Trace cadmium determination in lake water matrix by flame atomic absorption spectrometry after manganese ferrite magnetic nanoparticles-based dispersive solid phase extraction

被引:1
作者
Karaman, Devrim Nur [1 ]
Serbest, Hakan [2 ]
Kilinc, Yagmur [3 ]
Demirel, Rabia [1 ]
Bakirdere, Sezgin [1 ,4 ,5 ]
机构
[1] Yildiz Tech Univ, Dept Chem, Istanbul, Turkiye
[2] Istanbul Hlth & Technol Univ, Fac Engn & Nat Sci, Dept Chem Engn, Istanbul, Turkiye
[3] Zonguldak Bulent Ecevit Univ, Dept Environm Engn, Zonguldak, Turkiye
[4] Turkish Acad Sci TUBA, Cankaya, Ankara, Turkiye
[5] Yildiz Tech Univ, Dept Chem, TR-34210 Istanbul, Turkiye
关键词
cadmium; dispersive solid phase extraction; flame atomic absorption spectrophotometry; manganese ferrite magnetic nanoparticles; CLOUD POINT EXTRACTION; ONLINE PRECONCENTRATION; AQUEOUS-SOLUTION; METAL-IONS; LEAD; MICROEXTRACTION; ADSORPTION; SEPARATION; ADSORBENT; CHROMIUM;
D O I
10.1002/clen.202200186
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, manganese ferrite magnetic nanoparticles-based dispersive solid phase extraction (MF-MNP-DSPE) was developed for cadmium determination at trace level by flame atomic absorption spectrometry (FAAS). Manganese ferrite-based magnetic nanoparticles were synthesized to be used as solid phase extraction sorbent. All the analytical conditions were optimized by univariate optimization approach to achieve high enrichment factors. Under the optimum conditions, limit of detection (LOD) and quantification (LOQ) values of the developed method were recorded as 1.3 and 4.3 & mu;g L-1, respectively. Approximately 135-fold improvement in the detection power by the MF-MNP-DSPE-FAAS system was recorded over the traditional FAAS system based on LOD comparison. Recovery experiments were performed to test the applicability/accuracy of the developed method with lake water spiked at different concentrations. Percent recovery values were obtained between 87% and 112% by employing the matrix matching calibration strategy and this showed that the developed method is applicable for the determination of cadmium in lake water samples with high accuracy and precision.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Determination of trace amount of cadmium using dispersive liquid-liquid microextraction-slotted quartz tube-flame atomic absorption spectrometry
    Firat, Merve
    Bakirdere, Sezgin
    Findikoglu, Maral Selin
    Kafa, Emine Betul
    Yazici, Elif
    Yolcu, Melda
    Buyukpinar, Cagdas
    Chormey, Dotse Selali
    Sel, Sabriye
    Turak, Fatma
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 129 : 37 - 41
  • [42] Determination of Trace Copper(II) in Food Samples by Flame Atomic Absorption Spectrometry After Cloud Point Extraction
    Xiang Guoqiang
    Wen Shengping
    Jiang Xiuming
    Liu Xing
    He Lijun
    IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION, 2011, 30 (03): : 101 - 107
  • [43] Sensitive determination of cadmium in brown rice and spinach by flame atomic absorption spectrometry with solid-phase extraction
    Akamatsu, Shigeki
    Yoshioka, Naoki
    Mitsuhashi, Takao
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2012, 29 (11): : 1696 - 1700
  • [44] Nano-sized magnetic Ni particles based dispersive solid-phase extraction of trace Cd before the determination by flame atomic absorption spectrometry with slotted quartz tube: a new, accurate, and sensitive quantification method
    Yagci, Ozlem
    Akkaya, Erhan
    Bakirdere, Sezgin
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2020, 192 (09)
  • [45] Preconcentration and determination of cadmium in some samples using solid phase extraction with slotted quartz tube flame atomic absorption spectrometry
    Arslan, Y.
    Trak, D.
    Kenduzler, E.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2017, 49 (04): : 884 - 889
  • [46] Zirconium Nanoparticles Based Vortex Assisted Ligandless Dispersive Solid Phase Extraction for Trace Determination of Lead in Domestic Wastewater using Flame Atomic Absorption Spectrophotometry
    Esma Ay
    Zeynep Tekin
    Nizamettin Özdoğan
    Sezgin Bakırdere
    Bulletin of Environmental Contamination and Toxicology, 2022, 108 : 324 - 330
  • [47] Solid phase extraction of trace cadmium and lead in food samples using modified peanut shell prior to determination by flame atomic absorption spectrometry
    Xiang, Guoqiang
    Huang, Yan
    Luo, Yifan
    MICROCHIMICA ACTA, 2009, 165 (1-2) : 237 - 242
  • [48] Determination of cadmium at trace levels in parsley samples by slotted quartz tube-flame atomic absorption spectrometry after preconcentration with cloud point extraction
    Kasa, Nursu Aylin
    Sel, Sabriye
    Chormey, Dotse Selali
    Balordere, Sezgin
    MEASUREMENT, 2019, 147
  • [49] Determination of trace amounts of palladium by flame atomic absorption spectrometry after ligandless-dispersive liquid-liquid microextraction
    Mohammadi, Sayed Zia
    Afzali, Daryoush
    Taher, Mohammad Ali
    Baghelani, Yar Mohammad
    MICROCHIMICA ACTA, 2010, 168 (1-2) : 123 - 128
  • [50] Displacement Solid Phase Extraction as Preconcentration Method for the Determination of Trace Copper in Water Samples by Electrothermal Atomic Absorption Spectrometry
    Zhao, Liping
    Gong, Qiaojuan
    Sun, Hong
    Yang, Binwu
    Zhu, Yunde
    ATOMIC SPECTROSCOPY, 2010, 31 (06) : 201 - 205