Ex-vivo and in-vivo validation of a novel measuring protocol for guided endodontics

被引:6
|
作者
Torres, A. [1 ,2 ,3 ,5 ]
Dierickx, M. [3 ]
Coucke, W.
Pedano, MS. [3 ]
Lambrechts, P. [3 ]
Jacobs, R. [1 ,2 ,4 ]
机构
[1] Univ Leuven, Fac Med, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Leuven, Belgium
[2] Univ Hosp Leuven, Dept Oral & Maxillofacial Surg, Leuven, Belgium
[3] Katholieke Univ Leuven, Univ Hosp Leuven, Dept Oral Hlth Sci Endodontol, Leuven, Belgium
[4] Karolinska Inst, Dept Dent Med, Stockholm, Sweden
[5] St Raphael Hosp, OMFS IMPATH Res Grp, Kapucijnenvoer 33, B-3000 Leuven, Belgium
关键词
3-Dimensional printing; Accuracy; Cone beam computed tomography; Dental pulp calcification; Guided endodontics; Intraoral scanner; ACCESS CAVITY PREPARATION; PULP CANAL OBLITERATION; ACCURACY; TEETH;
D O I
10.1016/j.jdent.2023.104566
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To (1) validate the use of a post-operative intraoral scan (IOS) versus Cone Beam Computed Tomography (CBCT), gold standard, on its ability to measure the accuracy of guided endodontics, and (2) present clinical data on the accuracy of guided endodontics.Methods: Four models, including 10 extracted teeth each, were created. Forty guided access cavities were planned on dentin to simulate pulp canal obliteration (PCO). Two operators performed guided access cavities. A postoperative CBCT and IOS were acquired. The coronal, apical, and angular deviations were measured with CBCT and IOS. Clinical accuracy was measured using an IOS acquired immediately after drilling the access cavity with the aid of a guide. Data analysis was performed using multiway Anova and corrected for simultaneous hypothesis testing according to Tukey. P & LE; 0.05 was considered statistically significant. Descriptive statistics on the clinical accuracy of guided endodontics were performed.Results: Thirty-eight cavities were assessed with a mean length of 13.8 mm. No statistical difference between operators and methods was found for all parameters (P > 0.05). Thirty-three patients were treated with guided endodontics and measured using an IOS. Results show an average coronal, apical, and angular deviation of 0.2 mm, 0.45 mm, and 1.91 degrees respectively. The average length of the access cavities was 12.5 mm. Conclusions: An IOS can be used to measure the accuracy of guided endodontics.Clinical data showed high accuracy of guided endodontics with a mean apical deviation smaller than 0.5 mm and a mean angular deviation of less than 2 degrees. Clinical significance: The use of an IOS does not involve additional radiation exposure. A safety margin of at least 1 mm around the planned trajectory should be respected when planning the case to minimize the possibility of root perforation.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] COMPARISON OF FUNCTION OF EX-VIVO AND IN-VIVO LIVERS
    CUSCHIERI, A
    BAKER, PR
    SHIELDS, R
    BRITISH JOURNAL OF SURGERY, 1972, 59 (11) : 901 - +
  • [2] Ex-vivo systems for neuromodulation: A comparison of ex-vivo and in-vivo large animal nerve electrophysiology
    Ribeiro, Mafalda
    Andreis, Felipe R.
    Jabban, Leen
    Nielsen, Thomas G. N. dS.
    Smirnov, Sergey, V
    Lutteroth, Christof
    Proulx, Michael J.
    Rocha, Paulo R. F.
    Metcalfe, Benjamin
    JOURNAL OF NEUROSCIENCE METHODS, 2024, 406
  • [3] Development of a novel instrument for ex-vivo and in-vivo real-time analysis
    Fournier, Isabelle
    Fatou, Benoit
    Wisztorski, Maxence
    Focsa, Cristian
    Ziskind, Michael
    Salzet, Michel
    JOURNAL OF BIOTECHNOLOGY, 2015, 208 : S10 - S10
  • [4] ASSESSMENT OF HEPATOBILIARY FUNCTION IN-VIVO AND EX-VIVO IN THE RAT
    HANDLER, JA
    KOSSOR, DC
    GOLDSTEIN, RS
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 1994, 31 (01) : 11 - 19
  • [5] Atypical fibroxanthoma: in-vivo and ex-vivo confocal features
    Pampena, Riccardo
    Peccerillo, Francesca
    Piana, Simonetta
    Paolino, Giovanni
    Mercuri, Santo R.
    Pellacani, Giovanni
    Longo, Caterina
    ITALIAN JOURNAL OF DERMATOLOGY AND VENEREOLOGY, 2021, 156 (06) : 41 - 42
  • [6] Electromagnetic tracking for CT-guided spine interventions: phantom, ex-vivo and in-vivo results
    Philipp Bruners
    Tobias Penzkofer
    Markus Nagel
    Robert Elfring
    Nina Gronloh
    Thomas Schmitz-Rode
    Rolf W. Günther
    Andreas H. Mahnken
    European Radiology, 2009, 19 : 990 - 994
  • [7] Electromagnetic tracking for CT-guided spine interventions: phantom, ex-vivo and in-vivo results
    Bruners, Philipp
    Penzkofer, Tobias
    Nagel, Markus
    Elfring, Robert
    Gronloh, Nina
    Schmitz-Rode, Thomas
    Guenther, Rolf W.
    Mahnken, Andreas H.
    EUROPEAN RADIOLOGY, 2009, 19 (04) : 990 - 994
  • [8] Fetoscopic Panorama Reconstruction: Moving from Ex-vivo to In-vivo
    Gaisser, Floris
    Peeters, Suzanne H. P.
    Lenseigne, Boris
    Jonker, Pieter P.
    Oepkes, Dick
    MEDICAL IMAGE UNDERSTANDING AND ANALYSIS (MIUA 2017), 2017, 723 : 581 - 593
  • [9] INFRARED SPECTROSCOPIC INVESTIGATION OF IN-VIVO AND EX-VIVO HUMAN NAILS
    SOWA, MG
    WANG, J
    SCHULTZ, CP
    AHMED, MK
    MANTSCH, HH
    VIBRATIONAL SPECTROSCOPY, 1995, 10 (01) : 49 - 56
  • [10] Comparison of in-vivo and ex-vivo Dielectric Properties of Biological Tissues
    Salahuddin, Saqib
    La Gioia, Alessandra
    Elahi, Muhammad Adnan
    Porter, Emily
    O'Halloran, Martin
    Shahzad, Atif
    2017 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS (ICEAA), 2017, : 582 - 585