Left bundle area pacing: Guiding implant depth by ring measurements

被引:3
作者
Orlov, Michael, V [1 ,2 ]
Nikolaychuk, Marianna [1 ]
Koulouridis, Ioannis [1 ]
Goldman, Alena [1 ]
Natan, Shaw [1 ]
Armstrong, James [1 ]
Bhattacharya, Adhiraj [1 ]
Hicks, Amy [1 ]
King, Michael [1 ]
Wylie, John [1 ]
机构
[1] Tufts Univ, Steward St Elizabeths Med Ctr, Sch Med, Dept Med,Div Cardiol,Sect Electrophysiol, Boston, MA USA
[2] Steward St Elizabeths Med Ctr, 736 Cambridge St, Boston, MA 02135 USA
关键词
Depth of lead implantation; Lead-septal angle; Left bundle area pacing; Unipolar ring impedance; Unipolar ring measurements; Unipolar ring pacing threshold; CARDIAC RESYNCHRONIZATION THERAPY;
D O I
10.1016/j.hrthm.2022.09.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Criteria for successful left bundle area pacing (LBAP) are in flux and currently guided by lead tip measurements. Lead ring measurements during LBAP have not been well studied. OBJECTIVE The purpose of this study was to investigate dynamics in pacing parameters during successful and unsuccessful lead implant attempts.METHODS SelectSecure 3830 pacing leads (Medtronic, Inc) guided by C315 sheaths for LBAP were placed for standard pacing indications in 73 patients. Retrospective review of procedural, echocardiographic, and standard pacing data were performed. Depth and lead-septal angle of implanted electrodes were determined from fluoroscopy with septal contrast delineation. Depth was graded in 4 categories according to the degree of ring penetration into the septum. Successful implant was defined by the ability to advance the lead deep into the septum and achieve LBAP criteria (ventricular activation time, QRS width/shape).RESULTS Ring impedance increased stepwise during successful attempts as opposed to unsuccessful attempts (P = .039). A wider lead-septal angle at implant position correlated with higher ring impedance (P = .036), whereas no association was found with tip impedance. Unipolar ring threshold correlated with depth of lead implant (P = .029). Tip impedance measurements at implant position were less predictive of lead depth and did not correlate with septal thickness.CONCLUSION Ring pacing parameters are more predictive of lead progress than tip measurements. Lead depth and lead-septal angle can be determined from ring impedance measurements. These measurements may provide determination of lead depth and could obviate the need for contrast injection.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 20 条
[1]   The Atrioventricular Conduction Axis and its Implications for Permanent Pacing [J].
Cabrera, Jose-Angel ;
Anderson, Robert H. ;
Porta-Sanchez, Andreu ;
Macias, Yolanda ;
Cano, Oscar ;
Spicer, Diane E. ;
Sanchez-Quintana, Damian .
ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2021, 10 (03) :181-189
[2]   Procedure-Related Complications of Left Bundle Branch Pacing: A Single-Center Experience [J].
Chen, Xueying ;
Wei, Lanfang ;
Bai, Jin ;
Wang, Wei ;
Qin, Shengmei ;
Wang, Jingfeng ;
Liang, Yixiu ;
Su, Yangang ;
Ge, Junbo .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
[3]   Left Ventricular Myocardial Septal Pacing in Close Proximity to LBB Does Not Prolong the Duration of the Left Ventricular Lateral Wall Depolarization Compared to LBB Pacing [J].
Curila, Karol ;
Jurak, Pavel ;
Vernooy, Kevin ;
Jastrzebski, Marek ;
Waldauf, Petr ;
Prinzen, Frits ;
Halamek, Josef ;
Susankova, Marketa ;
Znojilova, Lucie ;
Smisek, Radovan ;
Karch, Jakub ;
Plesinger, Filip ;
Moskal, Pawel ;
Heckman, Luuk ;
Mizner, Jan ;
Viscor, Ivo ;
Vondra, Vlastimil ;
Leinveber, Pavel ;
Osmancik, Pavel .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
[4]   A Guide to Left Bundle Branch Area Pacing Using Stylet-Driven Pacing Leads [J].
De Pooter, Jan ;
Wauters, Aurelien ;
Van Heuverswyn, Frederic ;
Le Polain de Waroux, Jean-Benoit .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
[5]   Left bundle branch area pacing using stylet-driven pacing leads with a new delivery sheath: A comparison with lumen-less leads [J].
De Pooter, Jan ;
Calle, Simon ;
Timmermans, Frank ;
Van Heuverswyn, Frederic .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (02) :439-448
[6]   Feasibility and safety of left bundle branch area pacing-cardiac resynchronization therapy in elderly patients [J].
Grieco, Domenico ;
Bressi, Edoardo ;
Sedlacek, Kamil ;
Curila, Karol ;
Vernooy, Kevin ;
Fedele, Elisa ;
De Ruvo, Ermenegildo ;
Fagagnini, Alessandro ;
Kron, Jordana ;
Padala, Santosh K. ;
Ellenbogen, Kenneth A. ;
Calo, Leonardo .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (02) :311-321
[7]   Comparing Ventricular Synchrony in Left Bundle Branch and Left Ventricular Septal Pacing in Pacemaker Patients [J].
Heckman, Luuk I. B. ;
Luermans, Justin G. L. M. ;
Curila, Karol ;
Van Stipdonk, Antonius M. W. ;
Westra, Sjoerd ;
Smisek, Radovan ;
Prinzen, Frits W. ;
Vernooy, Kevin .
JOURNAL OF CLINICAL MEDICINE, 2021, 10 (04) :1-13
[8]   Cardiac Resynchronization Therapy in Patients With Nonischemic Cardiomyopathy Using Left Bundle Branch Pacing [J].
Huang, Weijian ;
Wu, Shengjie ;
Vijayaraman, Pugazhendhi ;
Su, Lan ;
Chen, Xueying ;
Cai, Bingni ;
Zou, Jiangang ;
Lan, Rongfang ;
Fu, Guosheng ;
Mao, Guangyun ;
Ellenbogen, Kenneth A. ;
Whinnett, Zachary, I ;
Tung, Roderick .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2020, 6 (07) :849-858
[9]   A beginner's guide to permanent left bundle branch pacing [J].
Huang, Weijian ;
Chen, Xueying ;
Su, Lan ;
Wu, Shengjie ;
Xia, Xue ;
Vijayaraman, Pugazhendhi .
HEART RHYTHM, 2019, 16 (12) :1791-1796
[10]   Fixation beats: A novel marker for reaching the left bundle branch area during deep septal lead implantation [J].
Jastrzebski, Marek ;
Kiebasa, Grzegorz ;
Moskal, Pawe ;
Bednarek, Agnieszka ;
Kusiak, Aleksander ;
Sondej, Tomasz ;
Bednarski, Adam ;
Rajzer, Marek ;
Vijayaraman, Pugazhendhi .
HEART RHYTHM, 2021, 18 (04) :562-569