Diffusion potentials in saturated hardened cement paste upon chloride exposure

被引:2
作者
Ziehensack, Elke [1 ]
Kessler, Sylvia [2 ]
Angst, Ueli [3 ]
Hilbig, Harald [1 ]
Gehlen, Christoph [1 ]
机构
[1] Tech Univ Munich, Ctr Bldg Mat, Franz Langinger Str 10, D-81245 Munich, Germany
[2] Univ Fed Armed Forces Hamburg, Helmut Schmidt Univ, Chair Engn Mat & Bldg Preservat, Holstenhofweg 85, D-22043 Hamburg, Germany
[3] Inst Bldg Mat IfB, Laura Hezner Weg 7, CH-8093 Zurich, Switzerland
关键词
Diffusion potential; Permselective behavior; Concrete; Hardened cement paste; Chloride; pH; ION-SELECTIVE ELECTRODES; PORE SOLUTION; REINFORCEMENT CORROSION; CATHODIC PROTECTION; LIQUID-JUNCTION; PART II; CONCRETE; STEEL; SLAG; EQUILIBRIUM;
D O I
10.1617/s11527-023-02184-y
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The diffusion potentials can cause significant errors in corrosion-related investigations of reinforced concrete structures (half-cell potential mapping, potentiometric sensors). Therefore, an improved understanding of the diffusion potentials in cement-based materials is needed. This study investigates the permselective behavior and its implication for the arising diffusion potentials. A diffusion cell is used to study the diffusion potentials in hardened cement pastes with imposed NaCl gradients. The cement pastes consist of ordinary Portland cement (OPC) and blast furnace cement (BFC) with water-cement ratios of 0.30-0.70. Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is used to determine the concentration profiles of Cl, Na, K and Ca in the cement pastes with a high spatial resolution (100 mu m). For the BFC pastes, considerable differences in the Cl- and Na+ mobilities are found, indicating their permselective behavior. Despite the permselective behavior, the measured diffusion potentials are small (- 6 to + 3 mV) for all investigated cement pastes due to the high pH levels (13-14) in the pore solutions. However, when using the diffusion cell, the pH differences interfere with the measured diffusion potentials. The interfering pH differences need to be considered for an accurate measurement of the diffusion potentials in cement pastes.
引用
收藏
页数:20
相关论文
共 69 条
[61]   The pore solution of blended cements: a review [J].
Vollpracht, Anya ;
Lothenbach, Barbara ;
Snellings, Ruben ;
Haufe, Johannes .
MATERIALS AND STRUCTURES, 2016, 49 (08) :3341-3367
[62]   The effect of simulated concrete pore solution composition and chlorides on the electronic properties of passive films on carbon steel rebar [J].
Williamson, Jon ;
Isgor, O. Burkan .
CORROSION SCIENCE, 2016, 106 :82-95
[63]   The relationship between pore structure and chloride diffusivity from ponding test in cement-based materials [J].
Yang, C. C. ;
Cho, S. W. ;
Wang, L. C. .
MATERIALS CHEMISTRY AND PHYSICS, 2006, 100 (2-3) :203-210
[64]   Presence and possible implications of a membrane potential in concrete exposed to chloride solution [J].
Zhang, JZ ;
Buenfeld, NR .
CEMENT AND CONCRETE RESEARCH, 1997, 27 (06) :853-859
[65]   Measurement and modelling of membrane potentials across OPC mortar specimens between 0.5 M NaCl and simulated pore solutions [J].
Zhang, JZ ;
Li, JY ;
Buenfeld, NR .
CEMENT & CONCRETE COMPOSITES, 2002, 24 (05) :451-455
[66]  
Zhang JZ, 2000, RILEM PROC, V19, P33
[67]   Measuring the membrane potential across cement-based materials [J].
Zhang, JZ ;
Buenfeld, NR .
MATERIALS AND STRUCTURES, 2000, 33 (232) :492-498
[68]   A state-of-the-art review on Ag/AgCl ion-selective electrode used for non-destructive chloride detection in concrete [J].
Zhang, Zhangmin ;
Hu, Jie ;
Ma, Yuwei ;
Wang, Yangyang ;
Huang, Haoliang ;
Zhang, Zuhua ;
Wei, Jiangxiong ;
Yin, Suhong ;
Yu, Qijun .
COMPOSITES PART B-ENGINEERING, 2020, 200
[69]  
Ziehensack E., 2017, ESTIMATION DIFFUSION