ Hlth Sci, Los Angeles, CA USA
[5] Fdn Innovat New Diagnost FIND, Geneva, Switzerland
[6] Univ Bern, Dept Social & Prevent Med, Bern, Switzerland
[7] Arizona State Univ, Edson Coll Nursing & Hlth Innovat, Phoenix, AZ USA
[8] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA USA
基金
美国国家卫生研究院;
关键词
SEXUALLY-TRANSMITTED INFECTIONS; CHLAMYDIA-TRACHOMATIS; TRICHOMONAS-VAGINALIS; PCR; PREVENTION;
D O I
10.1016/S0140-6736(23)02240-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background A rapid and affordable point -of -care test is a priority for Neisseria gonorrhoeae control. WHO and Foundation for Innovative New Diagnostics (FIND) have a target product profile for a non -molecular N gonorrhoeae rapid point -of -care test that requires a clinical sensitivity of greater than 80% and a specificity over 95% to be considered useful in syndromic management; test turnaround time should be 30 min or under, and the test should cost less than US$3. A novel lateral flow assay (LFA) was developed to achieve that profile. Methods In this cross-sectional study we evaluated the performance of the novel N gonorrhoeae lateral flow assay (NG-LFA) at the primary health-care level in South Africa. Male patients with urethral discharge syndrome and female patients with vaginal discharge syndrome were recruited from five primary health-care facilities in the Buffalo City Metropolitan Municipality health district of South Africa. First -void urine specimens and nurse -collected vaginal swabs were tested in -facility with the NG-LFA and Xpert CT/NG PCR assay. N gonorrhoeae multi -antigen sequence typing (NG-MAST) was performed on all LFA positive specimens. Findings Between March 7, and Sept 19, 2022, we enrolled 200 male patients with urethral discharge and 200 female patients with vaginal discharge. The median age of male patients was 24 years (IQR 21-31 years), and the median age of female patients was 25 years (IQR 21-32 years). In addition, 23 male patients and 12 female patients who presented at the facility with a partner notification slip were enrolled of whom one (4%) and five (42%) were symptomatic, respectively. NG-LFA and Xpert results were available for all participants. In urine specimens, NG-LFA sensitivity was 96 center dot 1% (Wilson 95% CI 91 center dot 2-98 center dot 3; 123 LFA-positive among 128 PCR-positive specimens) and 91 center dot 7% in vaginal swab specimens (78 center dot 2-97 center dot 1; 33 LFA-positive among 36 PCR-positive). The specificity was 97 center dot 2% in urine specimens (90 center dot 4-99 center dot 2; 70 LFA-negative among 72 PCR-negative) and 96 center dot 3% in vaginal specimens (92 center dot 2-98 center dot 3; 158 LFA-negative among 164 PCR-negative). In 156 LFA-positive specimens, NG-MAST showed 93 different sequence types. Interpretation The novel NG-LFA had excellent clinical sensitivity and specificity in symptomatic male and female patients. The test met the optimal requirement for sensitivity and the minimal requirement for specificity specified in the target product profile. NG-LFA could provide an important tool to optimise clinical management and reduce excess antibiotic use in settings without direct access to laboratory testing. Funding Global Antimicrobial Resistance Innovation Fund (GAMRIF) via FIND and National Institutes of Health. Copyright (c) 2024 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license.
引用
收藏
页码:657 / 664
页数:8
相关论文
共 10 条
  • [1] Development of a Novel Fluorescent-Based Lateral Flow Assay for the Detection of Neisseria gonorrhoeae at the Point of Care
    Gleeson, Birgitta
    Piton, Jeremie
    Mazzola, Laura
    McHugh, Sean
    Bender, Jillian
    Lear, Madison
    Gavrikova, Tatyana
    Van Der Pol, Barbara
    Daniels, Brice
    Osborn, Jennifer
    Dailey, Peter
    Ferreyra, Cecilia
    SEXUALLY TRANSMITTED DISEASES, 2024, 51 (03) : 186 - 191
  • [2] Point-of-care tests for the diagnosis of Neisseria gonorrhoeae infection: a systematic review of operational and performance characteristics
    Smith, Lucy Alexandra Watchirs
    Hillman, Richard
    Ward, James
    Whiley, David M.
