A Modified Technique for Transcatheter Pulmonary Valve Implantation of SAPIEN 3 Valves in Large Right Ventricular Outflow Tract: A Matched Comparison Study

被引:2
|
作者
Houeijeh, Ali [1 ,2 ]
Karsenty, Clement [1 ,3 ]
Combes, Nicolas [1 ,4 ]
Batteux, Clement [1 ,5 ]
Lecerf, Florence [1 ,5 ]
Remy, Frederic [1 ]
Valdeolmillos, Estibaliz [1 ,5 ]
Petit, Jerome [1 ]
Hascoet, Sebastien [1 ,5 ]
机构
[1] Univ Paris Saclay, Hop Marie Lannelongue, Ctr Reference Cardiopathies Congenitales Complexes, Fac Med,Grp Hosp Paris St Joseph,BME Lab, F-92350 Le Plessis Robinson, France
[2] Lille II Univ, Lille Univ Hosp, Pediat Cardiol Unit, Lab EA4489, F-59000 Lille, France
[3] Univ Toulouse, Hop Enfants, Cardiol Pediat & Congenitale, CHU Toulouse, F-31300 Toulouse, France
[4] Clin Pasteur, F-31300 Toulouse, France
[5] Univ Paris Saclay, Inserm, UMRS1180, F-92296 Le Plessis Robinson, France
关键词
pulmonary valve; infective endocarditis; melody; SAPIEN; congenital heart disease; VENUS P-VALVE; HEART-VALVE; PERCUTANEOUS IMPLANTATION; EARLY OUTCOMES; REPLACEMENT; CONDUIT; REGURGITATION; FEASIBILITY; DYSFUNCTION; EXPERIENCE;
D O I
10.3390/jcm12247656
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Percutaneous pulmonary valve implantation (PPVI) with a SAPIEN 3 valve is effective for treating treat right ventricle outflow (RVOT) dysfunction. A modified technique was developed without prestenting using a protective valve delivery method. We aimed to compare the procedural results of the modified technique group (MTG) to those of patients in a conventional technique group (CTG). Methods: We designed a matched before-after study. All consecutive PPVI with SAPIEN 3 performed in the MTG over 9 months were matched, based on the RVOT type and size, to consecutive procedures performed previously with SAPIEN 3. Results: A total of 54 patients were included, equally distributed in the two groups. The sizes of the SAPIEN 3 valves were 23 mm (n = 9), 26 mm (n = 9), 29 mm (n = 36). The two groups were similar regarding demographic data, RVOT type, and pre-procedure hemodynamics. PPVI was performed in a single procedure in all patients of the MTG, whereas six (22.2%) patients of the CTG group underwent prestenting as a first step and valve implantation later (p = 0.02). The procedures were successful in all cases. Stent embolization was reported in two patients (7.4%) in the CTG, which were impacted in pulmonary arteries. In one case (3.7%), in the MTG, an unstable 29 mm SAPIEN 3 valve was stabilized with two stents and additional valve-in-valve implantation. The hemodynamics results were good in all cases, without significant differences between the two groups. The procedures' durations and fluoroscopy times were significantly reduced in the MTG (48.1 versus 82.6 min, p < 0.0001; 15.2 versus 29.8 min, p = 0.0002). During follow-up, neither stent fracture nor valve dysfunction was noticed in either group. Conclusion: PPVI without prestenting and with a protective delivery method of the SAPIEN 3 valve significantly reduces the procedure's complexity, the duration, and the irradiation while maintaining excellent hemodynamics results in selected cases.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Transcatheter aortic valve implantation using Evolut PRO versus SAPIEN 3 valves: a randomized comparative trial
    Elnaggar, Heba M.
    Schoels, Wolfgang
    Mahmoud, Marwan S.
    Kishk, Yehia T.
    Kullmer, Matthias
    Dia, Mohamad
    Algowhary, Magdy
    REC-INTERVENTIONAL CARDIOLOGY, 2023, 5 (02): : 94 - 101
  • [42] Commentary: Transcatheter valve therapy for the right ventricular outflow tract: Right as rain, ready for Roger
    Said, Sameh M.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2021, 162 (03) : 973 - 974
  • [43] Procedural Results and Clinical Outcomes of Transcatheter Aortic Valve Implantation in Switzerland An Observational Cohort Study of Sapien 3 Versus Sapien XT Transcatheter Heart Valves
    Binder, Ronald K.
