Preoperative Assessment of Perianal Fistulas with Combined Magnetic Resonance and Tridimensional Endoanal Ultrasound: A Prospective Study

被引:3
作者
Varsamis, Nikolaos [1 ]
Kosmidis, Christoforos [1 ]
Chatzimavroudis, Grigorios [2 ]
Kiouti, Fani Apostolidou [3 ]
Efthymiadis, Christoforos [4 ]
Lalas, Vasilis [5 ]
Mystakidou, Chrysi Maria [6 ]
Sevva, Christina [1 ]
Papadopoulos, Konstantinos [1 ]
Anthimidis, George [7 ]
Koulouris, Charilaos [1 ]
Karakousis, Alexandros Vasileios [1 ]
Sapalidis, Konstantinos [1 ]
Kesisoglou, Isaak [1 ]
机构
[1] Aristotle Univ Thessaloniki, AHEPA Univ Hosp, Med Fac, Surg Dept 3, 1 Kiriakidi St, Thessaloniki 54636, Greece
[2] Aristotle Univ Thessaloniki, G Gennimatas Univ Hosp, Med Fac, Surg Dept 2, 41 Eth Aminis Steet, Thessaloniki 54635, Greece
[3] Aristotle Univ Thessaloniki, Med Fac, Biostat Unit, Thessaloniki 54124, Greece
[4] St Lukes Hosp, Surg Dept, Thessaloniki 55236, Greece
[5] Euromed Diagnost Ctr, Radiol Dept, 35 Gr Lampraki & Ag Dimitriou St, Thessaloniki 54638, Greece
[6] Aristotle Univ Thessaloniki, Fac Med, Thessaloniki 54124, Greece
[7] European Interbalkan Med Ctr, Surg Dept, 10 Asklipiou St, Thessaloniki 55535, Greece
关键词
perianal fistula; magnetic resonance imaging; tridimensional endoanal ultrasound; ANAL FISTULA; IN-ANO; SURGICAL-TREATMENT; PREDICTIVE-VALUE; RISK-FACTORS; MANAGEMENT; MRI; ENDOSONOGRAPHY; ABSCESS; CLASSIFICATION;
D O I
10.3390/diagnostics13172851
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: we designed a prospective study of diagnostic accuracy that compared pelvic MRI and 3D-EAUS with pelvic MRI alone in the preoperative evaluation and postoperative outcomes of patients with perianal fistulas. Methods: the sample size was 72 patients and this was divided into two imaging groups. MRI alone was performed on the first group. Both MRI and 3D-EAUS were performed in parallel on the second group. Surgical exploration took place after two weeks and was the standard reference. Park's classification, the presence of a concomitant abscess or a secondary tract, and the location of the internal opening were recorded. All patients were re-evaluated for complete fistula healing and fecal incontinence six months postoperatively. All of the collected data were subjected to statistical analysis. Results: the MRI group included 36 patients with 42 fistulas. The MRI + 3D-EAUS group included 36 patients with 46 fistulas. The adjusted sensitivity and negative predictive value were 1.00 for most fistula types in the group that underwent combined imaging. The adjusted specificity improved for intersphincteric fistulas in the same group. The adjusted balanced accuracy improved for all fistula types except rectovaginal. The combination of imaging methods showed improved diagnostic accuracy only in the detection of a secondary tract. The healing rate at six months was 100%. Fecal incontinence at six months did not present a statistically significant difference between the two groups (Fisher's exact test p-value > 0.9). Patients with complex perianal fistulas had a statistically significant higher probability of undergoing a second surgery (x(2) test p-value = 0.019). Conclusions: the combination of pelvic MRI and 3D-EAUS showed improved metrics of diagnostic accuracy and should be used in the preoperative evaluation of all patients with perianal fistulas, especially those with complex types.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Preoperative assessment of simple and complex anorectal fistulas: Tridimensional endoanal ultrasound? Magnetic resonance? Both?