    Causer, Louise
    Skov, Steven
    Donovan, Basil
    Kaldor, John
    Guy, Rebecca
    SEXUALLY TRANSMITTED INFECTIONS, 2013, 89 (04) : 320 - 326
  • [3] Performance of a single-use, rapid, point-of-care PCR device for the detection of Neisseria gonorrhoeae, Chlamydia trachomatis, and Trichomonas vaginalis: a cross-sectional study
    Morris, Sheldon R.
    Bristow, Claire C.
    Wierzbicki, Michael R.
    Sarno, Mark
    Asbel, Lenore
    French, Audrey
    Gaydos, Charlotte A.
    Hazan, Lydie
    Mena, Leandro
    Madhivanan, Purnima
    Philip, Susan
    Schwartz, Saara
    Brown, Constance
    Styers, David
    Waymer, Toni
    Klausner, Jeffrey D.
    LANCET INFECTIOUS DISEASES, 2021, 21 (05) : 668 - 676
  • [4] Evaluation of a Hydrogel-Based Diagnostic Approach for the Point-of-Care Based Detection of Neisseria gonorrhoeae
    Perera, Sumudu R.
    Taheri, Ali
    Khan, Nurul H.
    Parti, Rajinder P.
    Stefura, Stephanie
    Skiba, Pauline
    Acker, Jason P.
    Martin, Irene
    Kusalik, Anthony
    Dillon, Jo-Anne R.
    ANTIBIOTICS-BASEL, 2018, 7 (03):
  • [5] A laboratory-based evaluation of the BioStar Optical ImmunoAssay point-of-care test for diagnosing Neisseria gonorrhoeae infection
    Samarawickrama, Amanda
    Alexander, Sarah
    Ison, Catherine
    JOURNAL OF MEDICAL MICROBIOLOGY, 2011, 60 (12) : 1779 - 1781
  • [6] Peer-delivered point-of-care testing for Chlamydia trachomatis and Neisseria gonorrhoeae within an urban community setting: a cross-sectional analysis
    Bell, Sara F. E.
    Coffey, Luke
    Debattista, Joseph
    Badman, Steven G.
    Redmond, Andrew M.
    Whiley, David M.
    Lemoire, Jime
    Williams, Owain D.
    Howard, Chris
    Gilks, Charles F.
    Dean, Judith A.
    SEXUAL HEALTH, 2020, 17 (04) : 359 - 367
  • [7] Targeted point-of-care testing compared with syndromic management of urogenital infections in women (WISH): a cross-sectional screening and diagnostic accuracy study
    Verwijs, Marijn C.
    Agaba, Stephen K.
    Sumanyi, Jean-Claude
    Umulisa, Marie Michele
    Mwambarangwe, Lambert
    Musengamana, Viateur
    Uwineza, Mireille
    Cuylaerts, Vicky
    Crucitti, Tania
    Jespers, Vicky
    van de Wijgert, Janneke H. H. M.
    LANCET INFECTIOUS DISEASES, 2019, 19 (06) : 658 - 669
  • [8] Multiplex Loop-Mediated Isothermal Amplification Coupled Lateral Flow Assay for Point-of-Care Detection of Syphilis
    Priya, Krishnamoorthy
    Saranya, Elangovan
    Kapoor, Ashish
    Ramya, Mohandass
    INDIAN JOURNAL OF MICROBIOLOGY, 2024, 64 (03) : 1246 - 1256
  • [9] Novel integration of lateral flow strip and point-of-care isothermal amplification techniques for meat adulteration detection: A comprehensive review
    Feng, Jinchao
    Lan, Hangzhen
    Wu, Zhen
    Pan, Daodong
    TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2024, 152
  • [10] A novel paper based loop mediated isothermal amplification and lateral flow assay (LAMP-LFA) for point-of-care detection of buffalo tissue origin in diverse foods
    Jawla, Jyoti
    Kumar, Rajiv Ranjan
    Mendiratta, Sanjod Kumar
    Agarwal, Ravi Kant
    Singh, Praveen
    Saxena, Vikas
    Kumari, Sarita
    Kumar, Dhananjay
    JOURNAL OF FOOD SAFETY, 2023, 43 (03)