Ex-vivo and in-vivo validation of a novel measuring protocol for guided endodontics

被引:6
|
作者
Torres, A. [1 ,2 ,3 ,5 ]
Dierickx, M. [3 ]
Coucke, W.
Pedano, MS. [3 ]
Lambrechts, P. [3 ]
Jacobs, R. [1 ,2 ,4 ]
机构
[1] Univ Leuven, Fac Med, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Leuven, Belgium
[2] Univ Hosp Leuven, Dept Oral & Maxillofacial Surg, Leuven, Belgium
[3] Katholieke Univ Leuven, Univ Hosp Leuven, Dept Oral Hlth Sci Endodontol, Leuven, Belgium
[4] Karolinska Inst, Dept Dent Med, Stockholm, Sweden
[5] St Raphael Hosp, OMFS IMPATH Res Grp, Kapucijnenvoer 33, B-3000 Leuven, Belgium
关键词
3-Dimensional printing; Accuracy; Cone beam computed tomography; Dental pulp calcification; Guided endodontics; Intraoral scanner; ACCESS CAVITY PREPARATION; PULP CANAL OBLITERATION; ACCURACY; TEETH;
D O I
10.1016/j.jdent.2023.104566
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To (1) validate the use of a post-operative intraoral scan (IOS) versus Cone Beam Computed Tomography (CBCT), gold standard, on its ability to measure the accuracy of guided endodontics, and (2) present clinical data on the accuracy of guided endodontics.Methods: Four models, including 10 extracted teeth each, were created. Forty guided access cavities were planned on dentin to simulate pulp canal obliteration (PCO). Two operators performed guided access cavities. A postoperative CBCT and IOS were acquired. The coronal, apical, and angular deviations were measured with CBCT and IOS. Clinical accuracy was measured using an IOS acquired immediately after drilling the access cavity with the aid of a guide. Data analysis was performed using multiway Anova and corrected for simultaneous hypothesis testing according to Tukey. P & LE; 0.05 was considered statistically significant. Descriptive statistics on the clinical accuracy of guided endodontics were performed.Results: Thirty-eight cavities were assessed with a mean length of 13.8 mm. No statistical difference between operators and methods was found for all parameters (P > 0.05). Thirty-three patients were treated with guided endodontics and measured using an IOS. Results show an average coronal, apical, and angular deviation of 0.2 mm, 0.45 mm, and 1.91 degrees respectively. The average length of the access cavities was 12.5 mm. Conclusions: An IOS can be used to measure the accuracy of guided endodontics.Clinical data showed high accuracy of guided endodontics with a mean apical deviation smaller than 0.5 mm and a mean angular deviation of less than 2 degrees. Clinical significance: The use of an IOS does not involve additional radiation exposure. A safety margin of at least 1 mm around the planned trajectory should be respected when planning the case to minimize the possibility of root perforation.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] X-ray cell tracking: from ex-vivo to in-vivo experiments
    Astolfo, A.
    Schueltke, E.
    Menk, R. -H.
    Hall, C.
    Juurlink, B.
    Arfelli, F.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [42] Sentinel node mapping in colon carcinoma: In-vivo versus ex-vivo approach
    Tuech, JJ
    Pessaux, P
    Di Fiore, F
    Nitu, V
    Lefebure, B
    Colson, A
    Michot, F
    EJSO, 2006, 32 (02): : 158 - 161
  • [43] Ex-Vivo and In-Vivo Assessment of Cyclamen europaeum Extract After Nasal Administration
    Fernandez-Campos, Francisco
    Clares, Beatriz
    Rodriguez-Lagunas, Maria J.
    Jauregui, Olga
    Casals, Isidre
    Calpena, Ana C.
    PHARMACEUTICS, 2019, 11 (09)
  • [44] INTRAMURAL DELIVERY OF MARKER AGENT IN EX-VIVO AND IN-VIVO MODELS USING A NOVEL DRUG-DELIVERY SLEEVE
    KAPLAN, AV
    KERMODE, J
    GRANT, G
    KLEIN, E
    VETTE, RJ
    HINOHARA, T
    SIMPSON, JB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A187 - A187
  • [45] A novel ex-vivo application of RNAi for neuroscience
    Baskin, Louise
    Urschel, Stephanie
    Eiberger, Britta
    BIOTECHNIQUES, 2008, 45 (03) : 338 - 339
  • [46] In-vivo metabolic tumour volume correlation with ex-vivo pathological volume in laryngeal SCC
    Patel, N.
    Tam, H. H.
    Sandison, A.
    Win, Z.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S262 - S262
  • [47] STUDIES ON THE THROMBOGENIC EFFECTS OF RECOMBINANT TISSUE FACTOR - IN-VIVO VERSUS EX-VIVO FINDINGS
    CALLAS, DD
    BACHER, P
    FAREED, J
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 1995, 21 (02): : 166 - 176
  • [48] Micro-needle implantable electrochemical oxygen sensor: ex-vivo and in-vivo studies
    Rivas, Lourdes
    Dulay, Samuel
    Miserere, Sandrine
    Pla, Laura
    Marin, Sergio Berdun
    Parra, Johanna
    Eixarch, Elisenda
    Gratacos, Eduard
    Illa, Miriam
    Mir, Monica
    Samitier, Josep
    BIOSENSORS & BIOELECTRONICS, 2020, 153
  • [49] BIPOLAR CATHETER ABLATION FOR VENTRICULAR TACHYCARDIA IN HUMANS: EX-VIVO DEVELOPMENT AND IN-VIVO EXPERIENCE
    Spears, D. A.
    Sivagangabalan, G.
    Barry, A.
    Farid, T.
    Sevaptsidis, E.
    Masse, S.
    Kusha, M.
    Ha, A.
    Nair, K.
    Downar, E.
    Chauhan, V.
    Harris, L.
    Khan, F.
    Das, M.
    Roshan, J.
    Scott, L.
    Nanthakumar, K.
    CANADIAN JOURNAL OF CARDIOLOGY, 2012, 28 (05) : S383 - S383
  • [50] CHARACTERIZING THE EX-VIVO MECHANICAL PROPERTIES AND CORRESPONDING IN-VIVO IMPACT OF SYNTHETIC UROGYNECOLOGICAL MESHES
    Feola, Andrew J.
    Moalli, Pamela
    Stein, Suzan
    Jallah, Zegbeh
    Shepherd, Jon
    Abramowitch, Steven D.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2011, PTS A AND B, 2011, : 441 - 442