A novel synthetic jet based heat sink with PCM filled cylindrical fins for efficient electronic cooling

被引:38
作者
Arumuru, Venugopal [1 ]
Rajput, Kartik [2 ]
Nandan, Rakesh [2 ]
Rath, Pransenjit [2 ]
Das, Mihir [2 ]
机构
[1] Indian Inst Technol, Sch Mech Sci, Appl Fluids Grp, Bhubaneswar 752050, India
[2] Indian Inst Technol, Sch Mech Sci, Bhubaneswar 752050, India
关键词
Heat sink; Phase change material (PCM); Electronic cooling; Synthetic jet; PHASE-CHANGE MATERIALS; PERFORMANCE;
D O I
10.1016/j.est.2022.106376
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The current electronic industries strive to build an effective cooling solution for modern compact electronic gadgets. The current experimental study, thus, focused on assessing the performance of a heat sink that combines the benefit of active and passive cooling utilizing the synthetic jet and Phase change material (PCM), respectively. The PCM offers a high latent heat value, whereas the synthetic jet induces vortices-based turbulent flow. The cooling characteristics of the heat sink filled with PCM and without PCM are evaluated when subjected to three different operating conditions, which are (i) natural convection, (ii) forced convection using DC fan, and (iii) forced convection using a synthetic jet. The PCM selected for the current study are Eicosane and 1-hexadecanol. It is observed that the inclusion of PCM into the heat sink improved its performance. The multiple-orifice synthetic jet outperformed the single-orifice synthetic jet. The steady-state base temperature attained by multiple orifice synthetic jet is 5 degrees C lower than that of the synthetic jet with a single orifice. The heat sink cooling performance is best when it is operated at its optimum height measured from the heat sink tip. Heat sink filled with Eicosane subjected to synthetic jet with multiple orifice showed best results, the thermal resistance, heat transfer coefficient and COP is found to be 0.91 K/W, 420.4 W/m2, and 2.1, respectively. The synthetic jet with multiple orifices performed better than the DC (Direct Current) fan operated at the same electrical power input of 0.5 W.
引用
收藏
页数:10
相关论文
共 44 条
[1]   An experimental study for thermal management using hybrid heat sinks based on organic phase change material, copper foam and heat pipe [J].
Ali, Hafiz Muhammad .
JOURNAL OF ENERGY STORAGE, 2022, 53
[2]   Thermal performance prediction of a phase change material based heat-sink cooling system for a printed circuit board, using response surface method [J].
Alshihmani, Hadeer ;
Maghrebi, Mohammad-Javad ;
Sardarabadi, Mohammad .
JOURNAL OF ENERGY STORAGE, 2022, 55
[3]   Synthetic jet actuators for heat transfer enhancement - A critical review [J].
Arshad, Adeel ;
Jabbal, Mark ;
Yan, Yuying .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 146 (146)
[4]  
Chandratilleke T.T., 2011, HEAT TRANSFER MATH M, P435
[5]   Heat Transfer Characteristics of a Heat Sink in Presence of a Synthetic Jet [J].
Chaudhari, Mangesh B. ;
Puranik, Bhalchandra ;
Agrawal, Amit .
IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2012, 2 (03) :457-463
[6]  
Dancova P., 2009, 7 WORLD C EXPT HEAT
[7]   A review on phase-change materials: Mathematical modeling and simulations [J].
Dutil, Yvan ;
Rousse, Daniel R. ;
Ben Salah, Nizar ;
Lassue, Stephane ;
Zalewski, Laurent .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (01) :112-130
[8]  
Elnaz E., 2022, JENERGY STORAGE, V50
[9]   Effects of melting temperature and the presence of internal fins on the performance of a phase change material (PCM)-based heat sink [J].
Fan, Li-Wu ;
Xiao, Yu-Qi ;
Zeng, Yi ;
Fang, Xin ;
Wang, Xiao ;
Xu, Xu ;
Yu, Zi-Tao ;
Hong, Rong-Hua ;
Hu, Ya-Cai ;
Cen, Ke-Fa .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2013, 70 :114-126
[10]   Thermal, flow and acoustic characteristics of the heat sink integrated inside the synthetic jet actuator cavity [J].
Gil, Pawel ;
Smyk, Emil ;
Galek, Rafal ;
Przeszlowski, Lukasz .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 170