Reliability evaluation of DC power optimizers for photovoltaic systems: Accelerated testing at high temperatures with fixed and cyclic power stresses

被引:6
作者
Afridi, Muhammad [1 ]
Tatapudi, Sai [1 ]
Flicker, Jack [2 ]
Srinivasan, Devarajan [3 ]
Tamizhmani, Govindasamy [1 ]
机构
[1] Arizona State Univ, Photovolta Reliabil Lab, Mesa, AZ 85212 USA
[2] Sandia Natl Labs, Albuquerque, NM 87105 USA
[3] Poundra LLC, Tempe, AZ 85281 USA
关键词
Accelerated life test (ALT); Module -level power electronics (MLPE); DC optimizer; Photovoltaic (PV) systems; Weibull distribution model; Reliability; ELECTRONICS; BEHAVIOR; MODULES; IGBT;
D O I
10.1016/j.engfailanal.2023.107484
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper presents a long-term and large-scale time-to-failure reliability study to determine the acceleration factor and field-use lifetime for dc optimizers. Forty optimizers were tested at two high static temperatures (85 degrees C and 95 degrees C) and two input power profiles (fixed power and cyclic power) over a period of 6400 h. For degradation analysis, continuous electrical and thermal data were collected. On average, the dc optimizer units degraded by about 1%, while no hard failures occurred over 6400 h of high-temperature stress testing. Using the Arrhenius life-stress model along with average field measured temperature, it is predicted that the dc optimizers should be able to survive for 39-73 years in field operating conditions with a reliability of 79%, having a lower one-sided confidence bound of 90%, demonstrating similar or even exceeding the lifetime of the associated PV modules. Nevertheless, with the determined activation energy of 0.33 eV, derived from the observed degradation percentage in cyclic power profiles, the projected lifespan for dc optimizers is significantly curtailed. Under field conditions, our estimations suggest a service life ranging between 9 and 12 years. Furthermore, the cyclic power profile at higher stress temperature demonstrated higher levels of degradation compared to the fixed power profile. This implies the cyclic thermal mechanisms at higher stress temperature (which are not captured in the Arrhenius equation) account for a higher contribution to degradation. This has been confirmed through the use of Weibull distribution model where the analysis indicates that the estimated lifetime for dc optimizer can significantly decrease based on a higher stress temperature along with the power cycling of the units.
引用
收藏
页数:13
相关论文
共 45 条
[1]   Energy efficiency effective design of DC/DC converters for DMPPT PV applications [J].
Adinolfi, G. ;
Femia, N. ;
Petrone, G. ;
Spagnuolo, G. ;
Vitelli, M. .
IECON: 2009 35TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS, VOLS 1-6, 2009, :4341-+
[2]  
Afridi M.A., 2017, International Journal of Engineering Works, V4, P143
[3]   Hotspot testing of glass/backsheet and glass/glass PV modules pre-stressed in extended thermal cycling [J].
Afridi, Muhammad ;
Kumar, Akash ;
Mahmood, Farrukh Ibne ;
Tamizhmani, Govindasamy .
SOLAR ENERGY, 2023, 249 :467-475
[4]  
[Anonymous], 2015, Photovoltaic Systems with Module-Level Power Electronics
[5]  
[Anonymous], 2021, IEC 62093-2021
[6]   A DISCUSSION ON THE TEMPERATURE-DEPENDENCE OF LATCH-UP TRIGGER CURRENT IN CMOS/BICMOS STRUCTURES [J].
AOKI, T .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1993, 40 (11) :2023-2028
[7]  
Armijo Kenneth M., 2015, 2015 IEEE 42nd Photovoltaic Specialist Conference (PVSC). Proceedings, P1, DOI 10.1109/PVSC.2015.7355989
[8]  
Bilal M., 2016, International Journal of Engineering Works, V3, P98
[9]   Turn-Off Time as an Early Indicator of Insulated Gate Bipolar Transistor Latch-up [J].
Brown, Douglas W. ;
Abbas, Manzar ;
Ginart, Antonio ;
Ali, Irfan N. ;
Kalgren, Patrick W. ;
Vachtsevanos, George J. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (02) :479-489
[10]   A DISCUSSION ON IGBT SHORT-CIRCUIT BEHAVIOR AND FAULT PROTECTION SCHEMES [J].
CHOKHAWALA, RS ;
CATT, J ;
KIRALY, L .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1995, 31 (02) :256-263