Air side performance of fin-and-tube heat exchangers with a hydrophilic layer under low-temperature frost-free conditions

被引:6
|
作者
Hu, Wanling [1 ,2 ]
Wang, Jing [1 ]
Zhang, Yibo [1 ]
Guan, Yong [1 ,3 ]
Lin, Yuanshan [1 ]
Zhao, Shengying [1 ]
机构
[1] Lanzhou Jiaotong Univ, Sch Environm & Municipal Engn, Lanzhou 730070, Peoples R China
[2] Lanzhou Jiaotong Univ, Key Lab Railway Vehicle Thermal Engn, Minist Educ China, Lanzhou 730070, Peoples R China
[3] Key Lab Yellow River Water Environm Gansu Prov, Lanzhou 730070, Peoples R China
基金
中国国家自然科学基金;
关键词
Air side performance; Correlations; Fin-and-tube heat exchangers; Low-temperature frost-free conditions; MASS-TRANSFER CHARACTERISTICS; WAVY FIN; FRICTION CHARACTERISTICS; WET; GREENHOUSE; NANOFLUID; FLOW;
D O I
10.1016/j.applthermaleng.2022.119532
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, to provide a reference for the application and thermal design of fin-and-tube heat exchangers (FTHEs) under low-temperature frost-free conditions (LTFFCs) and to improve the dehumidification performance of cooling dehumidifiers in greenhouse environments of low temperature and high humidity, the air side per-formance of FTHEs with a hydrophilic layer under LTFFCs was experimentally investigated. The experimental findings were compared with the results of ordinary temperature conditions (OTCs). The critical environmental conditions for frosting FTHEs were obtained. The applicability of existing performance prediction correlations under the LTFFCs was discussed and corrected. The findings show that at the same inlet temperature difference between air and refrigerant, the LTFFCs have smaller heat transfer rates than the OTCs. Varying inlet conditions showed that in the test conditions range, the test FTHEs are at risk of frosting when the inlet air relative humidity is 95 %, inlet air temperature is 281 K, frontal velocity is 1 m/s, and inlet refrigerant temperature is as low as 270 K. The data analysis revealed that existing correlations could not accurately predict the experimental data under LTFFCs. By adding the correction coefficients for temperature and relative humidity to existing correla-tions, the corrected correlations describe the experimental data for 90.6 % and 87.5 % of the heat transfer factor and mass transfer factor, respectively, within +/- 20 %, and the deviation of all friction factors is within +/- 10 %. The mean deviations of the heat transfer factor, mass transfer factor, and friction factor are 8.2 %, 10.8 %, and 4.8 %, respectively.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Effect of fin thickness on the air-side performance of wavy fin-and-tube heat exchangers under dehumidifying conditions
    Kuvannarat, Thirapat
    Wang, Chi-Chuan
    Wongwises, Somchai
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2006, 49 (15-16) : 2587 - 2596
  • [2] Comparison of heat pump performance using fin-and-tube and microchannel heat exchangers under frost conditions
    Shao, Liang-Liang
    Yang, Liang
    Zhang, Chun-Lu
    APPLIED ENERGY, 2010, 87 (04) : 1187 - 1197
  • [3] Air-side performance of herringbone wavy fin-and-tube heat exchangers under dehumidifying condition - Data with larger diameter tube
    Wang, Chi-Chuan
    Liaw, Jane-Sunn
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (11-12) : 3054 - 3060
  • [4] Effect of fin pitches on the air-side performance of L-footed spiral fin-and-tube heat exchangers
    Pongsoi, Parinya
    Promoppatum, Patcharapit
    Pikulkajorn, Santi
    Wongwises, Somchai
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 59 : 75 - 82
  • [5] An experimental investigation of the air-side performance of crimped spiral fin-and-tube heat exchangers with a small tube diameter
    Keawkamrop, Hawatchai
    Asirvatham, Lazarus Godson
    Dalkilic, Ahmet Selim
    Ahn, Ho Seon
    Mahian, Omid
    Wongwi, Somchai
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 178
  • [6] Experimental and numerical investigation on air-side performance of fin-and-tube heat exchangers with various fin patterns
    Tang, L. H.
    Zeng, M.
    Wang, Q. W.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2009, 33 (05) : 818 - 827
  • [7] Air-side performance of serrated welded spiral fin-and-tube heat exchangers
    Kiatpachai, Parinya
    Pikulkajorn, Santi
    Wongwises, Somchai
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 89 : 724 - 732
  • [8] A comparison of the airside performance of the fin-and-tube heat exchangers in wet conditions; with and without hydrophilic coating
    Wang, CC
    Lee, WS
    Sheu, WJ
    Chang, YJ
    APPLIED THERMAL ENGINEERING, 2002, 22 (03) : 267 - 278
  • [9] Effect of fin thickness on air-side performance of herringbone wavy fin-and-tube heat exchangers
    Somchai Wongwises
    Yutasak Chokeman
    Heat and Mass Transfer, 2004, 41 : 147 - 154
  • [10] Effect of fin thickness on air-side performance of herringbone wavy fin-and-tube heat exchangers
    Wongwises, S
    Chokeman, Y
    HEAT AND MASS TRANSFER, 2004, 41 (02) : 147 - 154