Separation of Long-Lived 108mAg from 152Eu and 60Co Using Polyethylene Glycol Based Aqueous Two Phase Systems

被引:1
作者
Mitra, Sayantani [1 ]
Naskar, Nabanita [2 ]
Lahiri, Susanta [2 ,3 ]
机构
[1] Univ Calcutta, 35,Ballygunge Circular Rd, Kolkata, India
[2] Diamond Harbour Womens Univ, South 24 Parganas, Sarisha, India
[3] Sidho Kanho Birsha Univ, Purulia, India
关键词
Liquid radioactive waste (LRW); Long-lived radioisotopes; Polyethylene glycol (PEG); Aqueous two phase systems (ATPS); RADIONUCLIDES EU-152; EU-154; SELECTIVE SEPARATION; IONIC LIQUID; METAL-IONS; EXTRACTION; ADSORPTION; BEHAVIOR; AG-110M; CS-137; EQUILIBRIUM;
D O I
10.1007/s10953-023-01318-8
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
An environmentally benign aqueous two phase system has been developed for the separation of Ag-108m from Eu-152 and Co-60 using polyethylene glycol/salt system. Twelve salts (nine inorganic, three organic) and PEG 4000 were chosen to form the ATPS out of which, the best separation was observed for 3 mL 2 mol & BULL;dm(-3) K3PO4: 3 mL PEG 4000 followed by 3 mL 2 mol & BULL;dm(-3) Na2SO4: 3 mL PEG 4000. In both cases, silver was preferentially extracted in the PEG rich phase. The separation factors achieved were S-Ag/Co = 2.11 x 10(3) and S-Ag/Eu = 2.79 x 10(2) in the case of 2 mol & BULL;dm(-3) K3PO4: PEG 4000 combination.
引用
收藏
页码:1289 / 1300
页数:12
相关论文
共 52 条
[1]   Kinetic studies of using polyaniline-titanium tungstophosphate in removal of cesium, cobalt, and europium from waste solutions [J].
Abdel-Galil E.A. ;
Khalil M. ;
El-Aryan Y.F. .
Radiochemistry, 2015, 57 (01) :87-91
[2]   Benzil derivative of polyacrylohydrazide as a new sorbent for separation, preconcentration and measurement of silver(I) ion [J].
Absalan, G. ;
Akhond, M. ;
Ghanizadeh, A. Z. ;
Abedi, Z. A. ;
Tamami, B. .
SEPARATION AND PURIFICATION TECHNOLOGY, 2007, 56 (02) :231-236
[3]  
[Anonymous], 1985, THEORY METHODS USES
[4]   Adsorption behavior and kinetics of exchange of Co2+ and Eu3+ ions on polymer composite ion exchanger [J].
Ayoub, R. R. .
SEPARATION SCIENCE AND TECHNOLOGY, 2016, 51 (02) :229-236
[5]   UPTAKE FROM WATER, DEPURATION AND TISSUE DISTRIBUTION OF AG-110M IN A FRESH-WATER FISH, CYPRINUS-CARPIO L [J].
BAUDIN, JP ;
GARNIERLAPLACE, J ;
LAMBRECHTS, A .
WATER AIR AND SOIL POLLUTION, 1994, 72 (1-4) :129-141
[6]   Separation of 97Ru from niobium target using PEG based aqueous biphasic systems [J].
Datta, Arpita ;
Maiti, Moumita ;
Lahiri, Susanta .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 302 (02) :931-937
[7]   Application of PEG based aqueous biphasic systems in extraction and separation of no-carrier-added 183Re from bulk tantalum [J].
Dutta, B. ;
Lahiri, S. ;
Tomar, B. S. .
RADIOCHIMICA ACTA, 2013, 101 (01) :19-26
[8]   Adsorption and Separation of Eu152+154(III) and Co-60(II) Using Cerium(IV) Tungstate [J].
El-Sweify, F. H. ;
Fattah, A. A. Abdel ;
El-Sheikh, R. ;
Aly, S. M. ;
Ghamry, M. A. .
RADIOCHEMISTRY, 2018, 60 (03) :274-280
[9]   Photon emission intensities in the decay of 108mAg and 110mAg [J].
Ferreux, L. ;
Lepy, M. -C. ;
Be, M. -M. ;
Isnard, H. ;
Lourenco, V. .
APPLIED RADIATION AND ISOTOPES, 2014, 87 :101-106
[10]   Ionic liquid-salt based aqueous biphasic system for rapid separation of no-carrier-added 203Pb from proton irradiated natTl2CO3 target [J].
Ghosh, Kaustab ;
Lahiri, Susanta ;
Sarkar, Kangkana ;
Naskar, Nabanita ;
Choudhury, Dibyasree .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 310 (03) :1311-1316