Retinex-qDPC: Automatic background-rectified quantitative differential phase contrast imaging

被引:3
作者
Zhang, Shuhe [1 ,2 ]
Peng, Tao [1 ]
Ke, Zeyu [1 ]
Yang, Han [1 ]
Berendschot, Tos T. J. M. [2 ]
Zhou, Jinhua [1 ,3 ]
机构
[1] Anhui Med Univ, Sch Biomed Engn, Hefei 230032, Peoples R China
[2] Maastricht Univ, Univ Eye Clin Maastricht, Med Ctr, POB 5800, NL-6202 AZ Maastricht, Netherlands
[3] Anhui Med Univ, Anhui Prov Inst Translat Med, Hefei 230032, Peoples R China
关键词
Retinex theory; Quantitative phase retrieval; Differential phase contrast imaging; Background correction; Deconvolution; CODED LED MICROSCOPY; HIGH-RESOLUTION; REMOVAL; MODEL;
D O I
10.1016/j.cmpb.2022.107327
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: The quality of quantitative differential phase contrast reconstruction (qDPC) can be severely degenerated by the mismatch of the background of two oblique illuminated images, yield-ing problematic phase recovery results. These background mismatches may result from illumination pat-terns, inhomogeneous media distribution, or other defocusing layers. In previous reports, the background is manually calibrated which is time-consuming, and unstable, since new calibrations are needed if any modification to the optical system was made. It is also impossible to calibrate the background from the defocusing layers, or for high dynamic observation as the background changes over time. The background mismatch reduces the experimental robustness of qDPC and largely limits its applications. To tackle the mismatch of background and increases the experimental robustness, we propose the Retinex-qDPC.Methods: In Retinex-qDPC, we replace the data fidelity term of the previous cost function for qDPC inverse problem, by the images' edge features yielding L2-Retinex-qDPC and L1-Retinex-qDPC for high background-robustness qDPC reconstruction. The split Bregman method is used to solve the L1-Retinex DPC. We compare both Retinex-qDPC models against state-of-the-art DPC reconstruction algorithms in-cluding total-variation regularized qDPC, and isotropic-qDPC using both simulated and experimental data.Results: Retinex qDPC can significantly improve the phase recovery quality by suppressing the impact of mismatch background. Within, the L1-Retinex-qDPC is better than L2-Retinex and other state-of-the-art qDPC algorithms.Conclusions: The Retinex-qDPC increases the experimental robustness against background illumination without any modification of the optical system, which will benefit all qDPC applications.(c) 2022 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)
引用
收藏
页数:12
相关论文
共 38 条
  • [11] Guang Z., 2020, SPIE
  • [12] DIFFERENTIAL PHASE-CONTRAST IN SCANNING OPTICAL MICROSCOPY
    HAMILTON, DK
    SHEPPARD, CJR
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1984, 133 (JAN): : 27 - 39
  • [13] Adaptive background interference removal for Fourier ptychographic microscopy
    Hou, Lexin
    Wang, Hexin
    Sticker, Markus
    Stoppe, Lars
    Wang, Junhua
    Xu, Min
    [J]. APPLIED OPTICS, 2018, 57 (07) : 1575 - 1580
  • [14] Single-shot phase contrast microscopy using polarisation-resolved differential phase contrast
    Kalita, Ranjan
    Flanagan, William
    Lightley, Jonathan
    Kumar, Sunil
    Alexandrov, Yuriy
    Garcia, Edwin
    Hintze, Mark
    Barkoulas, Michalis
    Dunsby, Chris
    French, Paul M. W.
    [J]. JOURNAL OF BIOPHOTONICS, 2021, 14 (12)
  • [15] A variational framework for Retinex
    Kimmel, R
    Elad, M
    Shaked, D
    Keshet, R
    Sobel, I
    [J]. INTERNATIONAL JOURNAL OF COMPUTER VISION, 2003, 52 (01) : 7 - 23
  • [16] Transscleral optical phase imaging of the human retina
    Laforest, Timothe
    Kuenzi, Mathieu
    Kowalczuk, Laura
    Carpentras, Dino
    Behar-Cohen, Francine
    Moser, Christophe
    [J]. NATURE PHOTONICS, 2020, 14 (07) : 439 - +
  • [17] Color-coded LED microscopy for multi-contrast and quantitative phase-gradient imaging
    Lee, Donghak
    Ryu, Suho
    Kim, Uihan
    Jung, Daeseong
    Joo, Chulmin
    [J]. BIOMEDICAL OPTICS EXPRESS, 2015, 6 (12): : 4912 - 4922
  • [18] Color-coded LED microscopy for quantitative phase imaging: Implementation and application to sperm motility analysis
    Lee, Wonchan
    Choi, Jun-Ho
    Ryu, Suho
    Jung, Daeseong
    Song, Jaewoo
    Lee, Jong-Seok
    Joo, Chulmin
    [J]. METHODS, 2018, 136 : 66 - 74
  • [19] Single-exposure quantitative phase imaging in color-coded LED microscopy
    Lee, Wonchan
    Jung, Daeseong
    Ryu, Suho
    Joo, Chulmin
    [J]. OPTICS EXPRESS, 2017, 25 (07): : 8398 - 8411
  • [20] Quantitative differential phase contrast imaging at high resolution with radially asymmetric illumination
    Lin, Yu-Zi
    Huang, Kuang-Yuh
    Luo, Yuan
    [J]. OPTICS LETTERS, 2018, 43 (12) : 2973 - 2976