Concurrent Validity of Four Activity Monitors in Older Adults

被引:3
作者
Wullems, Jorgen A. [1 ]
Verschueren, Sabine M. P. [2 ]
Degens, Hans [3 ,4 ]
Morse, Christopher I. [1 ]
Onambele-Pearson, Gladys L. [1 ]
机构
[1] Manchester Metropolitan Univ, Inst Sport, Fac Sci & Engn, Dept Sport & Exercise Sci, Manchester M1 7EL, England
[2] Katholieke Univ Leuven, Dept Rehabil Sci, Musculoskeletal Rehabil Res Grp, B-3001 Leuven, Belgium
[3] Manchester Metropolitan Univ, Inst Sport, Fac Sci & Engn, Dept Life Sci, Manchester M1 5GD, England
[4] Lithuanian Sports Univ, Inst Sport Sci & Innovat, LT-44221 Kaunas, Lithuania
关键词
ageing; accelerometry; physical behaviour; PHYSICAL-ACTIVITY; SEDENTARY BEHAVIOR; WORN ACCELEROMETERS; ENERGY-EXPENDITURE; ALGORITHMS; POSTURE; AGE; PERFORMANCE; ACCURACY; HIP;
D O I
10.3390/s24030895
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sedentary behaviour (SB) and physical activity (PA) have been shown to be independent modulators of healthy ageing. We thus investigated the impact of activity monitor placement on the accuracy of detecting SB and PA in older adults, as well as a novel random forest algorithm trained on data from older persons. Four monitor types (ActiGraph wGT3X-BT, ActivPAL3c VT, GENEActiv Original, and DynaPort MM+) were simultaneously worn on five anatomical sites during ten different activities by a sample of twenty older adults (70.0 (12.0) years; 10 women). The results indicated that collecting metabolic equivalent (MET) data for 60 s provided the most representative results, minimising variability. In addition, thigh-worn monitors, including ActivPAL, Random Forest, and Sedentary Sphere-Thigh, exhibited superior performance in classifying SB, with balanced accuracies >= 94.2%. Other monitors, such as ActiGraph, DynaPort MM+, and GENEActiv Sedentary Sphere-Wrist, demonstrated lower performance. ActivPAL and GENEActiv Random Forest outperformed other monitors in participant-specific balanced accuracies for SB classification. Only thigh-worn monitors achieved acceptable overall balanced accuracies (>= 80.0%) for SB, standing, and medium-to-vigorous PA classifications. In conclusion, it is advisable to position accelerometers on the thigh, collect MET data for >= 60 s, and ideally utilise population-specific trained algorithms.
引用
收藏
页数:16
相关论文
共 44 条
[1]   Validity of self-report methods for measuring sedentary behaviour in older adults [J].
Aguilar-Farias, Nicolas ;
Brown, Wendy J. ;
Olds, Timothy S. ;
Peeters, G. M. E. E. .
JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2015, 18 (06) :662-666
[2]  
Amri M.M., 2023, Mesopotamian Journal of Big Data, V2023, P68, DOI DOI 10.58496/MJBD/2023/010
[3]   Physical Activity and Health of Middle-Aged and Older Japanese Across the COVID-19 Pandemic: Differential Outcomes Highlight a Problematic Life Stage [J].
Annear, Michael ;
Kidokoro, Tetsuhiro ;
Shimizu, Yasuo .
JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2024, 32 (02) :264-275
[4]   Validation of the Activ8 Activity Monitor for Monitoring Postures, Motions, Transfers, and Steps of Hospitalized Patients [J].
Becker, Marlissa L. ;
Hurkmans, Henri L. P. ;
Verhaar, Jan A. N. ;
Bussmann, Johannes B. J. .
SENSORS, 2024, 24 (01)
[5]   Day-to-day variability in accelerometer-measured physical activity in mid-aged Australian adults [J].
Brady, Ruth ;
Brown, Wendy J. ;
Mielke, Gregore I. .
BMC PUBLIC HEALTH, 2023, 23 (01)
[6]   Metabolic equivalent: one size does not fit all [J].
Byrne, NM ;
Hills, AP ;
Hunter, GR ;
Weinsier, RL ;
Schutz, Y .
JOURNAL OF APPLIED PHYSIOLOGY, 2005, 99 (03) :1112-1119
[7]   Validation of the AX3 triaxial accelerometer in older functionally impaired people [J].
Clarke, Clare L. ;
Taylor, Judith ;
Crighton, Linda J. ;
Goodbrand, James A. ;
McMurdo, Marion E. T. ;
Witham, Miles D. .
AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2017, 29 (03) :451-457
[8]   A novel method for using accelerometer data to predict energy expenditure [J].
Crouter, SE ;
Clowers, KG ;
Bassett, DR .
JOURNAL OF APPLIED PHYSIOLOGY, 2006, 100 (04) :1324-1331
[9]   Can measured resting energy expenditure be estimated by formulae in daily clinical nutrition practice? [J].
da Rocha, EEM ;
Alves, VGF ;
Silva, MHN ;
Chiesa, CA ;
da Fonseca, RBV .
CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2005, 8 (03) :319-328
[10]   Accuracy of Posture Allocation Algorithms for Thigh- and Waist-Worn Accelerometers [J].
Edwardson, Charlotte L. ;
Rowlands, Alex V. ;
Bunnewell, Sarah ;
Sanders, James ;
Esliger, Dale W. ;
Gorely, Trish ;
O'Connell, Sophie ;
Davies, Melanie J. ;
Khunti, Kamlesh ;
Yates, Thomas .
MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2016, 48 (06) :1085-1090