Performance of global retention models in the optimisation of the chromatographic separation (I): Simple multi-analyte samples

被引:8
作者
Peiro-Vila, P. [1 ]
Villamonte, M. D. [2 ]
Lujan-Roca, I. [1 ]
Torres-Lapasio, J. R. [1 ]
Garcia-Alvarez-Coque, M. C. [1 ]
机构
[1] Univ Valencia, Fac Chem, Dept Analyt Chem, C Dr Moliner 50, Burjassot 46100, Spain
[2] Univ Mar Plata, Inst Invest Biol, CONICET, Mar Del Plata, Argentina
关键词
Global retention models; Multi -linear gradient elution; Optimisation of resolution; Multi-analyte samples; Modelling of unknowns; PHASE LIQUID-CHROMATOGRAPHY; OBJECTIVE FUNCTIONS; GENETIC ALGORITHMS; GRADIENT ELUTION; DECONVOLUTION;
D O I
10.1016/j.chroma.2022.463756
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Conventional retention models lead to accurate descriptions of the elution behaviour from the fitting of data for single solutes or from a set of solutes, one by one. However, the simultaneous fitting of several solutes through a regression process that separates the contributions of column and solvent from those of each solute is also possible. The result is a global retention model constituted by a set of equations with some common parameters (those associated with column and solvent), whereas others, specific to each solute, differ for each equation. This work explores the possibilities, advantages, and limitations of global models when they are applied to the optimisation of chromatographic resolution. A set constituted by 13 drugs (diuretics and beta-blockers) and a training experimental design of seven multi-linear gradients are considered. Since standards for all compounds were available, the optimisation based on global models could be compared with the conventional optimisation, which is based on individual models. In their current state, global models do not predict changes in elution order, but they do allow for incorporating additional solutes (e.g., new analytes or matrix peaks) with only one new experiment. This possibility is explored by extending the model for the 13 analytes to include 26 peaks associated with a contamination in the injector. The combination of individual and global models allows an optimisation where the effects of matrix peaks on the separation of analytes can be integrated.(c) 2022 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license ( http://creativecommons.org/licenses/by-nc-nd/4.0/ )
引用
收藏
页数:12
相关论文
共 42 条
[41]   Automatic program for peak detection and deconvolution of multi-overlapped chromatographic signals -: Part II:: Peak model and deconvolution algorithms [J].
Vivó-Truyols, G ;
Torres-Lapasió, JR ;
van Nederkassel, AM ;
Vander Heyden, Y ;
Massart, DL .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1096 (1-2) :146-155
[42]  
Worsfold P., 2019, ENCY ANAL SCI