    Brillantino, Antonio
    Iacobellis, Francesca
    Reginelli, Alfonso
    Monaco, Luigi
    Sodano, Biagio
    Tufano, Giuseppe
    Tufano, Antonio
    Maglio, Mauro
    De Palma, Maurizio
    Di Martino, Natale
    Renzi, Adolfo
    Grassi, Roberto
    RADIOLOGIA MEDICA, 2019, 124 (05): : 339 - 349
  • [2] Role of tridimensional endoanal ultrasound (3D-EAUS) in the preoperative assessment of perianal sepsis
    Brillantino, Antonio
    Iacobellis, Francesca
    Di Sarno, Giandomenico
    D'Aniello, Francesco
    Izzo, Domenico
    Paladino, Fiorella
    De Palma, Maurizio
    Castriconi, Maurizio
    Grassi, Roberto
    Di Martino, Natale
    Renzi, Adolfo
    INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 2015, 30 (04) : 535 - 542
  • [3] Role of tridimensional endoanal ultrasound (3D-EAUS) in the preoperative assessment of perianal sepsis
    Antonio Brillantino
    Francesca Iacobellis
    Giandomenico Di Sarno
    Francesco D’Aniello
    Domenico Izzo
    Fiorella Paladino
    Maurizio De Palma
    Maurizio Castriconi
    Roberto Grassi
    Natale Di Martino
    Adolfo Renzi
    International Journal of Colorectal Disease, 2015, 30 : 535 - 542
  • [4] Endoanal ultrasound in perianal fistulas and abscesses
    Felt-Bersma, R. J. F.
    DIGESTIVE AND LIVER DISEASE, 2006, 38 (08) : 537 - 543
  • [5] Magnetic Resonance Imaging of Perianal Fistulas
    Vanbeckevoort, Dirk
    Bielen, Didier
    Vanslembrouck, Ragna
    Van Assche, Gert
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2014, 22 (01) : 113 - +
  • [6] Role of magnetic resonance imaging in the assessment of perianal fistulas
    Al-Khawari, HA
    Gupta, R
    Sinan, TS
    Prakash, B
    Al-Amer, A
    Al-Bolushi, S
    MEDICAL PRINCIPLES AND PRACTICE, 2005, 14 (01) : 46 - 52
  • [7] Prospective comparison of hydrogen peroxide-enhanced three-dimensional endoanal ultrasonography and endoanal magnetic resonance imaging of perianal fistulas
    West, RL
    Zimmerman, DDE
    Dwarkasing, S
    Hussain, SM
    Hop, WCJ
    Schouten, WR
    Kuipers, EJ
    Felt-Bersma, RJF
    DISEASES OF THE COLON & RECTUM, 2003, 46 (10) : 1407 - 1415
  • [8] Structured magnetic resonance imaging and endoanal ultrasound anal fistulas reporting template (SMART): An interdisciplinary Delphi consensus
    Sudol-Szopinska, Iwona
    Garg, Pankaj
    Mellgren, Anders
    Spinelli, Antonino
    Breukink, Stephanie
    Iacobellis, Francesca
    Kolodziejczak, Malgorzata
    Ciesielski, Przemyslaw
    Jenssen, Christian
    Santoro, Giulio Aniello
    WORLD JOURNAL OF GASTROINTESTINAL SURGERY, 2024, 16 (10):
  • [9] Endoanal ultrasound in the pre-operative assessment of anal fistulas
    Benjelloun, E. B.
    El Abkari, M.
    Souiki, T.
    Ibrahimi, A.
    Taleb, K. Ait
    ACTA ENDOSCOPICA, 2013, 43 (03) : 69 - 72
  • [10] A Diagnostic Accuracy Meta-analysis of Endoanal Ultrasound and MRI for Perianal Fistula Assessment
    Siddiqui, Muhammed R. S.
    Ashrafian, Hutan
    Tozer, Phil
    Daulatzai, Najib
    Burling, David
    Hart, Ailsa
    Athanasiou, Thanos
    Phillips, Robin K.
    DISEASES OF THE COLON & RECTUM, 2012, 55 (05) : 576 - 585