Ex-vivo and in-vivo validation of a novel measuring protocol for guided endodontics

被引:6
|
作者
Torres, A. [1 ,2 ,3 ,5 ]
Dierickx, M. [3 ]
Coucke, W.
Pedano, MS. [3 ]
Lambrechts, P. [3 ]
Jacobs, R. [1 ,2 ,4 ]
机构
[1] Univ Leuven, Fac Med, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Leuven, Belgium
[2] Univ Hosp Leuven, Dept Oral & Maxillofacial Surg, Leuven, Belgium
[3] Katholieke Univ Leuven, Univ Hosp Leuven, Dept Oral Hlth Sci Endodontol, Leuven, Belgium
[4] Karolinska Inst, Dept Dent Med, Stockholm, Sweden
[5] St Raphael Hosp, OMFS IMPATH Res Grp, Kapucijnenvoer 33, B-3000 Leuven, Belgium
关键词
3-Dimensional printing; Accuracy; Cone beam computed tomography; Dental pulp calcification; Guided endodontics; Intraoral scanner; ACCESS CAVITY PREPARATION; PULP CANAL OBLITERATION; ACCURACY; TEETH;
D O I
10.1016/j.jdent.2023.104566
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To (1) validate the use of a post-operative intraoral scan (IOS) versus Cone Beam Computed Tomography (CBCT), gold standard, on its ability to measure the accuracy of guided endodontics, and (2) present clinical data on the accuracy of guided endodontics.Methods: Four models, including 10 extracted teeth each, were created. Forty guided access cavities were planned on dentin to simulate pulp canal obliteration (PCO). Two operators performed guided access cavities. A postoperative CBCT and IOS were acquired. The coronal, apical, and angular deviations were measured with CBCT and IOS. Clinical accuracy was measured using an IOS acquired immediately after drilling the access cavity with the aid of a guide. Data analysis was performed using multiway Anova and corrected for simultaneous hypothesis testing according to Tukey. P & LE; 0.05 was considered statistically significant. Descriptive statistics on the clinical accuracy of guided endodontics were performed.Results: Thirty-eight cavities were assessed with a mean length of 13.8 mm. No statistical difference between operators and methods was found for all parameters (P > 0.05). Thirty-three patients were treated with guided endodontics and measured using an IOS. Results show an average coronal, apical, and angular deviation of 0.2 mm, 0.45 mm, and 1.91 degrees respectively. The average length of the access cavities was 12.5 mm. Conclusions: An IOS can be used to measure the accuracy of guided endodontics.Clinical data showed high accuracy of guided endodontics with a mean apical deviation smaller than 0.5 mm and a mean angular deviation of less than 2 degrees. Clinical significance: The use of an IOS does not involve additional radiation exposure. A safety margin of at least 1 mm around the planned trajectory should be respected when planning the case to minimize the possibility of root perforation.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Reproducibility of an intraoral scanner: A comparison between in-vivo and ex-vivo scans
    Sun, LiJun
    Lee, Jin-Sol
    Choo, Hyun-Hee
    Hwang, Hyeon-Shik
    Lee, Kyung-Min
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2018, 154 (02) : 305 - 310
  • [2] Guided endodontics: accuracy of access cavity preparation and discrimination of angular and linear deviation on canal accessing ability-an ex vivo study
    Su, Yinghui
    Chen, Chenghui
    Lin, Chiahua
    Lee, Huina
    Chen, Kerkong
    Lin, Yenkun
    Fuhsiung Chuang
    BMC ORAL HEALTH, 2021, 21 (01)
  • [3] Lumen enhancement influences absolute noncalcific plaque density on multislice computed tomography coronary angiography: ex-vivo validation and in-vivo demonstration
    Cademartiri, Filippo
    Runza, Giuseppe
    Palumbo, Alessandro
    Maffei, Erica
    Martini, Chiara
    McFadden, Eugene
    Somers, Pamela
    Knaapen, Michiel
    Verheye, Stefan
    Weustink, Annick C.
    Mollet, Nico R.
    de Feyter, Pim J.
    Hamers, Ronald
    Bruining, Nico
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2010, 11 (05) : 337 - 344
  • [4] Loss of surface enamel after bracket debonding: An in-vivo and ex-vivo evaluation
    Pont, Huib Berghauser
    Oezcan, Mutlu
    Bagis, Bora
    Ren, Yijin
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 138 (04) : 387 - 389
  • [5] Mechanistic efficacy assessment of selected novel methanimine derivatives against vincristine induced Neuropathy: In-vivo, Ex-vivo and In-silico correlates
    Khan, Jawad
    Ali, Gowhar
    Khurshid, Asma
    Saeed, Aamer
    Ahmad, Sajjad
    Ullah, Najeeb
    Khan, Ashrafullah
    Sewell, Robert D.
    Zakria, Muhammad
    INTERNATIONAL IMMUNOPHARMACOLOGY, 2022, 112
  • [6] Guided endodontics: accuracy of access cavity preparation and discrimination of angular and linear deviation on canal accessing ability—an ex vivo study
    Yinghui Su
    Chenghui Chen
    Chiahua Lin
    Huina Lee
    Kerkong Chen
    Yenkun Lin
    Fuhsiung Chuang
    BMC Oral Health, 21
  • [7] Guided Endodontics: Volume of Dental Tissue Removed by Guided Access Cavity Preparation-An Ex Vivo Study
    Loureiro, Marco Antonio Z.
    Elias, Marcela R. A.
    Capeletti, Lucas R.
    Silva, Julio A.
    Siqueira, Patricia C.
    Chaves, Gustavo S.
    Decurcio, Daniel A.
    JOURNAL OF ENDODONTICS, 2020, 46 (12) : 1907 - 1912
  • [8] Guided endodontics versus conventional access cavity preparation: an ex vivo comparative study of substance loss
    Hildebrand, Hauke
    Leontiev, Wadim
    Krastl, Gabriel
    Weiger, Roland
    Dagassan-Berndt, Dorothea
    Buerklein, Sebastian
    Connert, Thomas
    BMC ORAL HEALTH, 2023, 23 (01)
  • [9] An overview on the veracity of intraoral digital scanning system and utilization of iTero scanner for analyzing orthodontic study models both In-Vivo and Ex-Vivo
    Jabri, M. A.
    Wu, S.
    Pan, Y.
    Wang, L.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2021, 24 (01) : 1 - 7
  • [10] CT Fluoroscopy-Guided Lung Biopsy with Novel Steerable Biopsy Canula: Ex-Vivo Evaluation in Ventilated Porcine Lung Explants
    Schaefer, Philipp J.
    Fabel, Michael
    Bolte, Hendrik
    Schaefer, Fritz K. W.
    Jahnke, Thomas
    Heller, Martin
    Lammer, Johannes
    Biederer, Juergen
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (04) : 828 - 834