Air side performance of fin-and-tube heat exchangers with a hydrophilic layer under low-temperature frost-free conditions

被引:6
|
作者
Hu, Wanling [1 ,2 ]
Wang, Jing [1 ]
Zhang, Yibo [1 ]
Guan, Yong [1 ,3 ]
Lin, Yuanshan [1 ]
Zhao, Shengying [1 ]
机构
[1] Lanzhou Jiaotong Univ, Sch Environm & Municipal Engn, Lanzhou 730070, Peoples R China
[2] Lanzhou Jiaotong Univ, Key Lab Railway Vehicle Thermal Engn, Minist Educ China, Lanzhou 730070, Peoples R China
[3] Key Lab Yellow River Water Environm Gansu Prov, Lanzhou 730070, Peoples R China
基金
中国国家自然科学基金;
关键词
Air side performance; Correlations; Fin-and-tube heat exchangers; Low-temperature frost-free conditions; MASS-TRANSFER CHARACTERISTICS; WAVY FIN; FRICTION CHARACTERISTICS; WET; GREENHOUSE; NANOFLUID; FLOW;
D O I
10.1016/j.applthermaleng.2022.119532
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, to provide a reference for the application and thermal design of fin-and-tube heat exchangers (FTHEs) under low-temperature frost-free conditions (LTFFCs) and to improve the dehumidification performance of cooling dehumidifiers in greenhouse environments of low temperature and high humidity, the air side per-formance of FTHEs with a hydrophilic layer under LTFFCs was experimentally investigated. The experimental findings were compared with the results of ordinary temperature conditions (OTCs). The critical environmental conditions for frosting FTHEs were obtained. The applicability of existing performance prediction correlations under the LTFFCs was discussed and corrected. The findings show that at the same inlet temperature difference between air and refrigerant, the LTFFCs have smaller heat transfer rates than the OTCs. Varying inlet conditions showed that in the test conditions range, the test FTHEs are at risk of frosting when the inlet air relative humidity is 95 %, inlet air temperature is 281 K, frontal velocity is 1 m/s, and inlet refrigerant temperature is as low as 270 K. The data analysis revealed that existing correlations could not accurately predict the experimental data under LTFFCs. By adding the correction coefficients for temperature and relative humidity to existing correla-tions, the corrected correlations describe the experimental data for 90.6 % and 87.5 % of the heat transfer factor and mass transfer factor, respectively, within +/- 20 %, and the deviation of all friction factors is within +/- 10 %. The mean deviations of the heat transfer factor, mass transfer factor, and friction factor are 8.2 %, 10.8 %, and 4.8 %, respectively.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Air side heat transfer characteristics of plate finned tube heat exchangers with slit fin configuration under wet conditions
    Yun, Rin
    Kim, Yongbae
    Kim, Yongchan
    APPLIED THERMAL ENGINEERING, 2009, 29 (14-15) : 3014 - 3020
  • [32] Effect of fin pitches on the air-side performance of crimped spiral fin-and-tube heat exchangers with a multipass parallel and counter cross-flow configuration
    Pongsoi, Parinya
    Pikulkajorn, Santi
    Wang, Chi-Chuan
    Wongwises, Somchai
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (9-10) : 2234 - 2240
  • [33] Fin Pattern Effects on Air-Side Heat Transfer and Friction Characteristics of Fin-and-Tube Heat Exchangers with Large Number of Large-Diameter Tube Rows
    Tang, Ling-Hong
    Min, Zeng
    Xie, Gong-Nan
    Wang, Qiu-Wang
    HEAT TRANSFER ENGINEERING, 2009, 30 (03) : 171 - 180
  • [34] An experimental investigation on the airside performance of fin-and-tube heat exchangers having radial slit fins under wet condition
    Kim, Nae-Hyun
    JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2016, 11 (01):
  • [35] Thermal Performance of Elliptical Fin-and-Tube Heat Exchangers with Vortex Generator under Various Inclination Angles
    Wang, Yucheng
    Zhao, Wensheng
    Wang, Pengfei
    Jiang, Jin
    Luo, Xiangyu
    JOURNAL OF THERMAL SCIENCE, 2021, 30 (01) : 257 - 270
  • [36] Airside performance of fin-and-tube heat exchangers having sine wave fins under wet condition
    Kim, Nae-Hyun
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2015, 29 (09) : 4061 - 4070
  • [37] Air-side heat transfer enhancement in fin-tube heat exchangers using forced vibrations under various conditions
    Kim, Minjoong
    Han, Changho
    Baek, Changhyeon
    Kim, Yongchan
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2023, 144
  • [38] Research on the air-side thermal hydraulic performance of louvered fin and flat tube heat exchangers under low-pressure environment
    Wan, Rui
    Wang, Yichun
    Kavtaradze, Revaz
    Ji, Hongzeng
    He, Xinglei
    EXPERIMENTAL HEAT TRANSFER, 2020, 33 (01) : 81 - 99
  • [39] An experimental investigation on the airside performance of fin-and-tube heat exchangers having slit fins under wet condition
    Nae-Hyun Kim
    Taehun Kim
    Journal of Mechanical Science and Technology, 2015, 29 : 5011 - 5019
  • [40] Finite circular fin method for heat and mass transfer characteristics for plain fin-and-tube heat exchangers under fully and partially wet surface conditions
    Pirompugd, Worachest
    Wang, Chi-Chuan
    Wongwises, Somchai
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (3-4) : 552 - 565