Interrater reliability of a customized submaximal cycle ergometer test

被引:1
|
作者
Kantor, M. A. [1 ]
Fretti, S. [2 ]
Gubler, C. [3 ]
Kramer, M. [4 ]
Pettitt, R. W. [5 ]
机构
[1] Rocky Mt Univ Hlth Profess, Off Res & Sponsored Projects, Provo, UT 84601 USA
[2] Univ Cent Florida, Sch Kinesiol & Phys Therapy, Orlando, FL 32816 USA
[3] Nova Southeastern Univ, Ft Lauderdale, FL 33314 USA
[4] North West Univ, Phys Act Sport & Recreat PhASRec, Res Focus Area, Potchefstroom, South Africa
[5] Salt Lake Community Coll, Sch Hlth Sci, Salt Lake City, UT 84123 USA
关键词
Graded exercise testing; Indirect calorimetry; NIRS; Skeletal muscle oxygen saturation; (V) over dotO(2max); GAS-EXCHANGE THRESHOLD; ALL-CAUSE MORTALITY; CARDIORESPIRATORY FITNESS; OXYGEN-UPTAKE; EXERCISE; MUSCLE; MEN;
D O I
10.1007/s00421-022-05052-9
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Purpose Graded exercise testing (GXTs) is used to determine maximum oxygen uptake ((V) over dotO(2max)). Recently, customized submaximal exercise testing (CSET) completed on both treadmill and cycle ergometry were validated. Methods Interrater reliability of the CSET for cycle ergometry was examined. Thirteen participants (age 31 +/- 10.2 y, weight 77.9 +/- 10.5 kg, height 176.2 +/- 9.9 cm, body mass index 25.1 +/- 2.9) completed the 2-stage x 3-min CSET protocol performed by two separate testers. True (V) over dotO(2max) was determined using the highest value derived by a GXT and verification bout. Skeletal muscle oxygen saturation ((S) over dotmO(2)), measured using near-infrared spectrometry on the medial gastrocnemius muscle, and (V) over dotO(2) were monitored during each CSET; whereby, (V) over dotO(2) kinetics were modeled breath-by-breath data for each 3-min stage. Measurement agreement was quantified using intraclass coefficient (ICC), typical error (TE), and coefficient of variation (CV). Results "True" (V) over dotO(2max) (ml.kg(-l).min(-1)) between the GXT (41.3 +/- 10.5) and verification (42.5 +/- 11.5) was established (ICC = 0.98, TE: 0.98, CV 2.1%). Estimated (V) over dotO(2max) by tester 1 (42.5 +/- 9.8) and tester 2 (42.7 +/- 8.9) did not differ from "true" (V) over dotO(2max) (F-2,(36) =0.02, p = 0.98, eta(2) =0.00). The second stage evoked a (V) over dotO(2) slow component of 194 +/- 124 ml.min(-1) that corresponded with a time-dependent decline of (S) over dotmO(2). The mean (S) over dotmO(2) from the two CSET testers were highly correlated (ICC =0.91, TE: 4.1%, CV =8.9%). Conclusions The CSET is a reliable and valid procedure and (S) over dotmO(2 )is a useful tool for corroborating the second stage is in the heavy-intensity domain.
引用
收藏
页码:43 / 48
页数:6
相关论文
共 50 条
  • [1] Interrater reliability of a customized submaximal cycle ergometer test
    M. A. Kantor
    S. Fretti
    C. Gubler
    M. Kramer
    R. W. Pettitt
    European Journal of Applied Physiology, 2023, 123 : 43 - 48
  • [2] Validity And Reliability Of The Ymca Submaximal Cycle Test Using An Electrically-braked Ergometer
    Kidd, Justin
    Luden, Nicholas D.
    Saunders, Michael J.
    Womack, Christopher J.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 936 - 936
  • [3] A new submaximal cycle ergometer test for prediction of VO2max
    Ekblom-Bak, E.
    Bjorkman, F.
    Hellenius, M-L.
    Ekblom, B.
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2014, 24 (02) : 319 - 326
  • [4] Reliability Of A Submaximal Cycle Ergometer Verification Phase To Confirm VO2max
    Thornhill, Kirsten
    Sawyer, Brandon
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 40 - 40
  • [5] CHANGE IN OXYGEN-CONSUMPTION IN COLD CLIMATE ASSESSED WITH A SUBMAXIMAL CYCLE ERGOMETER TEST
    KOWALSKI, K
    REED, L
    VANTUYL, M
    HARFORD, R
    HOMER, L
    FASEB JOURNAL, 1992, 6 (05): : A1830 - A1830
  • [6] Estimation of energy expenditure in healthy adults from the YMCA Submaximal Cycle Ergometer Test
    Garatachea, Nuria
    Cavalcanti, Euclides
    Garcia-Lopez, David
    Gonzalez-Gallego, Javier
    de Paz, Jose A.
    EVALUATION & THE HEALTH PROFESSIONS, 2007, 30 (02) : 138 - 149
  • [7] The ability of a submaximal cycle ergometer test to detect longitudinal changes in VO2max
    Frida Björkman
    Örjan Ekblom
    Elin Ekblom-Bak
    Tony Bohman
    BMC Sports Science, Medicine and Rehabilitation, 13
  • [8] The Reliability of a 30-s Sprint Test on the Wattbike Cycle Ergometer
    Driller, Matthew W.
    Argus, Christos K.
    Shing, Cecilia M.
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2013, 8 (04) : 379 - 383
  • [9] The ability of a submaximal cycle ergometer test to detect longitudinal changes in VO2max
    Bjorkman, Frida
    Ekblom, Orjan
    Ekblom-Bak, Elin
    Bohman, Tony
    BMC SPORTS SCIENCE MEDICINE AND REHABILITATION, 2021, 13 (01)
  • [10] Reliability of a 2-Bout Exercise Test on a Wattbike Cycle Ergometer
    Driller, Matthew W.
    Argus, Christos K.
    Bartram, Jason C.
    Bonaventura, Jacinta
    Martin, David T.
    West, Nicholas P.
    Halson, Shona L.
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2014, 9 (02) : 340 - 345