Transient Behavior Analysis of the Infiltration Heat Recovery of Exterior Building Walls

被引:3
作者
Alaidroos, Alaa [1 ]
机构
[1] King Abdulaziz Univ, Fac Engn, Architectural Engn Dept, Rabigh Branch, Jeddah 21589, Saudi Arabia
关键词
infiltration heat recovery; building thermal mass; wall's heat capacity; numerical modeling; breathing wall; FLOW;
D O I
10.3390/en16207198
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This research study investigated the transient behavior of the convection-diffusion model for the infiltration heat recovery (IHR) and the influence of the building envelope heat capacity, along with other factors. A transient numerical model was developed and validated to analyze the IHR under various conditions. The results highlight the role of heat capacity, thermal conductivity, wall thickness, airflow rate, airflow direction, and wall porosity on the temperature distribution and the heat recovery factor within the wall. Higher-heat-capacity walls displayed a delayed temperature rise, while low-thermal-conductivity walls reduced the conduction heat transfer and increased the IHR factor. The impact of heat capacity diminished with very low thermal conductivity walls but became evident for high-thermal-conductivity walls, particularly at higher Peclet numbers. Thicker walls enhanced the heat retention and improved the IHR, with a reduced influence of airflow rate. Higher IHR factors were associated with thicker walls, lower Peclet numbers, and higher heat capacities. The analysis also showed that the wall porosity affected the IHR with less significance than the other factors. Incorporating these findings into building energy modeling tools could improve the prediction accuracy of the thermal behavior of buildings. Accordingly, this study contributes to building physics by understanding IHR dynamics and thermal mass interactions, as well as improving building energy modeling accuracy for performance prediction. Future research can explore the impacts of additional factors on IHR and investigate the effect of IHR on the overall energy consumption of buildings.
引用
收藏
页数:21
相关论文
共 27 条
[11]  
Bhattacharyya S., 1995, J. Sol. Energy Eng. Trans. ASME, V112, P132
[12]   Measurement of infiltration heat recovery in a test cell with high flow rates [J].
Brownell, Cody J. .
JOURNAL OF BUILDING PHYSICS, 2015, 38 (04) :350-359
[13]  
Buchanan C.R., 2000, A Mathematical Model for Infiltration Heat Recovery
[14]   Dynamic insulation systems of building envelopes: A review [J].
Fawaier, Mohammad ;
Bokor, Balazs .
ENERGY AND BUILDINGS, 2022, 270
[15]  
Janssens A, 2003, RESEARCH IN BUILDING PHYSICS, P759
[16]   Experimental study on the deterioration of thermal insulation performance due to wind washing of the cavity insulation in leaky walls [J].
Kosinski, Piotr ;
Wojcik, Robert ;
Semen, Beata .
SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (09) :1164-1177
[17]   EFFECT OF AIR-FLOW ON HEAT-TRANSFER IN WALLS [J].
KRARTI, M .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (01) :35-42
[18]  
Liu Mingsheng., 1992, Study of air infiltration energy consumption
[19]   Modeling the combined conduction - Air infiltration through diffusive building envelope [J].
Qiu, Kai ;
Haghighat, Fariborz .
ENERGY AND BUILDINGS, 2007, 39 (11) :1140-1150
[20]  
Sherman M.H., 2003, Project# LBNL 53484