Ex-vivo and in-vivo validation of a novel measuring protocol for guided endodontics

被引:6
|
作者
Torres, A. [1 ,2 ,3 ,5 ]
Dierickx, M. [3 ]
Coucke, W.
Pedano, MS. [3 ]
Lambrechts, P. [3 ]
Jacobs, R. [1 ,2 ,4 ]
机构
[1] Univ Leuven, Fac Med, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Leuven, Belgium
[2] Univ Hosp Leuven, Dept Oral & Maxillofacial Surg, Leuven, Belgium
[3] Katholieke Univ Leuven, Univ Hosp Leuven, Dept Oral Hlth Sci Endodontol, Leuven, Belgium
[4] Karolinska Inst, Dept Dent Med, Stockholm, Sweden
[5] St Raphael Hosp, OMFS IMPATH Res Grp, Kapucijnenvoer 33, B-3000 Leuven, Belgium
关键词
3-Dimensional printing; Accuracy; Cone beam computed tomography; Dental pulp calcification; Guided endodontics; Intraoral scanner; ACCESS CAVITY PREPARATION; PULP CANAL OBLITERATION; ACCURACY; TEETH;
D O I
10.1016/j.jdent.2023.104566
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To (1) validate the use of a post-operative intraoral scan (IOS) versus Cone Beam Computed Tomography (CBCT), gold standard, on its ability to measure the accuracy of guided endodontics, and (2) present clinical data on the accuracy of guided endodontics.Methods: Four models, including 10 extracted teeth each, were created. Forty guided access cavities were planned on dentin to simulate pulp canal obliteration (PCO). Two operators performed guided access cavities. A postoperative CBCT and IOS were acquired. The coronal, apical, and angular deviations were measured with CBCT and IOS. Clinical accuracy was measured using an IOS acquired immediately after drilling the access cavity with the aid of a guide. Data analysis was performed using multiway Anova and corrected for simultaneous hypothesis testing according to Tukey. P & LE; 0.05 was considered statistically significant. Descriptive statistics on the clinical accuracy of guided endodontics were performed.Results: Thirty-eight cavities were assessed with a mean length of 13.8 mm. No statistical difference between operators and methods was found for all parameters (P > 0.05). Thirty-three patients were treated with guided endodontics and measured using an IOS. Results show an average coronal, apical, and angular deviation of 0.2 mm, 0.45 mm, and 1.91 degrees respectively. The average length of the access cavities was 12.5 mm. Conclusions: An IOS can be used to measure the accuracy of guided endodontics.Clinical data showed high accuracy of guided endodontics with a mean apical deviation smaller than 0.5 mm and a mean angular deviation of less than 2 degrees. Clinical significance: The use of an IOS does not involve additional radiation exposure. A safety margin of at least 1 mm around the planned trajectory should be respected when planning the case to minimize the possibility of root perforation.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] High in-vivo accuracy of a novel robotic-arm-assisted system for total knee arthroplasty
    Zaidi, Faseeh
    Goplen, Craig M.
    Fitz-Gerald, Connor
    Bolam, Scott M.
    Hanlon, Michael
    Munro, Jacob T.
    Monk, Andrew P.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2025, 33 (01) : 229 - 238
  • [42] Endometrium imaging using real-time rotational optical coherence tomography imaging system A pilot, prospective and ex-vivo study
    Law, Tracy Sze Man
    Wu, Fangrong
    Xu, Hui
    Wang, Chi Chiu
    Li, Tin Chiu
    MEDICINE, 2019, 98 (44) : e17738
  • [43] A novel automated discontinuous venous blood monitoring system for ex vivo glucose determination in humans
    Schaller, R.
    Feichtner, F.
    Koehler, H.
    Bodenlenz, M.
    Plank, J.
    Wutte, A.
    Mader, J. K.
    Ellmerer, M.
    Hellmich, R.
    Wedig, H.
    Hainisch, R.
    Pieber, T. R.
    Schaupp, L.
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (07) : 2239 - 2245
  • [44] Quantitative Intracranial Atherosclerotic Plaque Characterization at 7T MRI: An Ex Vivo Study with Histologic Validation
    Harteveld, A. A.
    Denswil, N. P.
    Siero, J. C. W.
    Zwanenburg, J. J. M.
    Vink, A.
    Pouran, B.
    Spliet, W. G. M.
    Klomp, D. W. J.
    Luijten, P. R.
    Daemen, M. J.
    Hendrikse, J.
    van der Kolk, A. G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (05) : 802 - 810
  • [45] Evaluation of Dentine Structure Loss after Separated File Retrieval by Three Different Techniques: An Ex-vivo Study
    Abdeen, Mohamed Ashraf
    Plotino, Gianluca
    Hassanien, Ehab El-Sayed
    Turky, Mohammed
    EUROPEAN ENDODONTIC JOURNAL, 2023, 8 (03): : 225 - 230
  • [46] Robotic-Assisted Real-Time Image-Guided: From System Development to Ex Vivo Experiment
    Farouk, Z. I. Bibi
    Jiang, Shan
    Yang, Zhiyong
    Umar, Abubakar
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2023, 48 (03) : 3709 - 3722
  • [47] A comparison in the efficacy of 3D-printed guides versus traditional endodontic access: an ex-vivo study
    Garcia-Sanchez, Alvaro
    Sato, Manuel
    Gargano, Angelica
    Nasir, Myra
    Pita, Afroditi
    Mateos-Moreno, Maria-Victoria
    Perez-Jardon, Alba
    Salgado-Peralvo, angel Orion
    GIORNALE ITALIANO DI ENDODONZIA, 2024, 38 (03): : 54 - 63
  • [48] 3D Printed Temporary Veneer Restoring Autotransplanted Teeth in Children: Design and Concept Validation Ex Vivo
    Al-Rimawi, Ali
    EzEldeen, Mostafa
    Schneider, Danilo
    Politis, Constantinus
    Jacobs, Reinhilde
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (03)
  • [49] To Analyze the Mesiobuccal Root Canal of Maxillary First Molar using Cone Beam Computed Tomography: An Ex-vivo Study
    Vasisth, Diwakar
    Surana, Pratik
    Gupta, Ekta
    Bhargava, Triveni
    Sahoo, Nivedita
    Sonkesriya, Subhash
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S867 - S870
  • [50] Guided access cavity preparation using cone-beam computed tomography and optical surface scans - an ex vivo study
    Buchgreitz, J.
    Buchgreitz, M.
    Mortensen, D.
    Bjorndal, L.
    INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (08) : 790 - 795