A microfluidic method to investigate platelet mechanotransduction under extensional strain

被引:10
作者
Abidin, Nurul A. Zainal
Timofeeva, Mariia
Szydzik, Crispin [1 ]
Akbaridoust, Farzan
Lav, Chitrarth [2 ,4 ]
Marusic, Ivan
Mitchell, Arnan [1 ]
Hamilton, Justin R.
Ooi, Andrew S. H.
Nesbitt, Warwick S. [3 ]
机构
[1] Monash Univ, Australian Ctr Blood Dis, Cent Clin Sch, Melbourne, Vic, Australia
[2] Univ Melbourne, Dept Mech Engn, Fac Engn & Informat Technol, Melbourne, Vic, Australia
[3] RMIT Univ, Sch Engn, Melbourne, Vic, Australia
[4] Scuderia AlphaTauri F1, Bicester, England
基金
英国医学研究理事会;
关键词
blood platelets; calcium; hemodynamics; mechanotransduction; microfluidic; VON-WILLEBRAND-FACTOR; CELL-FREE LAYER; BLOOD-FLOW; WALL SHEAR; CALCIUM; AGGREGATION; ADHESION; ACTIVATION; MICROTUBULES; DEFORMATION;
D O I
10.1016/j.rpth.2023.100037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Blood platelets have evolved a complex mechanotransduction machinery to rapidly respond to hemodynamic conditions. A variety of microfluidic flow-based approaches have been developed to explore platelet mechanotransduction; however, these experimental models primarily focus on the effects of increased wall shear stress on platelet adhesion events and do not consider the critical effects of extensional strain on platelet activation in free flow. Objectives: We report the development and application of a hyperbolic microfluidic assay that allows for investigation of platelet mechanotransduction under quasihomogenous extensional strain rates in the absence of surface adhesions. Methods: Using a combined computational fluid dynamic and experimental microfluidic approach, we explore 5 extensional strain regimes (geometries) and their effect on platelet calcium signal transduction. Results: We demonstrate that in the absence of canonical adhesion, receptor engagement platelets are highly sensitive to both initial increase and subsequent decrease in extensional strain rates within the range of 747 to 3319/s. Furthermore, we demonstrate that platelets rapidly respond to the rate of change in extensional strain and define a threshold of >= 7.33 x 10(6)/s/m, with an optimal range of 9.21 x 10(7) to 1.32 x 10(8)/s/m. In addition, we demonstrate a key role of both the actin-based cytoskeleton and annular microtubules in the modulation of extensional strain-mediated platelet mechanotransduction. Conclusion: This method opens a window onto a novel platelet signal transduction mechanism and may have potential diagnostic utility in the identification of patients who are prone to thromboembolic complications associated with high-grade arterial stenosis or are on mechanical circulatory support systems, for which the extensional strain rate is a predominant hemodynamic driver.
引用
收藏
页数:14
相关论文
共 52 条
  • [1] An extensional strain sensing mechanosome drives adhesion-independent platelet activation at supraphysiological hemodynamic gradients
    Abidin, Nurul A. Zainal
    Poon, Eric K. W.
    Szydzik, Crispin
    Timofeeva, Mariia
    Akbaridoust, Farzan
    Brazilek, Rose J.
    Lopez, Francisco J. Tovar
    Ma, Xiao
    Lav, Chitrarth
    Marusic, Ivan
    Thompson, Philip E.
    Mitchell, Arnan
    Ooi, Andrew S. H.
    Hamilton, Justin R.
    Nesbitt, Warwick S.
    [J]. BMC BIOLOGY, 2022, 20 (01)
  • [2] Simultaneous micro-PIV measurements and real-time control trapping in a cross-slot channel
    Akbaridoust, Farzan
    Philip, Jimmy
    Hill, David R. A.
    Marusic, Ivan
    [J]. EXPERIMENTS IN FLUIDS, 2018, 59 (12)
  • [3] Correlation of thrombosis growth rate to pathological wall shear rate during platelet accumulation
    Bark, David L., Jr.
    Para, Andrea N.
    Ku, David N.
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 2012, 109 (10) : 2642 - 2650
  • [4] Wall shear over high degree stenoses pertinent to atherothrombosis
    Bark, David L., Jr.
    Ku, David N.
    [J]. JOURNAL OF BIOMECHANICS, 2010, 43 (15) : 2970 - 2977
  • [5] Fluid mechanics of arterial stenosis: Relationship to the development of mural thrombus
    Bluestein, D
    Niu, LJ
    Schoephoerster, RT
    Dewanjee, MK
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1997, 25 (02) : 344 - 356
  • [6] The Platelet and the Biophysical Microenvironment: Lessons from Cellular Mechanics
    Ciciliano, Jordan C.
    Trana, Reginald
    Sakurai, Yumiko
    Lam, Wilbur A.
    [J]. THROMBOSIS RESEARCH, 2014, 133 (04) : 532 - 537
  • [7] Actin-microtubule crosstalk in cell biology
    Dogterom, Marileen
    Koenderink, Gijsje H.
    [J]. NATURE REVIEWS MOLECULAR CELL BIOLOGY, 2019, 20 (01) : 38 - 54
  • [8] Modeling and prediction of flow-induced hemolysis: a review
    Faghih, Mohammad M.
    Sharp, M. Keith
    [J]. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2019, 18 (04) : 845 - 881
  • [9] A Microfluidic Deformability Assessment of Pathological Red Blood Cells Flowing in a Hyperbolic Converging Microchannel
    Faustino, Vera
    Rodrigues, Raquel O.
    Pinho, Diana
    Costa, Elisio
    Santos-Silva, Alice
    Miranda, Vasco
    Amaral, Joana S.
    Lima, Rui
    [J]. MICROMACHINES, 2019, 10 (10)
  • [10] Blood Flow and Cell-Free Layer in Microvessels
    Fedosov, Dmitry A.
    Caswell, Bruce
    Popel, Aleksander S.
    Karniadakis, George Em
    [J]. MICROCIRCULATION, 2010, 17 (08) : 615 - 628