Interrater reliability of a customized submaximal cycle ergometer test

被引:1
|
作者
Kantor, M. A. [1 ]
Fretti, S. [2 ]
Gubler, C. [3 ]
Kramer, M. [4 ]
Pettitt, R. W. [5 ]
机构
[1] Rocky Mt Univ Hlth Profess, Off Res & Sponsored Projects, Provo, UT 84601 USA
[2] Univ Cent Florida, Sch Kinesiol & Phys Therapy, Orlando, FL 32816 USA
[3] Nova Southeastern Univ, Ft Lauderdale, FL 33314 USA
[4] North West Univ, Phys Act Sport & Recreat PhASRec, Res Focus Area, Potchefstroom, South Africa
[5] Salt Lake Community Coll, Sch Hlth Sci, Salt Lake City, UT 84123 USA
关键词
Graded exercise testing; Indirect calorimetry; NIRS; Skeletal muscle oxygen saturation; (V) over dotO(2max); GAS-EXCHANGE THRESHOLD; ALL-CAUSE MORTALITY; CARDIORESPIRATORY FITNESS; OXYGEN-UPTAKE; EXERCISE; MUSCLE; MEN;
D O I
10.1007/s00421-022-05052-9
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Purpose Graded exercise testing (GXTs) is used to determine maximum oxygen uptake ((V) over dotO(2max)). Recently, customized submaximal exercise testing (CSET) completed on both treadmill and cycle ergometry were validated. Methods Interrater reliability of the CSET for cycle ergometry was examined. Thirteen participants (age 31 +/- 10.2 y, weight 77.9 +/- 10.5 kg, height 176.2 +/- 9.9 cm, body mass index 25.1 +/- 2.9) completed the 2-stage x 3-min CSET protocol performed by two separate testers. True (V) over dotO(2max) was determined using the highest value derived by a GXT and verification bout. Skeletal muscle oxygen saturation ((S) over dotmO(2)), measured using near-infrared spectrometry on the medial gastrocnemius muscle, and (V) over dotO(2) were monitored during each CSET; whereby, (V) over dotO(2) kinetics were modeled breath-by-breath data for each 3-min stage. Measurement agreement was quantified using intraclass coefficient (ICC), typical error (TE), and coefficient of variation (CV). Results "True" (V) over dotO(2max) (ml.kg(-l).min(-1)) between the GXT (41.3 +/- 10.5) and verification (42.5 +/- 11.5) was established (ICC = 0.98, TE: 0.98, CV 2.1%). Estimated (V) over dotO(2max) by tester 1 (42.5 +/- 9.8) and tester 2 (42.7 +/- 8.9) did not differ from "true" (V) over dotO(2max) (F-2,(36) =0.02, p = 0.98, eta(2) =0.00). The second stage evoked a (V) over dotO(2) slow component of 194 +/- 124 ml.min(-1) that corresponded with a time-dependent decline of (S) over dotmO(2). The mean (S) over dotmO(2) from the two CSET testers were highly correlated (ICC =0.91, TE: 4.1%, CV =8.9%). Conclusions The CSET is a reliable and valid procedure and (S) over dotmO(2 )is a useful tool for corroborating the second stage is in the heavy-intensity domain.
引用
收藏
页码:43 / 48
页数:6
相关论文
共 50 条
  • [41] Interrater reliability and discriminant validity of the Deductive Reasoning test
    Goverover, Y
    Hinojosa, J
    AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 2004, 58 (01): : 104 - 108
  • [42] Normative data and interrater reliability of the Design Fluency Test
    Carter, SL
    Shore, D
    Harnadek, MCS
    Kubu, CS
    CLINICAL NEUROPSYCHOLOGIST, 1998, 12 (04) : 531 - 534
  • [43] Interrater and intrarater reliability in multiple sleep latency test
    Chen, L.
    Ho, C. K. W.
    Lam, V. K. H.
    Fong, S. Y. Y.
    Li, A. M.
    Lam, S. P.
    Wing, Y. K.
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2008, 25 (04) : 218 - 221
  • [44] NORMAL STANDARDS FOR AN INCREMENTAL PROGRESSIVE CYCLE ERGOMETER TEST
    JONES, NL
    MAKRIDES, L
    HITCHCOCK, C
    CHYPCHAR, T
    MCCARTNEY, N
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1985, 131 (05): : 700 - 708
  • [45] VALIDITY OF DIFFERENT ANAEROBIC TEST PROTOCOLS ON THE CYCLE ERGOMETER
    BACHL, N
    GRANTSCHAROV, N
    IWANOFF, I
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1985, 6 (04) : 245 - 245
  • [46] Reliability Of A Newly Developed Cycle Ergometer For Estimating Cardiorespiratory Fitness
    Sawada, Susumu S.
    Dimitroff, Serena A.
    Sano, Fumi
    Nakazawa, Yuki
    Zhai, Xiangyu
    Koriyama, Sakura
    Kurosawa, Sayaka
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2023, 55 (09) : 710 - 710
  • [47] Cycle Ergometer Tests in Children With Cystic Fibrosis: Reliability and Feasibility
    Kent, Lisa
    O'Neill, Brenda
    Davison, Gareth
    Nevill, Alan
    Murray, Joyce
    Reid, Alastair
    Elborn, J. Stuart
    Bradley, Judy M.
    PEDIATRIC PULMONOLOGY, 2012, 47 (12) : 1226 - 1234
  • [48] The Submaximal Lateral Shuffle Test: A reliability and sensitivity analysis
    Maurus, Philipp
    Asmussen, Michael J.
    Cigoja, Sasa
    Nigg, Sandro R.
    Nigg, Benno M.
    JOURNAL OF SPORTS SCIENCES, 2019, 37 (18) : 2066 - 2074
  • [49] RELIABILITY OF A CYCLE ERGOMETER PEAK POWER TEST IN RUNNING-BASED TEAM SPORT ATHLETES: A TECHNICAL REPORT
    Wehbe, George M.
    Gabbett, Tim J.
    Hartwig, Timothy B.
    Mclellan, Christopher P.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2015, 29 (07) : 2050 - 2055
  • [50] Reliability of the submaximal iSTEP performance test in children with haemophilia
    Chugh, Deepti
    Thorpe, Nicola
    Alderson, Lucy
    Main, Eleanor
    Bladen, Melanie
    HAEMOPHILIA, 2022, 28 (01) : E5 - E8