Effect of Fireproof Coatings on the Post-Fire Behavior of CFRP Composite Sheets

被引:6
作者
Qiang, Xuhong [1 ]
Wang, Kaihao [1 ]
Jiang, Xu [1 ]
Xiao, Yi [2 ]
Yibo, E. [2 ]
机构
[1] Tongji Univ, Coll Civil Engn, Shanghai 200092, Peoples R China
[2] Shanghai Univ, Res Ctr Composite Mat, Sci & Engn Composite Mat, Shanghai 201900, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 18期
基金
中国国家自然科学基金;
关键词
fireproof coatings; carbon fiber-reinforced polymer; fire resistance; post-fire flexural properties; large-space fire condition; standard fire condition; GFRP REINFORCING BARS; MECHANICAL-PROPERTIES; TENSILE PERFORMANCE; FLEXURAL BEHAVIOR; SYNTHETIC-FIBERS; CONCRETE SLABS; FRP BARS; FIRE; TEMPERATURE; STRENGTH;
D O I
10.3390/app131810369
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study examines the effect of two self-developed novel fireproof coatings on the fire resistance of carbon fiber-reinforced polymer (CFRP) composite sheets. The post-fire flexural properties were chosen as important indicators of fire resistance. This research involves two distinct fire conditions, the standard fire condition and the large-space fire condition, to simulate general interior fires and large-space fires. The post-fire flexural performance of CFRP sheets coated with two different self-developed fireproof coatings was evaluated through three-point bending tests after fire exposure. The experimental findings demonstrated a significant reduction of up to 80% in the post-fire flexural properties of CFRP sheets without fireproof coatings. However, CFRP sheets coated with fireproof coatings exhibited a substantial enhancement in their post-fire flexural properties. Under the large-space fire condition, the fire-resistance duration of CFRP sheets coated with fireproof coatings of at least 25 mm thickness exceeded 2 h, satisfying the requirements of GB50016-2014 fire-resistance class III (columns), class I (beams), and class I (floor slabs), respectively. Under the standard fire condition, CFRP sheets covered by fireproof coatings of 35 mm thickness exhibited a fire-resistance duration of 0.75 h, meeting the requirements of GB50016-2014 fire-resistance class IV (columns), class IV (beams), and class III (floor slabs), respectively.
引用
收藏
页数:17
相关论文
共 41 条
  • [1] Influence of synthetic fibers on the shear behavior of lightweight concrete beams
    Ababneh, Ayman
    Al-Rousan, Rajai
    Alhassan, Mohammad
    Alqadami, Mohammed
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2017, 20 (11) : 1671 - 1683
  • [2] Influence of polypropylene fibers on the flexural behavior of reinforced concrete slabs with different opening shapes and sizes
    Al-Rousan, Rajai
    [J]. STRUCTURAL CONCRETE, 2017, 18 (06) : 986 - 999
  • [3] Flexural behavior of lightweight concrete beams encompassing various dosages of macro synthetic fibers and steel ratios
    Alhassan, Mohammad
    Al-Rousan, Rajai
    Ababneh, Ayman
    [J]. CASE STUDIES IN CONSTRUCTION MATERIALS, 2017, 7 : 280 - 293
  • [4] [Anonymous], 2003, BS 5950-8: 2003S
  • [5] [Anonymous], 2017, GUIDE DESIGN CONSTRU
  • [6] [Anonymous], 2006, 2002006 CECS
  • [7] [Anonymous], 2018, GB 50016-2014
  • [8] [Anonymous], 2017, ASTM D790 Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
  • [9] [Anonymous], 2021, ISO 834-1
  • [10] The effect of mechanical and thermal properties of FRP bars on their tensile performance under elevated temperatures
    Ashrafi, Harried
    Bazli, Milad
    Najafabadi, Esmaeil Pournamazian
    Oskouei, Asghar Vatani
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2017, 157 : 1001 - 1010