    Stortecky, Stefan
    Heg, Dik
    Tueller, David
    Jeger, Raban
    Toggweiler, Stefan
    Pedrazzini, Giovanni
    Amann, Franz W.
    Ferrari, Enrico
    Noble, Stephane
    Nietlispach, Fabian
    Maisano, Francesco
    Raber, Lorenz
    Roffi, Marco
    Grunenfelder, Jurg
    Juni, Peter
    Huber, Christoph
    Windecker, Stephan
    Wenaweser, Peter
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (10)
  • [44] Percutaneous pulmonary valve implantation for reconstruction of a patch-repaired right ventricular outflow tract
    Esmaeili, Anoosh
    Bollmann, Simone
    Khalil, Markus
    De Rosa, Roberta
    Fichtlscherer, Stephan
    Akintuerk, Hakan
    Schranz, Dietmar
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2018, 31 (01) : 106 - 111
  • [45] Impact of right ventricular outflow tract size and substrate on outcomes of percutaneous pulmonary valve implantation
    Boudjemline, Younes
    Sarquella-Brugada, Georgia
    Kamache, Issam
    Patel, Mehul
    Ladouceur, Magalie
    Bonnet, Damien
    Boughenou, Fazia-Marie
    Fraisse, Alain
    Lserin, Laurence
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2013, 106 (01) : 19 - 26
  • [46] Right ventricular outflow tract prestenting with AndraStent XXL before percutaneous pulmonary valve implantation
    Karsenty, Clement
    Malekzadeh-Milani, Sophie
    Fraisse, Alain
    Gewillig, Marc
    Bonnet, Damien
    Aldebert, Philippe
    Ovaert, Caroline
    Bouvaist, Helene
    Kempny, Aleksander
    Houeijeh, Ali
    Petit, Jerome
    Hascoet, Sebastien
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2020, 113 (02) : 113 - 120
  • [47] Conduction disorders after transcatheter aortic valve implantation: A comparison between SAPIEN 3 and SAPIEN 3 Ultra balloon-expandable valves
    Monizzi, Giovanni
    Olivares, Paolo
    Makmur, Giulio
    Fabbiocchi, Franco
    Grancini, Luca
    Mastrangelo, Angelo
    Ferrari, Cristina
    Galli, Stefano
    Montorsi, Piero
    Bartorelli, Antonio L. L.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [48] Changes in Speckle Tracking Echocardiography Measures of Ventricular Function after Percutaneous Implantation of the Edwards SAPIEN Transcatheter Heart Valve in the Pulmonary Position
    Chowdhury, Shahryar M.
    Hijazi, Ziyad M.
    Rhodes, John F.
    Kar, Saibal
    Makkar, Raj
    Mullen, Michael
    Cao, Qi-Ling
    Mandinov, Lazar
    Buckley, Jason
    Pietris, Nicholas P.
    Shirali, Girish S.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (03): : 461 - 469
  • [49] The adaptability of the Pulsta valve to the diverse main pulmonary artery shape of native right ventricular outflow tract disease
    Park, Woo Young
    Kim, Gi Beom
    Lee, Sang Yun
    Kim, Ah Young
    Choi, Jae Young
    Jang, So Ick
    Kim, Seong Ho
    Cha, Seul Gi
    Wang, Jou-Kou
    Lin, Ming-Tai
    Chen, Chun-An
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2024, 103 (04) : 587 - 596
  • [50] Pulmonary valve and right ventricular outflow tract surgery in adults: 23-year experience
    Szczechowicz, Marcin
    Mkalaluh, Sabreen
    Farag, Mina
    Mashhour, Ahmed
    Loukanov, Tsvetomir
    Kolcz, Jacek
    Karck, Matthias
    Weymann, Alexander
    KARDIOLOGIA POLSKA, 2018, 76 (03) : 602 - 610