Interrater reliability of a customized submaximal cycle ergometer test

被引:1
|
作者
Kantor, M. A. [1 ]
Fretti, S. [2 ]
Gubler, C. [3 ]
Kramer, M. [4 ]
Pettitt, R. W. [5 ]
机构
[1] Rocky Mt Univ Hlth Profess, Off Res & Sponsored Projects, Provo, UT 84601 USA
[2] Univ Cent Florida, Sch Kinesiol & Phys Therapy, Orlando, FL 32816 USA
[3] Nova Southeastern Univ, Ft Lauderdale, FL 33314 USA
[4] North West Univ, Phys Act Sport & Recreat PhASRec, Res Focus Area, Potchefstroom, South Africa
[5] Salt Lake Community Coll, Sch Hlth Sci, Salt Lake City, UT 84123 USA
关键词
Graded exercise testing; Indirect calorimetry; NIRS; Skeletal muscle oxygen saturation; (V) over dotO(2max); GAS-EXCHANGE THRESHOLD; ALL-CAUSE MORTALITY; CARDIORESPIRATORY FITNESS; OXYGEN-UPTAKE; EXERCISE; MUSCLE; MEN;
D O I
10.1007/s00421-022-05052-9
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Purpose Graded exercise testing (GXTs) is used to determine maximum oxygen uptake ((V) over dotO(2max)). Recently, customized submaximal exercise testing (CSET) completed on both treadmill and cycle ergometry were validated. Methods Interrater reliability of the CSET for cycle ergometry was examined. Thirteen participants (age 31 +/- 10.2 y, weight 77.9 +/- 10.5 kg, height 176.2 +/- 9.9 cm, body mass index 25.1 +/- 2.9) completed the 2-stage x 3-min CSET protocol performed by two separate testers. True (V) over dotO(2max) was determined using the highest value derived by a GXT and verification bout. Skeletal muscle oxygen saturation ((S) over dotmO(2)), measured using near-infrared spectrometry on the medial gastrocnemius muscle, and (V) over dotO(2) were monitored during each CSET; whereby, (V) over dotO(2) kinetics were modeled breath-by-breath data for each 3-min stage. Measurement agreement was quantified using intraclass coefficient (ICC), typical error (TE), and coefficient of variation (CV). Results "True" (V) over dotO(2max) (ml.kg(-l).min(-1)) between the GXT (41.3 +/- 10.5) and verification (42.5 +/- 11.5) was established (ICC = 0.98, TE: 0.98, CV 2.1%). Estimated (V) over dotO(2max) by tester 1 (42.5 +/- 9.8) and tester 2 (42.7 +/- 8.9) did not differ from "true" (V) over dotO(2max) (F-2,(36) =0.02, p = 0.98, eta(2) =0.00). The second stage evoked a (V) over dotO(2) slow component of 194 +/- 124 ml.min(-1) that corresponded with a time-dependent decline of (S) over dotmO(2). The mean (S) over dotmO(2) from the two CSET testers were highly correlated (ICC =0.91, TE: 4.1%, CV =8.9%). Conclusions The CSET is a reliable and valid procedure and (S) over dotmO(2 )is a useful tool for corroborating the second stage is in the heavy-intensity domain.
引用
收藏
页码:43 / 48
页数:6
相关论文
共 50 条
  • [31] Intrarater and interrater reliability of the modified Thomas Test
    Cady, K.
    Powis, M.
    Hopgood, K.
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2022, 29 : 86 - 91
  • [32] Interrater Reliability of the Star Excursion Balance Test
    Gribble, Phillip A.
    Kelly, Sarah E.
    Refshauge, Kathryn M.
    Hiller, Claire E.
    JOURNAL OF ATHLETIC TRAINING, 2013, 48 (05) : 621 - 626
  • [33] Intrarater and interrater reliability of the modified Thomas Test
    Cady, K.
    Powis, M.
    Hopgood, K.
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2022, 29 : 86 - 91
  • [34] A CYCLE ERGOMETER TEST OF MAXIMAL AEROBIC POWER
    MYLES, WS
    TOFT, RJ
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1982, 49 (01) : 121 - 129
  • [35] EVALUATION OF THE ACSM SUBMAXIMAL ERGOMETER TEST FOR ESTIMATING VO2MAX
    GREIWE, JS
    KAMINSKY, LA
    WHALEY, MH
    DWYER, GB
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1995, 27 (09): : 1315 - 1320
  • [36] Test of Intrarater and Interrater Reliability for the Star Excursion Balance Test
    Hyong, In Hyouk
    Kim, Jae Hyun
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2014, 26 (08) : 1139 - 1141
  • [37] Identification of critical intensity from a single lactate measure during a 3-min, submaximal cycle-ergometer test
    Fontana, Federico Y.
    Colosio, Alessandro L.
    Keir, Daniel A.
    Murias, Juan M.
    Pogliaghi, Silvia
    JOURNAL OF SPORTS SCIENCES, 2017, 35 (22) : 2191 - 2197
  • [38] Reliability of a Submaximal Field Test in Wheelchair Rugby
    Grossmann, Fabian
    Perret, Claudio
    Roelands, Bart
    Meeusen, Romain
    Flueck, Joelle Leonie
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2023, 44 (03) : 192 - 198
  • [39] Peak and submaximal physiologic responses following electrical stimulation leg cycle ergometer training
    Hooker, SP
    Scremin, AME
    Mutton, DL
    Kunkel, CF
    Cagle, G
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 1995, 32 (04): : 361 - 366
  • [40] Interrater and Intrarater Reliability' of the Active Hip Abduction Test
    Davis, Alice M.
    Bridge, Patrick
    Miller, Jason
    Nelson-Wong, Erika
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2011, 41 (12): : 953 - 960