Carbon nanofiber-based voltammetric sensor for the simultaneous quantification of β-Lactum antibiotics as amoxicillin and clavunate potassium

被引:4
作者
Sharma, Swati [1 ]
Jain, Rajeev [2 ]
Pandey, Annu [3 ]
机构
[1] Jiwaji Univ, Sch Studies Environm Chem, Gwalior 474011, India
[2] Pondicherry Univ, Kalapet 605014, India
[3] Chandigarh Univ, Dept Chem, Mohali 140413, Punjab, India
关键词
Carbon nanofiber; Amoxicillin; Clavunate potassium; Glassy carbon electrode; Voltammetry; CLAVULANIC ACID; ELECTROCHEMICAL DETECTION; DIHYDROXYBENZENE ISOMERS; NANOTUBES; CATECHOL; ELECTRODE; HYDROQUINONE; PERFORMANCE; COMPOSITES;
D O I
10.1016/j.materresbull.2023.112295
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The present work reports a novel electrochemical method for the simultaneous quantification of amoxicillin (AMX) and clavunate potassium (CLV) at carbon nanofiber-modified glassy carbon electrode (GCE) by using square wave voltammetry due to its high sensitivity, low cost, simplicity, and degrades the signal-to-noise ratio. The developed sensor was characterized by Scanning electron microscopy, Transmission electron microscopy, X -Ray powder diffraction, Infrared spectroscopy, electrochemical impedance spectroscopy, and cyclic voltamme-try. The fabricated electrode exhibited excellent electrocatalytic activity towards electrochemical oxidation of both compounds in BR buffer pH 2.0. All the instrumental parameter that affects the anodic peak current of AMX and CLV was also optimized during the investigation. Two well-resolved oxidation peaks at 0.55 V and 1.05 V for AMX and CLV were optimized at the time of analysis of these analytes. The limit of detection was 98 nM for AMX and 95 nM for CLV and the limit of quantification was 0.298 mu M and 0.289 mu M for AMX and CLV respectively, achieved at the fabricated sensor. The proposed method has also been examined in pharmaceutical formulation and biological samples with satisfactory recovery results.
引用
收藏
页数:8
相关论文
共 45 条
[1]   SPECTROPHOTOMETRIC DETERMINATION OF AMOXYCILLIN AND CLAVULANIC ACID IN PHARMACEUTICAL PREPARATIONS [J].
ABDELMOETY, EM ;
ABOUNASSIF, MA ;
MOHAMED, ME ;
KHATTAB, NA .
TALANTA, 1989, 36 (06) :683-685
[2]   LIQUID-CHROMATOGRAPHIC DETERMINATION OF AMOXICILLIN AND CLAVULANIC ACID IN PHARMACEUTICAL PREPARATIONS [J].
ABOUNASSIF, MA ;
ABDELMOETY, EM ;
MOHAMED, ME ;
GADKARIEM, EA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1991, 9 (09) :731-735
[3]   Performance of electrodes synthesized with polyacrylonitrile-based carbon nanofibers for application in electrochemical sensors and biosensors [J].
Adabi, Mandi ;
Saber, Reza ;
Faridi-Majidi, Reza ;
Faridbod, Farnoush .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 48 :673-678
[4]   Electrospun carbon nanofiber-carbon nanotubes coated polyaniline composites with improved electrochemical properties for supercapacitors [J].
Agyemang, Frank Ofori ;
Tomboc, Gracita M. ;
Kwofie, Samuel ;
Kim, Hern .
ELECTROCHIMICA ACTA, 2018, 259 :1110-1119
[5]   Exploring the electrocatalytic sites of carbon nanotubes for NADH detection: an edge plane pyrolytic graphite electrode study [J].
Banks, CE ;
Compton, RG .
ANALYST, 2005, 130 (09) :1232-1239
[6]   CHEMICAL MODIFICATION OF ELECTRODES [J].
BARD, AJ .
JOURNAL OF CHEMICAL EDUCATION, 1983, 60 (04) :302-304
[7]   Evaluation of different voltammetric techniques in the determination of amoxicillin using a carbon paste electrode modified with [N,N′-ethylenebis(salicylideneaminato)] oxovanadium(IV) [J].
Bergamini, MF ;
Teixeira, MFS ;
Dockal, ER ;
Bocchi, N ;
Cavalheiro, ETG .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2006, 153 (05) :E94-E98
[8]   An enhanced electrochemical platform based on graphene-polyoxometalate nanomaterials for sensitive determination of diphenolic compounds [J].
Cao, Linyuan ;
Sun, Hongmei ;
Li, Jing ;
Lu, Lehui .
ANALYTICAL METHODS, 2011, 3 (07) :1587-1594
[9]   Direct simultaneous determination of dihydroxybenzene isomers at C-nanotube-modified electrodes by derivative voltammetry [J].
Ding, YP ;
Liu, WL ;
Wu, QS ;
Wang, XG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 575 (02) :275-280
[10]   A voltammetric sensor based on graphene-modified electrode for simultaneous determination of catechol and hydroquinone [J].
Du, Haijun ;
Ye, Jianshan ;
Zhang, Jiaqi ;
Huang, Xiaodan ;
Yu, Chengzhong .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 650 (02) :209-213