Effect of the Coil Excitation Method on the Performance of a Dual-Coil Inductive Displacement Transducer

被引:2
|
作者
Xu, Jikang [1 ,2 ]
Li, Yanchao [1 ]
Li, Ruichuan [1 ,2 ]
Yang, Junru [1 ]
Yu, Xiaodong [1 ]
机构
[1] Shandong Univ Sci & Technol, Coll Mech & Elect Engn, Qingdao 266590, Peoples R China
[2] Shandong Univ Sci & Technol, Coll Transportat, Qingdao 266590, Peoples R China
关键词
dual-coil inductive displacement transducer; conditioning circuit; coil excitation method; linearity; sensitivity; DESIGN; SENSOR; FIELD;
D O I
10.3390/s23073703
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A dual-coil inductive displacement transducer is a non-contact type measuring element for measuring displacement and is widely used in large power equipment systems such as construction machinery and agricultural equipment. However, the effect of the coil excitation method on the performance of dual-coil inductive displacement sensors has not been studied. This paper investigates the impact of different coil excitation methods on the operating performance of displacement transducers. The working principle, electromagnetic characteristics, and electrical characteristics were analyzed by building a mathematical model. A transducer measurement device was used to determine the relationship between core displacement and coil inductance. Three coil excitation methods were proposed, and the effects of the three coil excitation methods on the amplitude variation, phase shift, linearity, and sensitivity of the output signal were studied by simulation based on the AD630 chip as the core of the conditioning circuit. Finally, the study's feasibility was demonstrated by comparing the experiment to the simulation. The results show that, under the uniform magnetic field strength distribution in the coil, the coil voltage variation is proportional to the inductive core displacement. The amplitude variation is the largest for the dual-coil series three-wire (DCSTW) and is the same for the dual-coil series four-wire (DCSFW) and dual-coil parallel differential (DCPD). DCSFW has an enormous phase shift. DCSTW has the best linearity. The research in this paper provides a theoretical basis for selecting a suitable coil excitation, which is conducive to further improving the operating performance of dual-coil inductive displacement transducers.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Effect of Excitation Signal on Double-Coil Inductive Displacement Transducer
    Li, Yanchao
    Li, Ruichuan
    Yang, Junru
    Xu, Jikang
    Yu, Xiaodong
    SENSORS, 2023, 23 (07)
  • [2] The Effect of Frequency on Double-Coil Inductive Displacement Transducer
    Li, Yanchao
    Li, Ruichuan
    Yang, Junru
    Xu, Jikang
    Yu, Xiaodong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 15
  • [3] Effect of Inductive Coil Shape on Sensing Performance of Linear Displacement Sensor Using Thin Inductive Coil and Pattern Guide
    Misron, Norhisam
    Ying, Loo Qian
    Firdaus, Raja Nor
    Abdullah, Norrimah
    Mailah, Nashiren Farzilah
    Wakiwaka, Hiroyuki
    SENSORS, 2011, 11 (11) : 10522 - 10533
  • [4] A study of the effect of different coplanar dual-coil geometries on the performance of mutual inductance
    Liao, Siansyun
    Li, Weichen
    Lin, Shihwei
    Tang, Kenwei
    Liou, Chengshiun
    Tsou, Chingfu
    SENSORS AND ACTUATORS A-PHYSICAL, 2018, 269 : 99 - 110
  • [5] Are Dual-Coil ICD Leads Obsolete?
    Barold, S. Serge
    Herweg, Bengt
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2013, 36 (08): : 923 - 925
  • [6] SHADING COIL DISPLACEMENT TRANSDUCER
    MILLER, RH
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS AND CONTROL INSTRUMENTATION, 1970, IE17 (02): : 188 - &
  • [7] A Dual-Coil Method for Electromagnetic Attraction Forming of Sheet Metals
    Xiong, Qi
    Yang, Meng
    Liu, Xin
    Song, Xianqi
    Qiu, Li
    Jiang, Jinbo
    Yu, Kun
    IEEE ACCESS, 2020, 8 : 92708 - 92717
  • [8] FIBEROPTIC DUAL-COIL SENSOR FOR SIMULTANEOUS MEASUREMENTS OF MECHANICAL DISPLACEMENT AND TEMPERATURE-CHANGE
    OKA, K
    TAKEDA, T
    OHTSUKA, Y
    SENSORS AND ACTUATORS A-PHYSICAL, 1990, 22 (1-3) : 438 - 441
  • [9] AutoCapture with dual-coil leads of implantable cardioverter defibrillator
    Acosta, H
    Massumi, A
    Malik, R
    Ahmad, S
    Antonio, C
    Syed, ZA
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 : S267 - S269
  • [10] Regression analysis for deflection magnetic field parameters measured by the dual-coil method
    Sun, Ke-chen
    Li, Guo-feng
    Feng, Yuan-ming
    Wang, Jin
    Liang, Ke
    OPTIK, 2011, 122 (10): : 896 - 899