Effect of macro-synthetic and hybrid fibres on the behaviour of square concrete columns reinforced with GFRP rebars under eccentric compression

被引:3
|
作者
Patil, Ganapati M. [1 ]
Prakash, S. Suriya [1 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Hyderabad, India
关键词
Eccentric compression; Fibre-reinforced concrete; GFRP reinforcement; Short RC columns; Hybrid fibres; FRP FABRIC REINFORCEMENT; FLEXURAL BEHAVIOR; STRENGTH; STEEL; BARS; FRACTURE; TESTS;
D O I
10.1016/j.istruc.2023.105707
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
GFRP rebars have emerged as a suitable alternative for steel rebars to tackle corrosion-related issues. However, the abrupt failure of GFRP-reinforced concrete (RC) elements due to the brittle behaviour of GFRP rebars is a significant concern. Fibre reinforced concrete (FRC) reduces brittleness by providing pseudo-ductility to GFRP RC members failing in compression. Moreover, fibre addition helps reduce crack widths by bridging them when subjected to tensile stresses. The current study aims to understand the influence of adding macro-synthetic Polyolefin (PO) and a hybrid mix of steel and PO fibres (HB) on the behaviour of GFRP-RC columns. Twentysix square columns reinforced with GFRP rebars and discrete fibres are tested. A low-eccentricity to-width ratio (e/d of 0.2) and a high-eccentricity to-width ratio (e/d of 0.4) are chosen as loading parameters. The test matrix includes the following specimens: i) control with no fibres, ii) only PO fibres, and iii) a hybrid mix of steel and PO fibres. Test results show that specimens reinforced with hybrid fibres outperformed macro-synthetic fibres in energy absorption and strength improvement. They also had better post-peak behaviour under eccentric compression. Fibre addition increased the load resistance contribution of GFRP rebars and prevented the complete spalling of concrete cover. It also improved the deformabilty factors when compared to control columns with no fibres under eccentric compression.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Behaviour of macro-synthetic fibers reinforced concrete: Experimental, numerical and design code investigations
    Nana, W. S. A.
    Tran, H., V
    Goubin, T.
    Kubisztal, G.
    Bennani, A.
    Bui, T. T.
    Cardia, G.
    Limam, A.
    STRUCTURES, 2021, 32 : 1271 - 1286
  • [22] Effect of stiffeners on the eccentric compression behaviour of square concrete-filled steel tubular columns
    Yuan, Fang
    Huang, Hong
    Chen, Mengcheng
    THIN-WALLED STRUCTURES, 2019, 135 (196-209) : 196 - 209
  • [23] Experimental Study on the Seismic Performance of Macro-Synthetic Fiber-Reinforced Concrete Ductile Columns
    Ma, Hua
    Wang, Honghuan
    Li, Zhenbao
    Sun, Xinyu
    Zhang, Xuewei
    TRENDS IN CIVIL ENGINEERING, PTS 1-4, 2012, 446-449 : 2345 - 2350
  • [24] Performance of Repaired Macro-Synthetic Structural Fibers and Glass-FRP-Reinforced Concrete Columns
    Sami, Abdul
    Khan, Qaiser Uz Zaman
    Azam, Asif
    Raza, Ali
    Berradia, Mohammed
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF CIVIL ENGINEERING, 2023, 47 (01) : 149 - 168
  • [25] Performance of Repaired Macro-Synthetic Structural Fibers and Glass-FRP-Reinforced Concrete Columns
    Abdul Sami
    Qaiser uz Zaman Khan
    Asif Azam
    Ali Raza
    Mohammed Berradia
    Iranian Journal of Science and Technology, Transactions of Civil Engineering, 2023, 47 : 149 - 168
  • [26] Pultruded GFRP square hollow columns with bolted sleeve joints under eccentric compression
    Xie, Lei
    Bai, Yu
    Qi, Yujun
    Wang, Hao
    COMPOSITES PART B-ENGINEERING, 2019, 162 : 274 - 282
  • [27] Behaviour of square FRP-Confined High-Strength Concrete Columns under Eccentric Compression
    Pour, Ali Fallah
    Gholampour, Aliakbar
    Zheng, Junai
    Ozbakkaloglu, Togay
    5TH ANNUAL INTERNATIONAL CONFERENCE ON MATERIAL SCIENCE AND ENVIRONMENTAL ENGINEERING (MSEE2017), 2018, 301
  • [28] Experimental study on the axial compression performance of GFRP-reinforced concrete square columns
    Tu, Jianwei
    Gao, Kui
    He, Lang
    Li, Xinping
    ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (07) : 1554 - 1565
  • [29] Structural Behavior of Circular Concrete Columns Reinforced with Longitudinal GFRP Rebars under Axial Load
    Sajedi, Seyed Fathollah
    Saffarian, Iman
    Pourbaba, Masoud
    Yeon, Jung Heum
    BUILDINGS, 2024, 14 (04)
  • [30] COMPRESSION BEHAVIOURS OF SPRAYED GFRP REINFORCED MASONRY COLUMNS UNDER CONCENTRIC AND ECCENTRIC LOADING
    Gu, Qian
    Zhang, Zhi
    Weng, Rui
    PROCEEDINGS OF THE ELEVENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOL I AND II, 2010, : 1298 - 1304